Laserfiche WebLink
a GENERAL UNIT PLAN NOTES <br /> 46-0" '11` <br /> 2 /4- T-13/4" 2'-8' T-10" T-0" 5'-0" 9'-10" T-3" 2'-9- 4 1. LEVELS 2.6:TYPE V-A. VI/ <br /> 60" - ALL LEVELS FULLY SPRINKLERED PER NFPA 13. <br /> 7C VERIFY 2. SEE SHEETS A040-A041 FOR FIRE-RESISTIVE ASSEMBLY TYPES OHNSON BRAUNDIxc. <br /> w 26" ------ °' _ LEVELS TYPICAL2 TO 6--T1ALL YES 15200 PE V-A CONSTRUCTION Suite 300nd Ave.South <br /> 1 Seallle,WA 98188 <br /> a WALL MOUNTED, <br /> FOLDING ROLL. 7C CORRIDOR WALL Phone 206.766.8300 <br /> 21" SHOWER SEAT. 1 A130 18-i/ 1-8" ", REF. O O <br /> CONTROLS 1 7A EXTERIOR WALL vmvjonnsonbrauntl.wm <br /> 24" 3' 7C �- -- ARCHITECTURE <br /> 36" I I M.BATH � v <br /> " 1o: 18 _ 7D UNIT DEMISING WALLS INTERIOR DESIGN <br /> a W Greg L.Al.. <br /> 0 <br /> Q 1p > 7g INTERIOR WALL(NON-LOAD BEARING) <br /> 4 m I' L A 130 11---- A130- 9--- 7g1 INTERIOR W AD BEARING) Jeffrey A.Williams, <br /> - - �-1 O III J I I ALL(Lit <br /> A550 r 1,' <br /> \ 1j _ <br /> 12 LAUNDRY I' Ili KITCHEN w 3. REFER TO OWNER PROVIDED FINISH&FIXTURE SCHEDULES. <br /> BATH 1 1 I I I I^ III I K I <br /> 18 -RIS 17 -RIS 16 -RIS 15 - PE A RI _ _ �i a p ¢ 4 l <br /> 3� Y in I U 4. X DOOR TYPE-SEE DOOR SCHEDULE ON SHEET A100 <br /> 1/4"=1'-0", UN,IT�.3 1/4"=1'-0' UNIT�.3 1/4"=1'-0'• UNIT 3.3 /4"=1'-" UNIT 3.3 �1 A1301/z_ II z Ih KITCHEN WORK <br /> > j > III, SURFACE PER ICC -- -- Pi ` <br /> - 14 --1 - A117.1 AND CITE l i M.CLOSET q 5. O WINDOW TYPE--SEE UNIT WINDOW SCHEDULE ON SHEET A100 <br /> LL• w w CARP VINri THE CODE I II II <br /> 'a a SECTION 1003.12.3 lq 6. ALL UNITS ON AN ACCESSIBLE STORY SHALL COMPLY WITH WASHINGTON STATE <br /> Cy g• ° 5•-1" I `----- s ` ICC/ANSI 117.1 TYPE B".SEE FLOOR PLANS FOR LOCATIONS. <br /> Ir W �� -41/2" 6'-3" p DW i�1 ( )•, <br /> > III FIVE PERCENT OF TOTAL NUMBER OF UNITS ARE DESIGNATED AS"TYPE A"UNITS <br /> bg VERIFY -- -r, -- _____ <br /> 2'-3 1/2 - ---J SEE SHEET A020 FOR TYPE A CALCULATION.SEE FLOOR PLANS FOR LOCATIONS <br /> 2" b S+lr- S+P SEE UNIT SHEETS FOR"TYPE A.AND"TYPE B"UNIT PLANS. s REGISTERED <br /> SEE ACCESSIBILITY NOTES SHEET A550 ARCHITECT <br /> SEE SHEET A550 FOR ACCESSIBLE DETAILS <br /> �� " b3 A13� 1 II 4 4 S+PI U Iql • 6'-8" 7. REFER TO SEPARATE ELECTRICAL&MECHANICAL DRAWINGS Ixxxx v>arxors-wn.l.�nm <br /> ZS�111� b1 b2 :N I - - - ALIGN sTnTE ar wnsxlxcTox <br /> S+PI (DEFFERED SUBMITTALS) <br /> _____ <br /> b7 KS 1 1 7" 7D O• HARDWIRED SMOKE/CO DETECTOR W/BATTERY BACK-UP -P <br /> 8 ' LIVING j - O EXHAUST FAN � DRYER VENT <br /> i <br /> M __ <br /> I a'-11" I __ <br /> TP HOLDER 18" 28 F1W' 36" Q • I j <br /> BLOCKING MIN. 4" 10,-1" 13'-10" 11'-10" 4" ® WHOLE HOUSE FAN PER IMC REQUIREMENTS k <br /> [o ih <br /> q m <br /> 1 i m MASTER POWER VENT WILL BE REQUIRED FOR DRYER <br /> , EXHAUST LENGTHS THAT EXCEED MANUFACTURER'S <br /> SPECIFICATIONS.SEE MECHANICAL. o' <br /> 1a TYPE'A'BATHROOM 13 iz TYPE'A'BATHROOM BEDROOM <br /> UNIT 3.2 Zj 1/4"-T-0° UNIT 3.2 1/4"=1'-0.. UNIT 3.2 BEDROOM 1 i 1 2'-2" 2'-4" 8.