My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7826 RAINIER DR MIKI'S LOVING CARE 2025-04-17
>
Address Records
>
RAINIER DR
>
7826
>
MIKI'S LOVING CARE
>
7826 RAINIER DR MIKI'S LOVING CARE 2025-04-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2025 8:25:10 AM
Creation date
3/13/2025 10:55:31 AM
Metadata
Fields
Template:
Address Document
Street Name
RAINIER DR
Street Number
7826
Tenant Name
MIKI'S LOVING CARE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Drew Martin <br /> From: Drew Martin <br /> Sent: Tuesday, May 3, 2022 3:45 PM <br /> To: sorinsJanitorial@yahoo.com' <br /> Subject: City of Everett Permit Services: 7826 Rainier Drive (B2204-011) - First Building Intake <br /> Review <br /> Attachments: SnoCo Field Assessor Record-7826 Rainier Drive.pdf; 7826 Rainier Drive_Redfin Photos c <br /> 10-30-2021 &Google Street View c. Present.pdf, 2018 IRC-Typical Code References_ <br /> 04-12-2021.docx; CoE_Residential Drawing Prepa ratio n_Edited 09-27-2021.pdf <br /> Hello, Sorin. <br /> Your application has been received and a permit set up. However, the submitted documents are not <br /> sufficiently developed for us to perform a comprehensive review at this time. The Planning Department has <br /> also determined that additional information is required; they will issue a comment letter separately. <br /> Information is attached to provide guidance. Construction-level documents should be submitted for <br /> review. Two complete sets of the revised drawings should be submitted to replace the previously submitted <br /> drawing sets. Preliminary comments are provided below to assist in preparing the drawings, but these are not <br /> intended to provide a comprehensive review. The resubmittal documents should include an itemized <br /> response letter clarifying how the review comments below have been addressed. Depending on your <br /> experience with the adopted codes and preparing documents, we recommend consulting with a design <br /> professional to assist you. <br /> Intake Review Comments: <br /> 1. The project should specify the applicable building codes, including but not limited to the 2018 IRC, 2018 <br /> WSEC, and the 2018 IBC. See Section R106.1.1 and EMC Section 16.005.030. <br /> 2. The submitted drawings appear to include prior unpermitted work, including but not limited to modifying <br /> the interior of the building, attaching the detached shed to the main house, and adding a ramp. The <br /> existing conditions shown in the drawings are not consistent with the available City of Everett and <br /> Snohomish County records. A copy of the old SnoCo Field Assessor record is attached; note that the SnoCo <br /> records only provide a record of the building condition for the purpose of assessing taxes and do not <br /> substantiate a permitted condition. The drawings are also not consistent with photography available on <br /> Google Earth and the real-estate website Redfin.com. The drawings should be revised to show all previous <br /> unpermitted work as new work; all new work is required to comply with the current code <br /> requirements. Alternatively, the drawings should show the removal of unpermitted work and restoration <br /> of the building to its previous legally permitted condition. See IRC Sections R102.7.1, R105.1, and R113.1. <br /> 3. The house is subject to Code Enforcement action per File No. CE22-0322. The drawings to not provide <br /> sufficient information to address the unpermitted conditions and should be revised. See IRC Section <br /> R105.1 and R113.2. <br /> i <br />
The URL can be used to link to this page
Your browser does not support the video tag.