My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3006 RUCKER AVE PORT GARDNER BAY WINERY 2025-04-07
>
Address Records
>
RUCKER AVE
>
3006
>
PORT GARDNER BAY WINERY
>
3006 RUCKER AVE PORT GARDNER BAY WINERY 2025-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 10:28:39 AM
Creation date
3/4/2025 12:41:04 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3006
Tenant Name
PORT GARDNER BAY WINERY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements • • of <br /> 2018 WSEC Requirements for Commercial Buildings including Group R2, R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> C403.3.5 Dedicated outdoor air For buildings with occupancies required to <br /> C403.3.5.4 systems comply with the DOAS provisions per Table <br /> C403.3.5,identify on plans all occupancies in <br /> the building and indicate which occupied <br /> spaces are required to have ventilation air <br /> delivered by a DOAS;or exception applied <br /> If natural ventilation exception is applied, <br /> identify these spaces on plans;indicate <br /> operable window area complies with IMC <br /> Section 402;provide documentation <br /> describing how required ventilation will be <br /> provided during all occupied hours,including <br /> during inclement weather <br /> If high efficiency VAV exception is applied, <br /> identify these spaces on plans;refer to Single <br /> Zone VAV section for Groups A-1,A-2 and <br /> A-3 occupancy classifications,or Multiple <br /> Zone VAV for other than Groups A-1,A-2 <br /> and A-3(per Table C403.3.5) <br /> If compliance with the DOAS provisions is <br /> deemed to be impractical,provide <br /> documentation that demonstrates the alternate <br /> design strategy applied that achieves a <br /> comparable level of energy efficiency,as pre- <br /> approved by the AHJ <br /> Refer to Requirements List section after <br /> Multiple-Zone Air Systems for High <br /> Efficiency Multiple-Zone VAV Systems <br /> exception to C403.3.5 DOAS <br /> Refer to Requirements List section after High <br /> Efficiency Multiple-Zone Air Systems for <br /> High Efficiency Single-Zone VAV Systems <br /> exception to C403.3.5 DOAS <br /> C403.3.5.1 DOAS energy For all DOAS systems,indicate exhaust air <br /> recovery method and ER method and basis of rated effectiveness <br /> effectiveness (sensible or latent);indicate Z 60%sensible or <br /> >50%enthalpy ER effectiveness based on <br /> delta between outdoor air and return air <br /> enthalpies at design conditions;or exception <br /> applied <br /> If applying exception for DCV,identify <br /> occupant load in space and airflow control <br /> configured to reduce ventilation rate by>_ <br /> 50%when occupancy is less than design <br /> occupancy <br /> C403.3.5.1 DOAS fan power For DOAS with total system fan hp<5 hp, <br /> indicate total system fan power does not <br /> exceed 1 watt per cfm <br /> For DOAS with total system fan hp>_5 hp, <br /> indicate total system fan power complies with <br /> fan power limitation per Section C403.8.1 <br /> Page 3125 <br />
The URL can be used to link to this page
Your browser does not support the video tag.