My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1200 INDUSTRY ST 2025-03-24
>
Address Records
>
INDUSTRY ST
>
1200
>
1200 INDUSTRY ST 2025-03-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 11:30:51 AM
Creation date
2/26/2025 11:54:49 AM
Metadata
Fields
Template:
Address Document
Street Name
INDUSTRY ST
Street Number
1200
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
101
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1. Fast(tm)Adhesive as manufactured by Carlisle-Syntec, Inc., P.O. Box 7000, Carlisle, PA <br /> 17013. Telephone: (800)-4-SYNTEC; http//www.carlisle-syntec.com. <br /> 2. S.O. Spray Insulation adhesive as manufactured by Firestone Building Products <br /> Company, 525 Congressional Blvd., Carmel, Indiana 46032. Telephone: 1-800-428-4442, <br /> http//www.firestonebpco.com <br /> 3. OlyBond@ Adhesive Fastener as manufactured by Olympic Manufacturing Group, P.O. <br /> Box 508, 153 Bowles Road, Agawam, MA 01001, 413.789.0252 (phone) 800.633.3800 <br /> (phone)413.789.1069 (fax) e-mail: info@olyfast.com www.olyfast.com <br /> 4. or approved substitute. <br /> 2.07 FASTENERS: <br /> A. General: All fasteners, including but not limited to those used for attaching rigid insulation <br /> board, anchor bars, and sheet metal flashings shall be approved by the manufacturer. <br /> Contractor shall submit a letter of approval, listing all fasteners being used on the project and <br /> that they are acceptable for the guaranteed roof system specified. <br /> B. Insulation to Deck: <br /> 1. Fastener: No 12 (or better) corrosion resistant, heavy duty deck fasteners and 2-7/8" min. <br /> diameter Galvalume (TM) metal plate approved by the roofing manufacturer and <br /> acceptable with FM Global approved systems. <br /> 2. For the plate bonded system, provide polymer-coated metal plates approved for FMG <br /> rated systems. <br /> 3. The fastener length shall be sufficient to penetrate the steel deck 3/4" minimum. <br /> C. Roofing Material to Concrete or Masonry: Concrete nails with an integral flat cap (1 inch <br /> minimum diameter).or coated fasteners designed for concrete deck attachment <br /> D. Sheet Metal to Wood (Buried by Roofing): <br /> 1. FS FF-N-105B (3)Type II, Style 20, roofing nails, galvanized steel wire, flat head, <br /> diamond point, round barbed shank. <br /> 2. Length sufficient to penetrate wood blocking 1-1/4". <br /> 3. Maximum spacing shall be 4" o.c. <br /> E. Sheet Metal to Wood (Exposed): Hex head screws with EPDM/stainless steel sealing bearing <br /> washers. Length sufficient to penetrate wood 1-1/4". Maximum spacing shall be 18" on center. <br /> F. Hook Strips to Wood: <br /> 1. Annular threaded corrosion resistant nails with 3/16" minimum flat head. Nail shall <br /> penetrate wood a minimum of 1-1/4", spaced a maximum of 6" on center. <br /> 2. 8 corrosion resistant screws. The screw shall penetrate the wood a minimum of 3/4," <br /> spaced a maximum of 6" on center. <br /> G. Anchor Bars, Reglets Or Sheet Metal to Concrete: <br /> 1. Pin driven, lead encased, expansion anchors with sealing/bearing washer. Zamac <br /> fastener or equal. <br /> H. Drawband: <br /> 1. Gold Seal stainless steel worm gear clamp by Murray Corp., Cockeysville, MD. <br /> 2. Power-Seal stainless steel worm drive clamps by Breeze Clamp Co., Saltsburg, PA. <br /> PART 3 - EXECUTION <br /> 3.01 VERIFICATION OF CONDITIONS: <br /> A. Layout: Verify layout of Work before beginning installation. <br /> B. Existing conditions: Examine substrate before beginning installation. Verify penetrations, <br /> nailers, curbs, and necessary equipment have been installed properly, with adequate <br /> clearances, heights, and do not sway or move. <br /> C. Surfaces: Verify concrete surfaces are smooth, free of major defects, cured and dry. <br /> SEA00511 / Prologis - SEA00511 07 5400 - 7 THERMOPLASTIC MEMBRANE <br /> - FY24- Everett 1 - Capital ROOF SYSTEM <br /> Roofing Project <br />
The URL can be used to link to this page
Your browser does not support the video tag.