Search
8102 EVERGREEN WAY 2020 EVERETT 4 CORNERS - BLDG A Plans 2025-06-20
>
Address Records
>
EVERGREEN WAY
>
8102
>
EVERETT 4 CORNERS - BLDG A
>
Plans
>
8102 EVERGREEN WAY 2020 EVERETT 4 CORNERS - BLDG A Plans 2025-06-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2025 7:33:04 AM
Creation date
5/9/2025 10:56:40 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8102
Tenant Name
EVERETT 4 CORNERS - BLDG A
Permit
B2010-048
Year
2020
Notes
FOUR CORNERS APTS - BLDG A-5, OVER 1 MULTIFAMILY RESID BLDG
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL UNIT PLAN NOTES <br /> a 13'-9" 6'-9" 7'-5" 2'-7- 5' 0" 2' 6" 11'-6" <br /> 60" 5'-0 1/2" 1. LEVELS 2.6:TYPE V-A. <br /> 7C VERIFY 7C 1 7C ALL LEVELS FULLY SPRINKLERED PER NFPA 13. <br /> 0 <br /> 2. SEE SHEETS A04o-A041 FOR FIRE-RESISTIVE ASSEMBLY TYPES JOHNSON BRAUNDI <br /> N 26" TYPICAL WALL TYPES: 15200 52nd Ave.South <br /> WALL MOUNTED, _ ______ _ 1�_ LEVELS 2 TO 6-TYPE V-A CONSTRUCTION Suite 300 <br /> a FOLDING ROLL-IN 11O I m o iv Seattle,WA 98188 <br /> 21" SHOWER SEAT. J 1 w I`� " REF. 7C CORRIDOR WALL Phone 206.766.8300 <br /> 7 > 112 SI 191I2' -phns-bmund- <br /> 24" 3' CONTROLS / 7A EXTERIOR WALL <br /> 36" tl <br /> 110 ARCHITECTURE <br /> , = in 8 o-_�� - '1311,•q*�401 ' A14 4'-6" 7D UNIT DEMISING WALLS I N T E R IaO9R A N <br /> OMASTER o VERIF ' BATH 1 -------J 'O 7B INTERIOR WALL(NON-LOAD BEARING) J ffmy A Williams <br /> I <br /> DESIGN <br /> wine, <br /> - _- - - 140 <br /> A140 9 O 1 7B1 INTERIOR WALL(LOAD BEARING) <br /> 4 KITCHE I 1 <br /> I a <br /> �I s __ KITCHEN WORK 3. REFER TO OWNER PROVIDED FINISH&FIXTURE SCHEDULES. <br /> -LARPE VINYL - `" j > iv SURFACE PER ICC 7D <br /> 16 RIS 17 RI$ 1s RIS 15 PE I _ S+p A117.1 AND CITE <br /> - - - - - THE CODE 1 4. OX DOOR TYPE-SEE DOOR SCHEDULE ON SHEET Al.. <br /> UNIT4.3 1/4-V-0" UNIT4.3 14'o 1'-' UNIT 4.3 - - r <br /> �. �. �. �. ,� 1 =S+p I w CARPET VIN L 1 <br /> '� SECTION 1003.12.3 <br /> I I¢ • `----- 5. O WINDOW TYPE--SEE UNIT WINDOW SCHEDULE ON SHEET Al.. <br /> ¢ <br /> b6 O i U ¢ > <br /> 0 � <br /> - W 1 1 I 3 DW 6. ALL UNITS ON AN ACCESSIBLE STORY SHALL COMPLY WITH WASHINGTON STATE <br /> `� I > > (ICC/ANSI 117.1)"TYPE B".SEE FLOOR PLANS FOR LOCATIONS. <br /> N i s O I FIVE PERCENT OF TOTAL NUMBER OF UNITS ARE DESIGNATED AS"TYPE A"UNITS <br /> 7A II _ , ,I_____, g <br /> ` 2^ .. I I -i----- F- -w I 1 - r SEE SHEET A020 FOR TYPE A CALCULATION.SEE FLOOR PLANS FOR LOCATIONS <br /> ` = ie M.CLOSET 1 a 1 I =______= 8 a 2'-Sa SEE UNIT SHEETS FOR"TYPE A"AND"TYPE B"UNIT PLANS ^8556 <br /> CL i�-51, n II ' I K ____ I S+P K 1 SEE ACCESSIBILITY NOTES SHEET A550 1 \/ REGISTERED <br /> A \ b b6 m ° ` I 1 1 n ¢ II ¢ ARCHITECT <br /> 1'-6" 6' 0" i 6'-1" 5'-8" 4'-6 14'-0" U SEE SHEET A550 FOR ACCESSIBLE DETAILS - <br /> S+P <br /> O1� 1ti0 ` b3 -------- <br /> r <br /> b4 - - _ _ I _ 7 I FFRF.Y ARTH[IR riII.I.IAM <br /> 4 _ 4 q 7. REFER TO SEPARATE ELECTRICAL&MECHANICAL DRAWINGS sTnTe aF wnswucTOH <br /> (DEFFERED SUBMITTALS) <br /> b7 KS II m O <br /> • HARDWIRED SMOKE/CO DETECTOR W/BATTERY BACK-UPEl : sTunv <br /> 18" 281/4" <br /> TP HOLDER MI = • O O LNING EXHAUST FAN DRYER VENT <br /> BLOCKING 7 1 j ® WHOLE HOUSE FAN PER IMC REQUIREMENTS k <br /> 0 A z i <br /> 14 ' ' 13 ' ' 12 ' ' II i i 1iu POWER VENT WILL BE REQUIRED FOR DRYER e t <br /> _ �________� _______ �I________. NE <br /> 1/4"-V-0" v'I I - I EXHAUST LENGTHS THAT EXCEED MANUFACTURER'S <br /> 1/4"=1'-0" UNIT 4.2� - U IT 4.2� 1/4"=V-0" UNIT 4.2 BEDROOM 1 BEDROOM 2 BEDROOM 3 SPECIFICATIONS.SEE MECHANICAL. o' <br /> K1 I I 8. ____ INDICATES LOCATION OF EXHAUST DUCTING 16 <br /> FILLER 30" 18" 36" 36" 24" FILLER 34" 30" 36" 15" FILLER 10'-8" 2' 4" i 9'-10" i 10'-8" FOR DUCTS WITHIN JOIST SPACE-SEE DETAIL A051 a <br /> 14'-8" 4" <br /> I I I I I VENT THROUGH ROOF @ 6TH FLOOR y o$ <br /> SOFFIT SOFFIT A i i 1'-4" 9. INDICATES LOCATION OF DROPPED SOFFIT 2&6 <br /> F F @ T-0'MIN.SEE DETAIL LEA <br /> J + 10. ALL EXHAUST VENT TERMINATIONS MUST BE 3 FEET CLEAR FROM ANY <br /> K3 w i Ip� OPERABLE OPENING INTO THE BUILDING,AND 10 FEET CLEAR FROM <br /> 5'-0" 7A II i OF `� 7A ANY MECHANICAL AIR INTAKE.GANG TERMINATIONS TOGETHER UNDER <br /> K3 KS b8 5'-2" 5'-10' ONE SHROUD,AS POSSIBLE. <br /> I MW c <br /> 11 5'-11" 5'-3" CL i DECK <br /> RANGE _ K6 o KS � 7A CL <br /> y REF WORK, CL CL _ y <br /> AREA 13. REQUIRED CLEAR FLOOR SPACES AS SHOWN ON PLANS:REFER � <br /> FILLER-\\ 30'N 24" \\36' 24" FILLER 3" 38" FILLER ALSO TO ACCESSIBILITY NOTES SHEETS A550. 