My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3214 BROADWAY SEPA 017 - 004 Geotech Report 2025-04-14
>
Address Records
>
BROADWAY
>
3214
>
SEPA 017 - 004
>
Geotech Report
>
3214 BROADWAY SEPA 017 - 004 Geotech Report 2025-04-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/14/2025 7:52:01 AM
Creation date
4/3/2025 9:54:53 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
3214
Tenant Name
SEPA 017 - 004
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
American Property Develow..,ent ES-0599.05 <br /> January 16, 2015 Page 12 <br /> Updated January 22, 2015 <br /> Retaining walls should be backfilled with free draining material that extends along the height of <br /> the wall, and a distance of at least 18 inches behind the wall. The upper one foot of the wall <br /> backfill can consist of a less permeable (surface seal) soil, if desired. In lieu of free draining <br /> backfill, use of an approved sheet drain material can also be considered, based on the <br /> observed subsurface and groundwater conditions. The geotechnical engineer should review <br /> conditions at the time of construction and provide recommendations for sheet drain, as <br /> appropriate. A perforated drain pipe should be placed along the base of the wall, and <br /> connected to an appropriate discharge location. Where foundation walls are formed against the <br /> temporary shoring walls, the shoring wall drainage illustrated on Plate 6 can be utilized. For <br /> site retaining walls receiving backfill, the retaining wall and drainage detail illustrated on Plate 7 <br /> should be considered. <br /> Excavations and Slopes <br /> The Federal and state Occupation Safety and Health Administration (OSHA/WISHA) classifies <br /> soils in terms of minimum safe slope inclinations, In our opinion, based on the soil conditions <br /> encountered during fieldwork for this site, the weathered native soils and existing fill <br /> encountered to depths of up to four feet to seven feet would be classified by OSHA/WISHA as <br /> Type B. Temporary slopes in Type B soils should be sloped at an inclination of at least 1 H:1 V, <br /> or flatter. In our opinion, the dense to very dense native soils below the weathered native soil <br /> and fill would be classified by OSHA/WISHA as Type A and B. Temporary slopes over four feet <br /> in height in Type A and Type B soils should be sloped at an inclination no greater than <br /> 0.75H:1V or 1 H:1V, respectively. With respect to the proposed building excavations, temporary <br /> slopes inclined at 0.5H:1V are feasible within the very dense silty sand with gravel glacial till <br /> deposits. The geotechnical engineer should observe the excavations to verify the appropriate <br /> allowable temporary slope inclination. <br /> If the above slope gradients cannot be achieved, temporary shoring may be required. <br /> Permanent slopes should maintain a gradient of 2H:1V, or flatter, and should be planted with an <br /> appropriate species of vegetation to enhance stability and to minimize erosion. <br /> Seismic Considerations <br /> The 2012 International Building Code specifies several soil profiles that are used as a basis for <br /> seismic design of structures. The 2012 IBC recognizes ASCE for seismic site class definitions. <br /> If the project will be permitted under the 2012 IBC, in accordance with Table 20.3-1 of ASCE, <br /> Minimum Design Loads for Buildings and Other Structures, Site Class C, should be used for <br /> design. In our opinion, the site has a low susceptibility to liquefaction. The absence of a <br /> shallow groundwater table observed at the test sites, and the soil relative density observed <br /> throughout the test sites is the primary basis for this conclusion. <br /> Earth Solutions NW, LLC <br />
The URL can be used to link to this page
Your browser does not support the video tag.