Laserfiche WebLink
Lighting, Motor and Electrical Requirements List, pg 3 of 13 <br /> 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1-- Administered by©2024 NEEA,All rights reserved <br /> The following information is necessary to check a permit application for compliance with the lighting systems,motors and electrical system requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> NA Identify sidelit and toplit daylight zones that <br /> are not provided with daylight responsive <br /> controls and the exception(s)that apply <br /> NA C405.2.5.1 Daylight responsive I Indicate on plans that all daylight responsive <br /> controls controls provide continuous dimming to <br /> <15%full light output <br /> I — <br /> NA C405.2.5.1 Daylight responsive Indicate that daylight responsive controls are <br /> controls configured to completely shut off all <br /> controlled lighting fixtures within the lighting <br /> zone. <br /> NA C405.2.6 Additional controls- Identify spaces and lighting fixtures on plans <br /> Specific application that require specific application lighting <br /> lighting controls controls per this section. <br /> NA C405.2.6, Additional lighting Indicate on plans that all display,accent and <br /> Items 1.1 thru controls for display, supplemental task lighting fixtures are <br /> 1.6 accent& controlled independently from general area <br /> supplemental task lighting <br /> lighting <br /> NA C405.2.6, Display and accent For display and accent lighting fixtures, <br /> Items 1.1 and lighting including lighting fixtures added per the <br /> 1.2 C405.2.2.I additional interior lighting power <br /> allowance,indicate on plans the separate <br /> manual controls for these fixtures and the type <br /> of automatic off controls(occupanc <br /> NA For display case lighting fixtures,indicate on <br /> plans the separate manual controls for these <br /> fixtures and the type of automatic off controls <br /> (occupancy sensor or time-switch) <br /> NO C405.2.6, , Supplemental task For supplemental task lighting fixtures <br /> Item 1.4 lighting including under-shelf or under-cabinet <br /> lighting,indicate on plans the separate manual <br /> controls for these fixtures and the type of <br /> automatic off controls(occupancy sensor or <br /> time-switch) <br /> NA C405.2.6, Lighting equipment For lighting equipment for sale or <br /> Item 1.5 for sale or demonstration,indicate on plans the separate <br /> demonstration manual controls for these fixtures and the type <br /> of automatic off controls(occupancy sensor <br /> or time-switch) <br /> NA For exhibit lighting fixtures in galleries, <br /> museums and monuments,indicate on plans <br /> the separate manual controls for these fixtures <br /> and the type of automatic off controls <br /> (occupancy sensor or time-switch). <br /> C405.2.6. Permanently installed indicate method of automatic off control of • <br /> —— <br /> Item 2 lighting in sleeping all installed luminaires in sleeping units <br /> Units (vacancy or captive key card control):also <br /> refer to Receptacles. <br /> I � <br /> Page-314,3 is <br />