Wise Residence <br /> �A Degenkolb Response to Plan Review Comments <br /> April 1, 2021 <br /> Page 2 of 4 <br /> Architectural <br /> The attic area has been converted to habitable space. Sections should be provided <br /> through this area showing that it complies with the minimum requirements of <br /> Sections R304 and R305. See additional comments below. <br /> Response:Attic space will remain uninhabitable. New permitted habitable space <br /> has been added to the basement. Basement ceiling height is 6' 8", which is <br /> acceptable per IRC Appendix J Section AJ501.7. We request that this section be <br /> accepted in lieu of the 7 ft requirement in WSRC Section R305. <br /> 2. ections and details should be provided for the stairway leading to the attic area. <br /> — he stairway should comply with minimum width and ceiling clearances. See IRC <br /> Section R311.7. Show handrails complying with Section R311.7.8. Provide artificial <br /> lighting per IRC Section R303.7. <br /> Response:Attic space will remain uninhabitable. New permitted habitable space <br /> has been added to the basement. Basement has compliant egress stairs as <br /> indicated on sheet A2.1. A new compliant handrail will be added at the basement <br /> stairs. <br /> The attic bathroom should have local exhaust per IRC Sections and M1507.4 (WAC). <br /> 7 <br /> Response: See response to General comment#1. Basement bathroom will be <br /> provided with local exhaust. <br /> /The attic space should be insulated to provide a thermal envelop complying with the <br /> 2015 WSEC. The thermal rating (i.e., Rmin, Umax) should be specified for each <br /> component of the building (e.g., walls, windows). Prescriptive values should be <br /> specified per WSEC Tables R402.1.1 or R402.1.3. Note that R-13 insulation as <br /> specified on Sheet A2.3 is not sufficient for this level as it is new habitable space. <br /> Alternatively, the thermal envelop may be designed per the Total UA method of <br /> WSEC Section R402.1.4; calculations substantiating the design should be included <br /> in the submittal documents. <br /> Response: See tables on sheets A2.1-2.4 for prescribed thermal ratings. Attic will <br /> remain uninhabitable. <br /> ( 5 ,i+he roof should specify ventilation per Section R806. Calculations for the minimum <br /> areas should be provided; the area should be evenly distributed between the eaves <br /> and ridges. A minimum 1" air gap should be provided between the insulation and <br /> roof sheathing per Section R806.3. <br /> Response: See attic ventilation calculation on roof framing plan (S2.4). There is not <br /> enough ridge length available to provide 1/300 balanced ventilation so we will supply <br /> the 1/150 area at the eaves. <br /> (The attic spaces should provide access hatches per IRC Section R807. <br />