My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1200 INDUSTRY ST 2025-03-24
>
Address Records
>
INDUSTRY ST
>
1200
>
1200 INDUSTRY ST 2025-03-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 11:30:51 AM
Creation date
2/26/2025 11:54:49 AM
Metadata
Fields
Template:
Address Document
Street Name
INDUSTRY ST
Street Number
1200
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
101
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S. All lumber in contact with masonry or concrete is to be pressure treated except for plywood, <br /> U.O.N. <br /> T. The wood blocking shown in the details and sections are graphic representations only. Solid <br /> continuous blocking shall be provided to match roof insulation at the thickest point and maintain <br /> the same elevation for the entire perimeter of the roof unless otherwise indicated. <br /> U. Do not install wood nailers ahead of new roofing work. Only install nailers that can be covered <br /> the same day. <br /> V. Counter sink all fasteners for wood blocking. <br /> W. All existing wood blocking to remain is to be fastened with additional screws as per FM 1-49 <br /> placement. Pre-drill and set new securement using epoxy shields in masonry units and TEK <br /> fasteners in steel as required for positive attachment. Consult with professional fastener <br /> companies like Hilti, Triangle fasteners, etc. for additional guidance. <br /> X. All roof curbs greater than 24"wide and set perpendicular to the roof slope shall be required to <br /> receive a tapered saddle to promote positive water flow. <br /> Y. The new roof system is to incorporate insulation attachment to incorporate wind pressure <br /> enhancements at the field, perimeter, and corners in accordance with ASCE 7 as defined by <br /> local codes. <br /> Z. Premanufactured tapered insulation units are to be used at roof sumps, crickets, and saddles to <br /> promote positive water flow to the roof drains. Field-fabricated tapered units may be used if <br /> approved during the submittal process. <br /> AA. All roof membrane details are to follow roof manufacturer's details for a 30-year warranty <br /> whether or not a 30-year warranty is required. <br /> BB. Install manufacturers pre-fabricated inside and outside flashing corners following the <br /> recommendations and requirements of the roofing membrane manufacturer. Provide "t-joint <br /> covers" at the base of all vertical flashing /field seam intersections. <br /> CC. Secure top edge or termination of all membrane flashing using an aluminum termination bar <br /> secured 12-inches o.c., max. (detail shown on the project plans), and within 2-inches of each <br /> end. Prior to termination bar installation, install manufacturers recommended compression <br /> sealant behind flashing where termination bar will be placed. Apply manufacturers' approved <br /> sealant to the top edge of flashing and termination bar after proper mechanical attachment. <br /> DD. Extend all new membrane flashing up and over perimeter parapet wall under metal edge cleat <br /> to cover beyond the exterior of the wood nailer/ parapet transition by 1 '/2" minimum. <br /> EE. Extend all new membrane flashing under roof metal edge to cover beyond the exterior of the <br /> wood nailer/parapet transition by 1 '/2" minimum. <br /> FF. Provide walkpads at the base and top of ladders, stairs, at roof access doors, at other roof <br /> access points, and at all serviceable mechanical unit doors or access panels. <br /> GG. The use of"penetration pans" or"pitch pockets" is not permitted unless the geometry of <br /> multiple penetrations is not sufficient for field wrapping and without prior owner approval. <br /> HH. All roof deck penetrations and perimeter edges of the roof section will be required to receive a <br /> reinforced fire-stop sealant to prevent air and moisture drive into the new roof system. <br /> II. All wood supports for electrical conduit and gas line supports must be replaced with new <br /> Caddy, Miro, or equal premanufactured units to accommodate the new roof system. <br /> JJ. All perimeter edge metal profiles must meet ANSI/SPRI ES-1 wind design requirements for FM <br /> Global and included in the membrane manufacturer's warranty for the minimum of 30 years <br /> including wind and performance. <br /> KK. All new metal flashings for RTU counterflashing, cool stack base flashings, rain hoods, <br /> miscellaneous vertical wall flashing terminations, perimeter wall counterflashing, reglet metal, <br /> SEA00511 / Prologis - SEA00511 01 1000 - 5 Summary <br /> - FY24- Everett 1 - Capital <br /> Roofing Project <br />
The URL can be used to link to this page
Your browser does not support the video tag.