�____ INDICATES LOCATION OF EXHAUST DUCTING i6 a <br /> Ki 7A I FOR DUCTS WITHIN JOIST SPACE-SEE DETAIL A051 R <br /> FILLER 36" 30" 36" L. 36" 24" FILLER 34" 18" 33" 12" FILLER j B f VENT THROUGH ROOF @ 6TH FLOOR y o <br /> 2 _ 9. INDICATES LOCATION OF DROPPED SOFFIT 2&6 <br /> SOFFIT K2 SOFFIT O i " q_5" r D @ T-0"MIN.SEE DETAIL A550 <br /> _ ILI I 7A F 10. ALL EXHAUST VENT TERMINATIONS MUST BE 3 FEET CLEAR FROM ANY <br /> I CL I OPERABLE OPENING INTO THE BUILDING,AND 10 FEET CLEAR FROM <br /> I,' `✓ D I DECK ' ANY MECHANICAL AIR INTAKE.GANG TERMINATIONS TOGETHER UNDER <br /> K3 7A 6'-71/2" ONE SHROUD,AS POSSIBLE. <br /> K3 KS I 0 c <br /> M T-71/2" 4'-6" W .� <br /> RANG _ KS K6 o <br /> OR <br /> REF P.T. 13. REQUIRED CLEAR FLOOR SPACES AS SHOWN ON PLANS:REFER <br /> I` W - 9'-11112" 23'-5" q 01 12'-71/z" <br /> R5 ALSO TO ACCESSIBILITY NOTES SHEETS A550. <br /> FILLER 18" 293/4" 361/4" 36" 24" FILLER 18 33" FILLER 46-0 2 <br /> A501 WOOD 30 X48"CLR.FLOOR SPACE AT FIXTURES&APPLIANCES <br /> 2 ACCESSIBLE (CENTERED)&ONE AREA FREE OF DOOR SWING IN BATH <br /> CONTROLS a <br /> A550 F-----1 1 48"X48"CLR.FLOOR SPACE AT ENTRY DOOR PUSH SIDE-ALL <br /> I UNITS m <br /> 11 TYPE'A'KITCHEN 10 TYPE'A'KITCHEN 2 I 54"X60"CLR.FLOOR SPACE AT PULL SIDE OF ALL PASSAGE $ <br /> DOORS-TYPE A UNIT ONLY <br /> -0" 1/4"=V-0" <br /> 60"MANEUVERING CIRCLE-TYPE A UNITS ONLY <br /> G <br /> 46'-0" 14. CONTROLS,FAN WALL SWITCH&OUTLETS TO BE WITHIN REAC 1a rc <br /> 2" 2 /4" T-1314" 2'-8" T-10" 3'-0" S-0" 9'-10" T-3" 2' 9"' 4' RANGES-SEE ACCESSIBILITY NOTES SHEET A550&DETAIL A550 0 <br /> IRROR VERIFY 11 12 <br /> 15. FOR TUBS AT FIRE-RATED WALL AND FLOOR ASSEMBLIES-SEE ZO <br /> A051;o <br /> A051 <br /> \�Y 1 Sa 0 16. ELECTRICAL PANEL <br /> b9 l 1 n REF. ra <br /> 17. S+P=SHELF&POLE.CLOSET SHELF&POLE IN TYPE A UNITS TO BE (n1. <br /> M.BATH 0 ° ADJUSTABLE TO BE WITHIN REACH RANGE 48"MAX.AFF. +• <br /> - s" I 8 <br /> 11U 11�1 I 3 <br /> 4 �I A130 o-9 - >i �. awl <br /> _FILLER 1z'• 3 1s" �f'�/ �-- N i o III ' UNIT INTERIOR ELEVATION NOTES <br /> -5-, LAUNDRY 7 <br /> � _ III w III 1. DIMENSIONS ARE TO FACE OF G.W.B(NET),UNLESS NOTED OTHERWISE. o <br /> / 9� B OM\TYPE'B' ATHRO / 8 \T BATHROOM KITCHEN BATHRO OPTIO B III KITCHEN Ili 7D 2. FIELDVERIFYALL FINISHED DIMENSION PRIORTO ORDERING CABINETS <br /> 1/4" 1'-0" 1/4" 1'-0" T LL <br /> 6 IA1301 3 III G 40 III AND COUNTERTOPS. 