My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7826 RAINIER DR MIKI'S LOVING CARE 2025-04-17
>
Address Records
>
RAINIER DR
>
7826
>
MIKI'S LOVING CARE
>
7826 RAINIER DR MIKI'S LOVING CARE 2025-04-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2025 8:25:10 AM
Creation date
3/13/2025 10:55:31 AM
Metadata
Fields
Template:
Address Document
Street Name
RAINIER DR
Street Number
7826
Tenant Name
MIKI'S LOVING CARE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
the selected credits should be included in the drawings. The performance requirements for the selected <br /> credits should be specified. <br /> 15. The project requires a whole house ventilation system per IRC Section R303.4. The drawings should show <br /> the location(s) of the system component(s), and specify the performance requirements per Section <br /> M1505.4.1. The system should be located in a central area that is open to and has unobstructed air flow <br /> with the majority of the habitable space. Alternatively, if the system is not centrally located, the system <br /> should provide ducting to each room of the house per Section MlS05.4.1.1. and the drawings should <br /> specify a requirement for testing to verify air flow rates per Section M1505.4.1.6. The system should not <br /> have a sound rating exceeding 1.0 sones. <br /> 16. The bathrooms and kitchen should specify exhaust fans including the minimum required performance <br /> rates per IRC Table M1505.4.4(1). <br /> 17. The house is required to have a heating system per IRC Section R303.9. The type and location of the <br /> system should be specified. If the system is new, it should be indicated as such in the drawings. Gas <br /> appliances are prohibited in the locations specified in Section G2406. <br /> 18. The house is required to have a water heating system per IRC Section R306.4. The type and location of the <br /> system should be specified. If the system is new, it should be indicated as such in the drawings. Seismic <br /> restraints should be provided per Section M1307.2. Gas appliances are prohibited in the locations specified <br /> in Section G2406. <br /> 19. Details for grab bars should be included for the water closets and shower. The grab bars should be <br /> fastened to blocking installed in the walls capable of resisting a minimum 250-LB load. See IRC Section <br /> R330.8. <br /> 20. Details for the construction of the new ramp should be included. See IRC Section R311.8 and R330.9. <br /> Structural: <br /> 21. The proposed project appears to include structural work. Structural drawing should be submitted that <br /> include framing plans, sections, details, construction schedules, fastening schedules, materials <br /> requirements, general notes, special inspection requirements, etc. The drawings should substantiate <br /> compliance with the prescriptive requirements of the IRC. See IRC Sections R106.1.1 and R301.1. <br /> 22. The modified load paths should comply with the prescriptive limitations of the IRC. Alternatively, an <br /> engineered analysis and design may be performed per IRC Section R301.1.3; sealed and signed drawings <br /> and calculations prepared by a professional engineer licensed in the state of Washington are required per <br /> RCW 18.43.010, 18.43.020, and 18.43.070. See IRC Section R301.1. <br /> 23. Foundations should comply with IRC Chapter 4. Wood-framed construction on foundations should comply <br /> with Section R317.1, including clearance per Item 5. <br /> 24. Headers should comply with IRC Section R602.7. King and jamb studs should be specified for each header <br /> per Section R602.7.5. <br /> 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.