V ES EVALUATION • - 565 <br /> o Originally Issued: 03/08/2018 Revised: 05/03/2021 Valid Through: 03/31/2022 <br /> HUNTSMAN BUILDING SOLUTIONS (dba 2.4 During application, the insulation shall be protected <br /> DEMILEC (USA), INC.) from exposure to weather. <br /> 3315 East Division Street <br /> Arlington,Texas 76011 2.5 The insulation shall be installed by professional spray <br /> Phone: (817) 640-4900 polyurethane foam installers authorized by Demilec <br /> www.demilec.com (USA),Inc. <br /> HEATLOK®HFO PRO SPRAY-APPLIED 2.6 Use of the insulation in areas of"very heavy"termite <br /> POLYURETHANE FOAM PLASTIC infestation probability shall be in accordance with 2018, <br /> INSULATION 2015 and 2009 IBC Section 2603.8 and 2012 IBC Section <br /> 2603.9 or IRC Section R318.4,as applicable. <br /> CSI Section: <br /> 07 2100 Thermal Insulation 2.7 Heatlok® HFO PRO insulation qualifies as a vapor <br /> retarder when installed as required in Section 4.7 of this <br /> 1.0 RECOGNITION report. <br /> Heatlok®HFO Pro spray-applied polyurethane foam plastic 2.8 Labeling and jobsite certification of the insulations and <br /> insulation has been evaluated for use as spray foam coatings shall comply with the following code sections as <br /> insulation complying with IBC Section 2603, IRC Section applicable: <br /> R316,and 2018,2015,and 2012 IECC Section C303,C402, • 2018,2015 or 2012 IBC Section 2603.2 <br /> R303, and R402. The physical properties, water vapor • 2018,2015 or 2012 IRC Section R316.2 <br /> resistance, air permeance, thermal resistance, surface • 2018 and 2015 IRC Section N1101.10.1.1 <br /> burning characteristics and attic and crawl space • 2012 IRC Section N1101.12.1.1 <br /> installations,and Type V construction and exterior walls of • 2009 IRC Section N1101.4 <br /> Types I-IV construction were evaluated to comply with the • 2018, 2015, 2012 or 2009 IECC Section <br /> intent of the following codes and regulations: C303.1.1.1 or R303.1.1.1 <br /> • 2018,2015, 2012 and 2009 International Building 2.9 The insulation shall be produced by Demilec (USA), <br /> Code®(IBC) Inc.in Arlington,TX. <br /> • 2018, 2015, 2012 and 2009 International <br /> Residential Code®(IRC) 3.0 PRODUCT USE <br /> • 2018, 2015, 2012 and 2009 International Energy <br /> Conservation Code®(IECC) Heatlok®HFO Pro spray-applied polyurethane foam <br /> plastic insulation complies with IBC Section 2603,IRC <br /> 2.0 LIMITATIONS Section R316 and 2018,2015 and 2012 IECC Sections <br /> C303,C402,R303,and R402 and 2009 IECC Sections 303 <br /> Use of Heatlok® HFO Pro spray-applied polyurethane and 402.When installed in accordance with Section 4.0 of <br /> foam plastic insulation recognized in this report is subject this report,the foam plastic insulation is for use in wall <br /> to the following limitations: cavities,floor assemblies or ceiling assemblies, exterior <br /> side of vertical foundations or the underside of on-grade <br /> 2.1 The insulation and coating products shall be installed slabs. It may be used in attics and crawl spaces when <br /> in accordance with the manufacturer's published installed with Section 4.5.1. Heatlok®HFO Pro insulation <br /> installation instructions, this evaluation report and the applicable code. If there are any conflicts between the is used in Types I,II,III,IV and V construction under the manufacturer's published installation instructions and this IBC and in one-and two-family dwellings under the IRC. <br /> report,the more restrictive shall govern. 4.0 PRODUCT DESCRIPTION <br /> 2.2 Except as permitted by the applicable building code, 4.1 Properties: Heatlok® HFO Pro is a medium density, <br /> the insulation shall be separated from the interior of the closed cell, spray-applied polyurethane foam plastic <br /> building by a code-complying thermal barrier or shall be insulation in accordance with Table 1 of AC377. The <br /> installed as an alternative thermal barrier assembly in insulation has a nominal in-place density of 2.0 lb/ft3 (32 <br /> accordance with Section 4.5.1 of this report kg/m3).The two-component spray foam plastic is produced <br /> 2.3 The insulation shall not exceed the nominal density and in the field by combining a polymeric isocyanate (A <br /> thickness for the installation conditions described in this component) and the Heatlok HFO Pro resin (B <br /> report. component). The liquid components shall be stored in 55- <br /> gallon(208 L)drums at temperatures between 50°F and <br /> The product described in this Uniform Evaluation Service(UES)Report has been evaluated as an alternative material,design or method of construction in order to satisfy and comply with <br /> the intent of the provision of the code as noted m this report,and for at least equivalence to that prescribed in the code in quality,strength,effectveness fire resistance durability and safety, <br /> P P q P 9 tY. 9 Y Y. <br /> as applicable,in accordance with IBC Section 104.11.This document shall only be reproduced in its entirety. <br /> Copyright©2021 by Intematonal Association of Plumbing and Mechanical Officials.All rights reserved.Printed in the United States.Ph:1-877-41ESRPT•Fax:909.472.4171 <br /> web:www.uniforrn-es.org•4755 East Philadelphia Street,Ontario,California 91761-2816—USA <br /> Page 1 of 7 ISWEc,7065 <br /> "Uct ce"Mcau-Body <br /> M75 <br />