My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5901 23RD DR W ZAP ENERGY 2025-04-23
>
Address Records
>
23RD DR W
>
5901
>
ZAP ENERGY
>
5901 23RD DR W ZAP ENERGY 2025-04-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/23/2025 3:48:13 PM
Creation date
2/14/2025 8:21:33 AM
Metadata
Fields
Template:
Address Document
Street Name
23RD DR W
Street Number
5901
Tenant Name
ZAP ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
579
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
This calculator provided voltage drop calculations in three formats (Point to Point, End of Line, and Load Centering). <br /> Make sure that you know what method is accepted by,and the results do not exceed the limits set by the respective jurisdiction <br /> Point to Point Method End of Line Method Load Centering Method <br /> Project Name ZAP ENERGY CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS <br /> Date 6/30/21 <br /> Circuit Number NAC 3 Totals Voltage Totals Voltage Totals Voltage <br /> Area Covered SOUTH OFFICES NOTIFICATION Current Distance Drop Current Distance Drop Current Distance Drop <br /> Nominal System Voltage, 24 - 1.244 435 3.06 1.244 435 5.292 1.244 435 2.646 <br /> Minimum Device Voltage 16 End of Line Voltage 20.94 End of Line Voltage 18.71 End of Line Voltage 21.35 <br /> Total Circuit Current 1.244 Wire Ohm's - Percent Drop 12.73% Percent Drop 22.05% Percent Drop 11.03% <br /> Gauge Per 1000 End of Line and Load Centering Methods use only the wire guage for the first device to source <br /> Distance from source to 1st device 40 16 4.89 Standard Wire Resistance in Ohms per 1000 feet. <br /> Wire Gauge for balance of circuit 16 4.89 1 18=7.771 16=4.891 14=3.071 12=1.981 10=1.241 <br /> Enter current in amps. Distance 18-14 Awgi=Solid Conductors 12-10 Awg= Stranded Conductors <br /> .150= 150 ma from Voltage Notes: <br /> Device Device previous At Drop from Percent Wire resistance is doubled in the calculations for two wires (Positive and Negative) <br /> Number Current device Device source Drop The voltage calculated to the last device in any method must not be lower then <br /> Device 1 0.072 40 23.51 0.487 2.03% the manufactures listed minimum operating voltage(IE: rated operating voltage 20-32 VDC). <br /> Device 2 0.072 65 22.77 1.232 5.13% <br /> Device 3 0.190 30 22.45 1.554 6.48% Device Manufacturer POTTER Device Manufacturer <br /> Device 4 0.072 35 22.13 1.866 7.77% Current I Current <br /> Device 5 0.190 40 21.81 2.194 9.14% CEILING MOUNT @Rated @Rated <br /> Device 6 0.095 45 21.52 2.479 10.33% Model# Candela Voltage Model# Candela Voltage <br /> Device 7 0.072 35 21.33 2.668 11.12% Strobe 15 0.072 <br /> Device 8 0.072 15 21.26 2.739 11.41% Strobe 30 0.101 <br /> Device 9 0.095 25 21.16 2.839 11.83% Strobe 75 0.167 <br /> Device 10 0.124 45 21.02 _ 2.977 12.40% Strobe 95 0.2 _ <br /> Device 11 0.095 25 20.98 3.023 12.60% Horn -- 0.023 <br /> Device 12 0.095 35 20.94 3.056 12.73% <br /> END 20.94 3.056 12.73% <br /> END 20.94 3.056 12.73% <br /> END 20.94 3.056 12.73% <br /> END 20.94 3.056 12.73% <br /> END 20.94 3.056 12.73% <br /> END 20.94 3.056 12.73% <br /> END 20.94 3.056 12.73% 1 <br /> END 20.94 3.056 12.73% 7 ___ <br /> i <br /> Totals 1.244 435 End of Line Voltage 20.94 <br />
The URL can be used to link to this page
Your browser does not support the video tag.