8102 EVERGREEN WAY 2020 EVERETT 4 CORNERS - BLDG A Plans 2025-06-20
>
Address Records
>
EVERGREEN WAY
>
8102
>
EVERETT 4 CORNERS - BLDG A
>
Plans
>
8102 EVERGREEN WAY 2020 EVERETT 4 CORNERS - BLDG A Plans 2025-06-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2025 7:33:04 AM
Creation date
5/9/2025 10:56:40 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8102
Tenant Name
EVERETT 4 CORNERS - BLDG A
Permit
B2010-048
Year
2020
Notes
FOUR CORNERS APTS - BLDG A-5, OVER 1 MULTIFAMILY RESID BLDG
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PARKING NOTES <br /> 1. SEE SHEET A001 FOR REQUIRED <br /> PARKING CALCULATIONS. OHNSON BRAUNDINc <br /> 2. PARKING STALL SIZE: 15200 52nd Ave.South <br /> a <br /> Suite 300 <br /> Q =8'-0"X 16'-0"MIN. Seattle,WA 98188 <br /> (20 FT.MIN DRIVE AISLE) Phone 206.766.8300 <br /> -phnaonbmu d- <br /> �S =8'-6"X 18'-6" ARCHITECTURE <br /> (24 FT.MIN.DRIVE AISLE), INTERIOR DESIGN <br /> 3. ACCESSIBLE STALLS: Greg L.AlIW <br /> Jeffrey A.Williams,W Illla <br /> ❑ STANDARD:V-0"MIN WIDTH W/s'-0" <br /> HC ACCESS AISLE ALONG ENTIRE <br /> LENGTH OF STALL. <br /> SEE DETAILS 19/A021 FOR SIGNAGE. <br /> 4. COLUMNS ENCROACH 6"INTO <br /> REQUIRED STALL WIDTH MAX. <br /> 5. ©FUTURE DUAL ELECTRICAL VEHI <br /> CHARGING INFRASTRUCTURE. <br /> SEE SITE PLAN A020 FOR <br /> ADDITIONAL INFORMATION <br /> SHEET NOTES 8556 <br /> REGISTEREDECT ARCHIT <br /> 1. PODIUM CONSTRUCTION TYPE IA <br /> 2. ALL LEVELS FULLY SPRINKLERED PER <br /> IBC 903.3.1.1(NFPA 13). f FFRFY ARTROR W 11AAM <br /> STATE OF WASHINGTON <br /> 3 REFER TO SHEETS CS03 FOR FIRE <br /> ASSEMBLY KEY PLAN W/WALL TYPE sTunP <br /> TAGS 8 LOCATIONS.REFER TO <br /> SHEET SERIES A040 FOR ASSEMBLY <br /> DETAILS. k <br /> 4. 0 INDICATES s m <br /> CONCRETE WALL OR COLUMN PER e t <br /> STRUCTURAL. o <br /> 5. EXIT STAIR ENCLOSURES IN TYPE 1A <br /> CONSTRUCTION SHALL BE 3-HOUR <br /> RATED <br /> ALL VERTICAL SHAFTS SHALL BE 2- ur <br /> a a <br /> 6' HOUR RATED PER IBC 713.4. <br /> 4 <br /> A412 7. O DOOR TYPE-SEE SCHEDULE <br /> A.a A.b A.0 A.d A.e A.f SHEET A100 <br /> 8. REFER TO SHEET SERIES A100 FOR c <br /> 27'-2" 24 21'-9" '-3" 25'-6" 25'-6" UNIT PLAN DOOR B WINDOW <br /> SCHEDULE. 15 <br /> KNOX BOX LOCATION, d <br /> FINAL LOCATION TO BE A311 <br /> I 9. REFER TO SHEET SERIES A100 <br /> VERIFIED IN FIELD ----Y---------------- <br /> SIM. 1 FOR ENLARGED UNIT PLANS. w <br /> 4114"i 9'-61/4" 5'-4" I � <br /> 1 SIGNAGE PER ______ 5 3 g <br /> -.