Laserfiche WebLink
qa <br /> • - 565 <br /> Originally Issued: 03/08/2018 Revised: 05/03/2021 Valid Through: 03/31/2022 <br /> 100°F (10°C and 38°C) for the polymeric isocyanate and The manufacturer's published installation instructions for <br /> 59°F and 77°F(15°C and 25°C)for the Heatlok®HFO Pro Heatlok® HFO Pro insulation and this report shall be <br /> resin.When Component A and Component B are stored in available on the jobsite during installation.Where conflicts <br /> factory-sealed containers at the recommended occur,the most restrictive governs. <br /> temperatures,the maximum shelf life is twelve months for <br /> the polymeric isocyanate and six months for the Heatlok® Heatlok®HFO Pro insulation shall be spray-applied on the <br /> HFO Pro resin. jobsite using equipment specified in the manufacturer's <br /> published installation instructions. The maximum in- <br /> 4.2 Thermal Resistance (R-Values): Heatlok®UFO Pro service temperature for all areas shall not exceed the <br /> spray-applied polyurethane foam plastic insulation has a maximum temperature stated in the manufacturer's <br /> thermal resistance (R-Value) at a mean temperature of published installation instructions. The insulation shall be <br /> 75°F(24°C)as shown in Table 1 of this report. sprayed onto a clean,dry substrate that has been prepared <br /> in accordance with the manufacturer's installation <br /> Table 1 instructions. The insulation shall not be used in electrical <br /> Thermal Resistance(R-Values)' outlets or junction boxes or where the insulation will be in <br /> Thickness Heatlok®HFO Pro direct,continuous contact with water. <br /> (inch) R-Value('IF•ft2-h/Btu <br /> 1 7.4 4.5.1 Thermal Barrier <br /> 1.5 11 <br /> 2 14 4.5.1.1 Application with an Approved Thermal Barrier: <br /> 3 20 Except as provided for in Section 4.5.1.2 of this report, <br /> 3.5 23 Heatlok® HFO Pro spray-applied polyurethane foam <br /> 4 26 plastic insulation shall be separated from the interior by a <br /> 5 33 thermal barrier in accordance with IBC Section 2603.4 or <br /> 5.5 36 IRC Section R316 as applicable. When the insulation is <br /> 6 40 separated from the interior by a prescriptive thermal barrier <br /> 7 46 in accordance with IBC Section 2603.4 or IRC Section <br /> 7.5 49 R316,the insulation thickness shall not be limited. <br /> 8 53 <br /> 9 59 4.5.1.2 Alternative Thermal Barrier Assemblies: <br /> 10 66 Heatlok® HFO Pro spray-applied polyurethane foam <br /> 11 72 plastic insulation may be installed without a thermal barrier <br /> 11.5 76 as defined in Section 4.5.1.1 of this report when installed <br /> 12 79 in accordance with Table 2 of this report and as referenced <br /> For SI: 1 inch=25.4 min,1°F.ft2-hBtu=0.176 110 K-m2/W. in IAPMO UES ER-499 or additional report b an <br /> IR-Values are calculated based on tested K values at 1-inch and 4- p y <br /> inch thicknesses. approved evaluation entity to the requirements of AC456. <br /> 4.3 Surface Burning Characteristics: At a maximum 4.5.2 Installation in Attics or Crawl Spaces: Heatlok® <br /> thickness of 4 inches (102 mm) and a nominal density of HFO Pro spray-applied polyurethane foam plastic <br /> 2.0 lb/ft3(32 kg/m3),the Heatlok®HFO Pro insulation has insulation may be installed in attics or crawl spaces when <br /> a flame spread index of 25 or less and smoke-developed installed in accordance with this section(Section 4.5). <br /> index of 450 or less when tested in accordance with ASTM <br /> E84. Greater thicknesses, depending on the end use, are When installed in attics or crawl spaces where entry is <br /> recognized when installed in accordance with this report. made only for the service of utilities, Heatlok® HFO Pro <br /> insulation may be installed in accordance with this section. <br /> 4.4 Fire-Protective Coatings and Coverings: Fire Heatlok® HFO Pro insulation need not be surfaced with a <br /> protective coatings, for use as alternative thermal barrier thermal barrier,however, such attic and crawl space areas <br /> assemblies, shall be in accordance with Table 2 of this shall be separated from the interior of the building by a <br /> report, as applicable, and installed in accordance with thermal barrier in accordance with Section 4.5.2 of this <br /> Section 4.5 of this report. report. <br /> 4.5 Installations: Heatlok® HFO Pro spray-applied 4.5.2.1 Installation Using a Prescriptive Ignition <br /> polyurethane foam plastic insulation shall comply with one Barrier: When installed within attics or crawl spaces <br /> of the following requirements: where entry is made only for the service of utilities, <br /> Heatlok® HFO Pro spray-applied polyurethane foam <br /> • 2018, 2015, 2012 and 2009 IECC Sections plastic insulation at a maximum thickness of 7.5 inches <br /> C402.1 (prescriptive) (191 mm) on walls and other vertical surfaces and 11.5 <br /> • 2018, 2015, 2012 and 2009 IECC Section R407 inches (292 mm) on ceilings and other overhead surfaces <br /> (performance) shall be covered with a prescriptive ignition barrier in <br /> Page 2 of 7 <br />