My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
620 LAUREL DR 2025-04-16
>
Address Records
>
LAUREL DR
>
620
>
620 LAUREL DR 2025-04-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/16/2025 9:43:08 AM
Creation date
3/20/2025 11:51:30 AM
Metadata
Fields
Template:
Address Document
Street Name
LAUREL DR
Street Number
620
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
qq E g • - 565 <br /> o Originally Issued: 03/08/2018 Revised: 05/03/2021 Valid Through: 03/31/2022 <br /> accordance with IBC Section 2603.4.1.6 or IRC Sections 4.6 Air Permeability: When tested in accordance with <br /> R316.5.3 and R316.5.4,as applicable. ASTM E2178 at a minimum thickness of 1 inch(25.4 mm), <br /> Heatlok® HFO Pro spray foam insulation is classified as <br /> Exception: The prescriptive ignition barrier may air-impermeable insulation in accordance with Section <br /> be omitted when installed in accordance with 1202.3 of the 2018 IBC, Section 1203.3 of the 2015 IBC, <br /> Section 4.5.2.2 of this report. and Section R806.5 of the 2018, 2015 and 2012 IRC or <br /> Section R806.4 of the 2009 IRC,as applicable. <br /> 4.5.2.2 Installation Using an Alternative Ignition <br /> Barrier Assembly: Heatlok® UFO Pro spray-applied 4.7 Vapor Permeance: Heatlok® HFO Pro spray-applied <br /> polyurethane foam plastic insulation may be installed in polyurethane foam plastic insulation, when tested in <br /> attics and crawl spaces using an alternative ignition barrier accordance with the ASTM E96 desiccant method <br /> assembly provided: (Procedure A), has a permeance of less than 1.0 perms <br /> a. Entry is only to service utilities in the attic or (57.4 x 101 g/Pa•s•m),at a minimum thickness of 1 inch(25 <br /> crawl space and no storage is permitted. mm) and qualifies as a Class 11 vapor retarder in <br /> b. Attic or crawl space areas cannot be accordance with IBC Section 202 and IRC Section R202. <br /> interconnected. 4.8 One-hour fire-resistance rated assembly: The <br /> c. Air from the attic or crawl space cannot be following load-bearing assembly based on testing to <br /> circulated to other parts of the building. ASTM El 19 provides a one-hour fire-resistance rating. <br /> d. Attic ventilation is provided as required by 2018 <br /> IBC Section 1202.2, 2015 and 2012 IBC Section Framing: 35/8-inch (92 mm) 20-gauge steel studs with a <br /> 1203.2 or IRC Section R806 except where air- maximum height of 10 feet(3 m)spaced at 16 inches(406 <br /> impermeable insulation is permitted in unvented mm)on center inserted in a 20-gauge top and bottom steel <br /> attics and shall comply with the following code <br /> sections as applicable: track with lateral bracing at mid-wall height. <br /> For Unvented Attics: Exterior Surface: Two layers Of'/8-inch-thick (15.9 mm) <br /> glass mat gypsum substrate complying with ASTM C 1177. <br /> • 2018 IBC Section 1202.3 The base layer is installed with the long edge parallel to the <br /> • 2015 IBC Section 1203.3 studs with #6 by 11/2-inch-long (38 mm) drywall screws <br /> • 2018,2015,2012 and 2009 IRC Section spaced at 8 inches(203 mm)on center around the perimeter <br /> R806.5 and 12 inches (305 mm) on center in the field. The face <br /> layer is installed with the long edge parallel to the studs <br /> Crawl space ventilation is provided as required by with the base layer and face layer joints staggered by one <br /> the following code sections as applicable: stud space. The face wall is secured with#6 by 1 /8-inch- <br /> long(48 mm)drywall screws spaced at 8 inches(203 mm) <br /> • 2018 IBC Section 1202.4 on center around the perimeter and 12 inches(305 mm)on <br /> • 2015 IBC Section 1203.4 center in the field. <br /> • 2012 and 2009 IBC Section 1203.3 <br /> • 2018,2015,2012 and 2009 IRC Section Insulation: 35/8-inch-thick(92 mm)layer of Heatlok®HFO <br /> R408.1 Pro spray-applied polyurethane foam plastic insulation <br /> applied in the cavities to the exterior gypsum completely <br /> e. The foam plastic insulation is limited to the filling the stud cavities. <br /> maximum thickness and density tested as shown Interior Cladding: Two layers of 5/8-inch-thick(15.9 mm) <br /> in Section 4.5.2.2.1 of this report. Type X gypsum board complying with ASTM C 1396. The <br /> f. In accordance with IMC (International <br /> Mechanical Code®) Section 701, combustion air base layer shall be installed with the long edge parallel to <br /> is provided. the studs with#6 by 1 /2-inch-long(38 mm)drywall screws <br /> spaced at 8 inches(203 mm)on center around the perimeter <br /> 4.5.2.2.1 Alternative Ignition Barrier Assembly: and 12 inches (305 mm) on center in the field. The face <br /> Heatlok® HFO Pro spray-applied polyurethane foam layer shall be installed with the long edge parallel to the <br /> plastic insulation may be installed without a prescriptive studs with the base layer and face layer joints staggered by <br /> ignition barrier on walls, floors, ceilings and other vertical one stud space. The face wall is secured with#6 by 1 /B- <br /> and horizontal surfaces as defined in Section 4.5.2.1 of this inch-long(48 mm)drywall screws spaced at 8 inches(203 <br /> report when limited to a maximum thickness of 7.5 inches mm) on center around the perimeter and 12 inches (305 <br /> (191 mm) on walls and other vertical surfaces and 11.5 mm)on center in the field. <br /> inches(292 mm)on ceilings and other overhead surfaces. 4.9 Exterior Walls of Buildings of Type I,II,III or IV <br /> Construction: When Heatlok® HFO Pro spray-applied <br /> polyurethane foam plastic insulation is used in exterior <br /> Page 3 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.