VUESNumber: <br /> o Originally Issued: 03/08/2018 Revised: 05/03/2021 Valid Through: 03/31/2022 <br /> walls of buildings of Type I, II, III or IV construction of 6.5 Fire-resistance testing to ASTM E119. <br /> any height, the insulation shall comply with IBC Section <br /> 2603.5 and this section. Heatlok HFO Pro insulation shall 6.6 Report of fire-propagation characteristics tests in <br /> be installed at a maximum thickness of 35/8 inches (92 accordance with NFPA 285. <br /> mm). <br /> 6.7 Third party engineering analysis for extension of NFPA <br /> 4.9.1 Complying Exterior Wall Assemblies: Wall 285 results. <br /> assemblies that comply with Section 2603.5 of the IBC and <br /> this report that may be used in exterior walls of buildings 6.8 Test reports are from laboratories in compliance with <br /> of Type 1, 11, 111 or IV construction of any height are ISO/IEC 17025. <br /> described in Tables 3 and 4 of this report. <br /> 5.0 IDENTIFICATION 7.0 STATEMENT OF RECOGNITION <br /> The spray foam insulation is identified with the following: This evaluation report describes the results of research <br /> completed by IAPMO Uniform Evaluation Service on <br /> a. Manufacturer's name(Demilec(USA),Inc. or Heatlok®HFO Pro to assess conformance to the codes and <br /> Demilec(Canada,Inc.) standards shown in Section 1.0 of this report and documents <br /> b. Manufacturer's address and telephone number, the product's certification. The product is manufactured at <br /> c. the product trade name(Heatlok®UFO Pro) location noted in Section 2.9 of this report under a quality <br /> d. use instructions control program with periodic inspections under the <br /> e. density,flame-spread and smoke-development supervision of IAPMO UES <br /> indices <br /> f. date of manufacture or batch/run number <br /> g. thermal resistance values For additional information about this evaluation report please visit <br /> h. the evaluation report number(ER-565) www.uniform-es.org or email at info(&uniform-es.org <br /> i. the name or logo of the inspection agency <br /> Either mark of conformity may be used as shown below: <br /> D <br /> IAPMO UES ER-565 <br /> 6.0 SUBSTANTIATING DATA <br /> 6.1 Data in accordance with the ICC-ES Acceptance Criteria <br /> for Spray-applied Foam Plastic Insulation, AC377, dated <br /> April 2016,including Appendix X. <br /> 6.2 Flammability Testing to NFPA 286, Standard Methods <br /> of Fire Tests for Evaluation of Contribution of Wall and <br /> Ceiling Interior Finish to Room Fire Growth. <br /> 6.3 Report of air permeance testing in accordance with <br /> ASTM E2178. <br /> 6.4 Report of water vapor transmission performance in <br /> accordance with ASTM E96. <br /> Page 4 of 7 <br />