1. <br /> ACCES ISLE 112 13'-10" P.T. 2'-13/4' 8 <br /> 1 30"X48"CLR.FLOOR SPACE AT FIXTURES&APPLIANCES � <br /> CONTROLS A550 10'-6" 12'-6" 26-6" (CENTERED)&ONE AREA FREE OF DOOR SWING IN BATH <br /> 11 TYPE'A'KITCHEN 10 <br /> = -0" 1/4"=1'-0" 50'-0" WOOD <br /> 1/4" 1' T----11 48"X48"CLR.FLOOR SPACE AT ENTRY DOOR PUSH SIDE-ALL a <br /> I UNITS m <br /> I 54"X60"CLR.FLOOR SPACE AT PULL SIDE OF ALL PASSAGE `a <br /> 24 BEDROOM 1 INIT TYPI1=A <br /> L____ji DOORS-TYPE A UNIT ONLY o <br /> 1/4"=V-0" UNIT 4.2 <br /> 50'-0" 60"MANEUVERING CIRCLE-TYPE A UNITS ONLY <br /> 13'-9" V-9" 10'-0" 5'-0" 2'-6" 1, 12' 0" - 3 <br /> 5'-01/2" 7'-5" 1'-71/2' 14 a <br /> 7C 7C 14. CONTROLS,FAN WALL SWITCH&OUTLETS TO BE WITHIN REAC rc <br /> VERIFY <br /> b6 1 RANGES-SEE ACCESSIBILITY NOTES SHEET A550&DETAIL A550 0 <br /> 2^ y 1Q, 11 12 <br /> - O _ 1� - - -- 15. FOR TUBS AT FIRE-RATED WALL AND FLOOR ASSEMBLIES-SEE A051 A051 <br /> � I REF. <br /> MIRRO = L - =IT I 16. ELECTRICAL PANEL m <br /> b5 8 F}r- �1 1 1 1 13 I 17. S+P=SHELF&POLE.CLOSET SHELF&POLE IN TYPE A UNITS TO BE (n <br /> r- o <br /> b9 " 6 A140 OPTION B I ADJUSTABLE TO BE WITHIN REACH RANGE 48 MAX.AFF. <br /> y n h 4' 6" i O <br /> --/' <br /> MASTER - _ A140 9 A140 4___ O I Q) a w <br /> �1� tip M.BATH ERI O KfTCHE 7D E� <br /> b 0 I < <br /> 7 .1 b7 CARPET NYL z _ __- �€ <br /> a > > s±P m r UNIT INTERIOR ELEVATION NOTES ;d <br /> ----- €; <br /> 1. DIMENSIONS ARE TO FACE OF G.W.B(NET),UNLESS NOTED OTHERWISE. r z <br /> 7A _ S+p i w CARPET VINYL 2. FIELD VERIFY ALL FINISHED DIMENSION PRIOR TO ORDERING CABINETS 3 n LL <br /> "' = i Z AND COUNTERTOPS. <br /> �9�TYPE BATHROOM ��TYPE BATHROOM ----- <br /> O c7 - 3. PROVIDE BLOCKING AT TOILET PAPER HOLDERS,TOWEL BARS,DOOR rn <br /> 1/4"=1'-0" 11.1=1'-01, 4 y i U F STRIKES,DRAPERIES,REMOVABLE CABINET SUPPORTS&GRAB BARS. 5&9 L 3 0 <br /> ¢ Z DW 4. TYPICAL CABINET SYSTEM PROFILE,SEE DETAIL A550 p <br /> aII > I > ry N <br /> 2" z^ oil O l i r O � r � KITCHEN KEYNOTES BATH KEYNOTES i �w r <br /> II M.CLOSET 6 a I =_______ a 2 5 O N Jk <br /> MIRROR _ II U <br /> I 4 i Sap <¢ Ki CONCEAL DUCT AT RANGE HOOD bi ACCESSIBLE LAV.SINK AND N rn< zrc <br /> xNI 5 1'-6" 6'-0" 6'-1" 5'-8" 4'-6" 14'-0' U O EXHAUST,SEE UNIT PLANS FOR O COUNTER-7VPEA&6 1&1 amm <br /> d I S+P A550 L ❑ ¢E w 3 <br /> m � C°I 8^ ______--- I EXTENT OF DROPPED SOFFIT. UNITS-SEE ❑ a Z � oa <br /> ZI g I O OPEN KNEE SPACE FOR ¢ w U o= G <br /> MIN. L/o3�/ b8 I 7 b2 76 w z <br /> b3 = Q 4 4 4 O CABINETS WI