- <br /> p• GENERAL NOTE#23 A�412 A412 10. REFER TO ACCESSIBILITY NOTES <br /> TAI #2-- ON SHEET CS00 <br /> .. r_ ___ -------r 1D 1 20'-93/4' ST-2 11 I __ _ ____ 23•_g^ , 1B <br /> r w <br /> GARAGE SCREEN - it J GARAGE SCREEN m <br /> 11. PROVIDE MECHANICALLY <br /> 0 <br /> FASTENED INSULATION AT ALL = <br /> qp I GE SCRE N I CEILINGS BETWEEN CONDITIONED $ <br /> FIRE a n AND UNCONDITIONED SPACE, <br /> REFER TO 005 - ' REQUIRED RHVA UES.EET A040 FOR <br /> A410 1B -_-_-_ -_-_ a. _-_-_ 12. <br /> m _ ___ _ 12. CORRIDOR VENTILATION CONCEPT p <br /> 1g SHOWN,REFER TO DESIGN/BUILD rc <br /> r -_- _ MECHANICAL PLANS. <br /> DOM.PUMP MPOE ---�- A5--- ° <br /> 003 13. BF.E.C. '5LB ABC'RECESSED/FIRE i <br /> EXTINGUISHERRTET w. <br /> A.2 12 SEE DETAIL: <br /> E. <br /> 6 <br /> SIGNAGE PER - - ------- F o <br /> A051 <br /> GENERAL NOTE#3 1 18� 14" F.E. SURFACE MOUNTED'5LB ABC' <br /> 27'-2" w 21'-53/4" '�80 -81/2"w 14'-93/4" 25'-6" w IL 25'-6" FIRE EXTINGUISHER CABINET = _ <br /> A312 2 O O O LOCATE PER IBC TABLE 906.3 <br /> w N rn (1)75 FT.MAX.SEPARATION o <br /> 3E SEE DETAIL 3/A051 FORMOU <br /> -__________________ ___a __ ______________________________ ____ __ _ _______________ _ _________________ _ _________________________________ HEIGHTING/INSTALLATION <br /> LL -- _ _ <br /> 1 -1-- -- --r- ' €_ <br /> 2 r o ' 15. SIGN PER IBC 1013. <br /> A411 ro N 2%SLOPE-+ F.D. --- 2%SLOPE 2%SLOPE F.D. f 2%SLOPE 2%SLOPE--� GARAGE <br /> EXIT <br /> Q 30 <br /> __________________ ___ ___ __________________________ ___ ___ ___ ______________ _ _________________ ____�__�__ ______________________ 16. REFER TO DESIGN/BUILD g <br /> ELECTRICAL PLANS. <br /> o- a a 1 L 3 0 <br /> O O O 17. REFER TO SHEETA051 FOR d p® <br /> rn To w PENETRATION REQUIREMENTS IN L. ry <br /> FIRE RATED CONSTRUCTION. <br /> L �w z <br /> 18. REFERENCE BUILDING ENVELOPE /0� , U J w go k <br /> 1'-7" F.E. F.E. DRAWINGS FOR ALL WATERPROOFING. V w I w zw <br /> dl A. e - - - - - - - - - - - - - A.5 19. AT DOORS INTO ELECTRICAL CONTROL L o ¢U m 3V <br /> ca PANEL ROOMS,SIGNAGE SHALL BE a Z o <br /> Z x AOA PROVIDED ON THE DOOR STATING r 3 0 = w 3 <br /> m1 2T-2" 25'-6" 25'-6 O' 20'-6" 5'-0" 'ELECTRICAL ROOM' 0 LL N O u_o m Fg <br /> L a <br /> � I I 20. AT DOORS INTO FIRE PROTECTION <br /> EQUIPMENT ROOMS CONTAINING <br /> NI SPRINKLER RISERS,FACP,OR OTHER <br /> SUPPRESION CONTROL ELEMENTS, <br /> Q ig I APPROVED SIGNAGE SHALL BE <br /> 0 PROVIDED AND READILY VISIBLE PER <br /> U <br /> 3 IFC 509.1 <br /> 0 <br /> ILL <br /> N o - <br /> A.6 i i I 24'-6" I � I 23'-6" I 23'-6" <br /> � A.6 <br /> L--------------J ��e-- t <br /> 1B GARAGE SCREEN GARAGE SCREEN i ip GARAGE SCREEN GARAGE SCREEN <br /> rn I I L____ir____ I <br /> c <br /> I <br /> 0 PROJECT#: 1827 <br /> KEY PLAN <br /> is 98-8'• ti DRAWN BY: AT <br /> 4) <br /> g A.a A.b A.0 A.tl A a A.f CHECKED BY: ST <br /> j BLDG A-GARAGE <br /> Ci <br /> WEST <br /> w A210A <br /> BUILDING A <br /> a `/V,/\rV\/ PERMIT SET 10/09/2020 <br /> Z �BLDG A-GARAGE WESTA-GARAGE WEST w <br /> 1 118"=V-0" <br />