My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Colacurcio Brothers, Inc. 2/26/2025
>
Contracts
>
10 Years Then Transfer to State Archivist
>
2025
>
Colacurcio Brothers, Inc. 2/26/2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/12/2025 4:09:29 PM
Creation date
3/12/2025 3:44:09 PM
Metadata
Fields
Template:
Contracts
Contractor's Name
Colacurcio Brothers, Inc.
Approval Date
2/26/2025
Council Approval Date
3/12/2025
End Date
9/9/2025
Department
Transit
Department Project Manager
Brad Chenoweth
Subject / Project Title
Everett Mall Bus Platform
Tracking Number
0004733
Total Compensation
$1,992,715.50
Contract Type
Capital Contract
Contract Subtype
Capital Construction Contracts and Change Orders
Retention Period
10 Years Then Transfer to State Archivist
Imported from EPIC
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1121
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
CITY OF EVERETT SPECIAL PROVISIONS <br /> <br /> <br /> <br /> <br /> Division 2 <br />Everett Mall Bus Platform Earthwork December 2024 <br />WO No – MALLSTN/24462 SP-114 <br />2. Secure permission from and comply with all requirements of the City’s water <br />utility before obtaining water from the fire hydrants. Notify the Engineer of City’s <br />permission as soon as granted. <br />3. Use hydrant wrenches only to open hydrants. Make certain the hydrant valve is <br />fully open because "cracking" the hydrant valve causes damage to the hydrant <br />valve. Provide an approved auxiliary valve on the outlet line for control purposes. <br />Close fire hydrant valves slowly to avoid a surge in the system that creates <br />excess pressure on water lines. Carefully note the importance of following these <br />directions. <br />4. If Contractor's employees use the wrong wrench to open a hydrant causing <br />damage the hydrant valve stem or operating nut or both, the Contractor shall be <br />responsible for costs associated with repairing the damaged hydrant valve stem <br />or operating nut or both. Immediately notify the City’s water utility so that the <br />damage can be repaired as quickly as possible. <br />5. Notify City water utility immediately upon completing the use of the hydrants so <br />the hydrants may be inspected for possible damage. City water utility will repair <br />damage resulting from the use of the hydrants by the Contractor. Contractor <br />shall be responsible for repair cost and cost, if necessary, shall be withheld from <br />the final payment to the Contractor. <br />6. City water utility will fine Contractor for violation of these requirements. <br />Contractor shall also be liable for damage suits resulting from malfunctioning of <br />Contractor damaged fire hydrants not being operational in the event of fire. <br />7. There will be no charge for the volume of water used. <br />2-07.4 Measurement <br />Revise 2-07.4 to read as follows: <br />Water will not be measured. <br />2-07.5 Payment <br />Revise 2-07.5 to read as follows: <br />All costs for the Work described in Section 2-07 shall be included with the Work with no <br />direct compensation made. <br />2-09 STRUCTURE EXCAVATION <br />2-09.2 Materials <br />Supplement 2-09.2 by adding the following at end of the materials list: <br />Foundation Material Class A or B 9-03.17 Standard Specifications <br />2-09.3 Construction Requirements <br />2-09.3(1) General Requirements <br />2-09.3(1)C Removal of Unstable Base Material <br />Delete all paragraphs in 2-09.3(1)C and substitute the following: <br />When the material at the bottom of an excavation is not stable enough to support <br />the Structure, the Contractor shall excavate below grade to the depth required by <br />the Engineer and replace the unstable material with Foundation Material Class A <br />or B.
The URL can be used to link to this page
Your browser does not support the video tag.