KAISER PERMANENTE Site Prep #1 Electrical Service
<br />ASC & Clinic (HUB) March 18, 2020
<br />Everett, WA Project No. 19.05002.00
<br />below masonry or concrete construction, earthwork/trenches, within unheated
<br />shelters, crawl spaces or enclosures.
<br />10. Wiring: All wires, raceways, fittings, conductors, connectors, tape, junction and
<br />outlet boxes, connectors, splices, and all other items necessary and/or required in
<br />connection with such work.
<br />11. Raceway: All raceways, conduit, fittings, hangers, supports, sleeves, etc.
<br />1.3 GENERAL REQUIREMENTS
<br />A. Examine the Drawings, specifications and other Contract Documents relating to the Work
<br />and the work of all trades and become fully informed as to the extent and character of work
<br />required. Coordinate all work with that of others to ensure proper and complete installation
<br />of all materials, equipment and supports. It is the intent of the drawings, specifications and
<br />related contract Documents to provide a complete working installation of all systems and
<br />equipment called for, in proper operating condition, finished, tested and ready for its
<br />intended use (hereinafter "Design Intent"). Provide all items not specifically shown on the
<br />drawings, called for in the specifications or related Contract Documents, but required to
<br />conform to the labor, material and equipment to achieve the Design Intent and all
<br />scaffolding, access provisions, tools, appliances, consumables, fees, permits and licenses,
<br />debris removal/disposal, supervision and labor, including required start-up, check-out and
<br />training to provide complete and fully operable systems in full compliance with the Contract
<br />Documents.
<br />B. Before submitting a bid and prior to the start of work, Contractor shall examine all conditions
<br />relating to the Work, including that associated with the work of other trades upon which
<br />Contractor's work may rely or otherwise depend, to achieve the Design Intent, in
<br />accordance with the best trade practices, workmanship and highest quality product
<br />installation, taking into account the sequence of the work, delivery, storage and hoisting
<br />requirements, requirements for access, testing and temporary services and all other site
<br />limitations and project complexities. Report to the Architect/Engineer any conditions which
<br />might prevent installation of materials and/or equipment in the manner intended by the
<br />Contract Documents or contrary to applicable codes, standards or regulations.
<br />C. No consideration or allowance will be granted for any alleged misunderstanding of
<br />materials, equipment or components to be furnished or work to be done; it being agreed
<br />that tender of proposal carries with it agreement to items, terms and conditions required by
<br />the Contract Documents.
<br />D. Site Visit: Visit the site and verify the exact conditions relating to the work and obtain such
<br />information as may be necessary to present a complete and comprehensive bid. No
<br />allowance will be made for any extra expense due to Contractor's failure to make such a
<br />visit and reasonably verify all actual/existing conditions. In the event of a conflict between
<br />existing conditions and the requirements of the Contract Documents, perform the
<br />necessary work to conform to Design Intent. The Owner or his representative will be the
<br />sole individual to interpret the intent of the Drawings in the event of a conflict between (1)
<br />existing conditions and those shown on the drawings, or (2) quality of existing material and
<br />quality of material indicated on the drawings or in the specifications. Wherever a conflict
<br />such as this occurs, the higher standard shall prevail.
<br />1.4 SPECIAL REQUIREMENTS
<br />A. When applicable, Contractor acknowledges the ongoing operations of the Owner at or in
<br />close proximity to the Project and agrees to coordinate the timing of the Work with the
<br />Owner's ongoing operations; perform the Work in a manner that minimizes or eliminates
<br />an adverse impact upon the Owner's ongoing operations; confine operations at the site to
<br />areas approved by Owner, permitted by law, permits and the Contract Documents; comply
<br />BASIC ELECTRICAL REQUIREMENTS 2601 00 - 2
<br />
|