3 N <br /> = = I z_ +Ili O III 3. PROVIDE BLOCKING AT TOILET PAPER HOLDERS,TOWEL BARS,DOOR d rn <br /> STRIKES,DRAPERIES,REMOVABLE CABINET SUPPORTS&GRAB BARS. 5&9 La o <br /> CL M.CLOSET j 4. TYPICAL CABINET SYSTEM PROFILE,SEE DETAIL A550 e <br /> 2' 2" �' LL a a CARP VINri Ili - <br /> b8 DW h KITCHEN KEYNOTES BATH KEYNOTES L cow a o�g 3 <br /> MIRROR > III /C� m O J k <br /> VERIFY • z 2'-31/2' - ----JI V N rn� 3w <br /> d b5 S+p O > S+p Ki EXHAUST,SEE UNIT PLANS FORCONCEAL DU T AT RANGE H bi COUNTEIRL TYPE A&6 ELAV.SINK AND A550 L o <br /> I, ��� 24" ------ EXTENT OF DROPPED SOFFIT. UNITS-SEE <br /> 16I yb3 l b3 9 7D �I i r11 ' S'-8" O OPEN KNEE SPACE FOR 3 a wUa oG <br /> ZI • �y II --_---- a I O CABINETS WI ADJUSTABLE SHELVES b2 VANITY SINK AT ALL i6 1G, w z =' <br /> b4 II S+p O I PER FINISH SCHEDULE. ACCESSIBLE BATHROOMS IN A550 LL N O u- -5 <br /> I O 4 i •ALIGN TYPE A UNITS.EXTEND <br /> m 7 1 S+P I K3 COUNTERTOP 8 BACKSPLASH PER FLOORING UNDER-SEE <br /> U ----- I OWNER SPECIFICATIONS. bg PROVIDE GRAB BARS <br /> j I ADAPTABLE FEATURE FOR A550 <br /> Q18" 24" 12- 4' 11" LIVING j ACCESSIBLE WATERCLOSET <br /> 41 TP HOLDER I <br /> MIN. • • I @ TYPE B UNITS,AND 5 <br /> 0 BLOCKING 1 46 3/4"(33"MIN) 10'-1" 9'-7" I 13,-10" I 11'-10" 4" O ADA COMPLIANT FAUCET W/LEVER INSTALL GRAB BAR @ TYPE A550 <br /> U I I K5 HANDLE(ALL UNITS) A UNITS-SEE <br /> 3 7 6 5 I I MASTER O PROVIDE GRAB BARS 5 <br /> li - i i K6 REMOVABLE CABINET(ADAPTABLE ADAPTABLE FEATURE FOR A550 <br /> 1/4"=V-0", OpTlO B 1/4"=V-0", OPTION B 1/4"=1'-0'• OPTION B�1 I I FEATURE)@ OPEN KNEE SPACE FOR SHOWER OR TUB @TYPE B <br /> 1 SINK AND LOWERED WORKSPACE @ UNITS AND INSTALL GRAB �g <br /> K7 BEDROOM 2 I 34"MAX.AFF TO SINK RIM/27"MIN <br /> 7q 2, 2• �L 2 a" BAR@TYPEAUNITS-SEE <br /> FILLER 36" 30" 36" 36" 24" FILLER 2" 34" 18" 33" 12" FILLER BEDROOM 1 1 I 7D KNEESPACE-EXTEND FLOORING A550 <br /> 0 j UNDER O MIRROR-4GEOF.MAX TO <br /> B TYPE A ACCESSIBLE UNITS ONLY b5 BOTTOM EDGE OF <br /> E SOFFIT K2 SOFFIT i i ( ) <br /> E I I I I i REFLECTING SURFACE. <br /> 4'-5' i O K7 BLIND CORNER CABINET O SURFACE MOUNTED LIGHT PROJECT#: 1827 <br /> �� 7A I MICROWAVE&HOOD PER OWNER BAR <br /> K3 KS DRAWN BY: AT <br /> _ �L I O SPECIFICATION TUB&SURROUND PER <br /> G K3 KS O DECK `� `� b7 OWNER SPECIFICATION. <br /> 7A 6'-7 1/2 RANGE W/FRONT CONTROLS CHECKED BY: ST <br /> `y o ,0 11 _ - 0- K9 (TYPEAACCESSIBLE UNITS ONLY) b8 WIRE SHELVING <br /> - T-71/2^ a'-s^ 3 BEDROOM PLANS& <br /> RANGE K6 REF 7A RANGE HOOD ONLY.PROVIDE WALL b9 PLASTIC <br /> CL SWITCH AT46"MAX.AFF.PROVIDE LAMINATECOUNTERTOP& ELEVATIONS <br /> COUNTERTOP MICROWAVE(TYPE A BACKSPLASH PER OWNER <br /> P.T. ACCESSIBLE UNITS ONLY) SPECIFICATION. <br /> FILLER 18' 293/4' 361/4' 36" 24" FILLER 187/i6'349/18" �J-FILLER 1'-111/2" 23'-6" A01 iT-71/2" <br /> 10 VANITY CABINETS OWNER Al 3 0 <br /> 46'-0" "ADA COMPLIANT"REFRIGERATOR <br /> w 7 2 11 SPECIFICATION. <br /> A550 1 U01 WOOD MAX.54"HT.AFF TO FREEZER <br /> w a ��TYPE'6'KITCHEN 1 3 BEDROOM UNIT-TYPE B(OPTION B BATHI PERMIT SET 10/09/2020 <br /> 1 1'..=1.4. 1/4"=V-0" 1/4"=V-0" UNIT 3.1 <br />