ADJUSTABLE SHELVES VANITY SINK AT ALL Q r 3 _ w3 <br /> PER FINISH SCHEDULE. ACCESSIBLE BATHROOMS IN A550 LL 55 O u° m <br /> m m <br /> TYPE A UNITS.EXTEND <br /> m ' 1ti� 11�1 in K3 COUNTERTOP&BACKSPLASH PER FLOORING UNDER-SEE 9 <br /> OWNER SPECIFICATIONS. b3 PROVIDE GRAB BARS <br /> O ADAPTABLE FEATURE FOR A550 <br /> 1 b • 7 II l O _ j�j LIVING m ACCESSIBLE WATERCLOSET <br /> 461/4"(3W MIN 24" 12 l 5 <br /> @ TYPE B UNITS,AND <br /> ❑ BLOCKINGR A ADA COMPLIANT FAUCET W/LEVER INSTALL GRAB BAR @ TYPE A550 <br /> U x K5 HANDLE(ALL UNITS) A UNITS-SEE <br /> 7 ' 6 ' S ' _ BEDROOM 1 BEDROOM 2 1 BEDROOM 3 O PROVIDE GRAB BARS 5 <br /> 0 O 1 O REMOVABLE CABINET ADAPTABLE <br /> r 1/4"=1'-0"' OPTION B 1/4"=V-0" OPTION B 1 1/4"=V-0° OPTION B t� C 1 K6 ( ADAPTABLE FEATURE FOR A550 <br /> 1 1 II 7D SINK AND LOWERED WORKSPACEOR <br /> SHOWER OR TUB @TYPE B <br /> N 1 @ UNITS AND INSTALL GRAB <br /> m 10'-7" 2'-4'I 1 KEES.AFF TO SINK RIMORI MIN <br /> K1 1 KNEESPACE-EXTEND FLOORING BAR @ TYPE A UNITS-SEE g550 <br /> FILLER 30" 30" 24" 36" 24" FILLER FILLER 34" 30" 36" 15" FILLER 1'-4" <br /> � I 1 I UNDER b5 MIRROR-40"A.F.F.MAX TO <br /> y t 1 (TYPE A ACCESSIBLE UNITS ONLY) BOTTOM EDGE OF <br /> E SOFFIT K2 SOFFIT O l i O F O F REFLECTING SURFACE. <br /> BLIND CORNER CABINET <br /> O _ �.( __ - __ NII j \irJ O SURFACE MOUNTED LIGHT <br /> O <br /> O 2"5' MICROWAVE& <br /> 7A <br /> is <br /> HOOD PER OWNER BAR PROJECT#: 1827 <br /> ' - -10" <br /> II 7A I KS SPECIFICATION O DRAWN BY: AT <br /> 4) K3 5' ON b7 TUB&SURROUND PER <br /> b8 5'-0" 5'-11" 5'-3" OWNER SPECIFICATION. <br /> g K3 K5 DECK CL RANGE W/FRONT CONTROLS CHECKED BY: ST <br /> m - 0 11 7A 2'-13/4" K9 (7ypEAACCESSIBLE UN ITS ONLY) b8 WIRE SHELVING <br /> - "o RANGE HOOD ONLY.PROVIDE WALL b9 PLASTIC 4 BEDROOM PLANS& <br /> U Q RANG _ K6 W REF I SWITCH AT46"MAX.AFF.PROVIDE LAMINATECOUNTERTOP& ELEVATIONS <br /> COUNTERTOP MICROWAVE(TYPE A BACKSPLASH PER OWNER <br /> 1'-6" 1V-6" 12'-6" 25'-6" P.T. ACCESSIBLE UNITS ONLY) SPECIFICATION. <br /> FILLER 24" 36" 24" FILLER 01 10 VANITY CABINETS OWNER Al 4 0 <br /> 30" 36" FILLER 50'-01, ADA COMPLIANT"REFRIGERATOR <br /> 11 " SPECIFICATION. <br /> ui A550 1 2 WOOD MAX.54"HT.AFF TO FREEZER <br /> Z 4 �3�TYPE'B'KITCHEN As01 <br /> wi 1/4"=1 01 1/4-1.0" PERMIT SET 10/09/2020 <br /> LL 1/4"=V-0" UNIT 4.1 1 <br />