My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
200 W MARINE VIEW DR ON TRAC LOGISTICS 2025-09-16
>
Address Records
>
W MARINE VIEW DR
>
200
>
ON TRAC LOGISTICS
>
200 W MARINE VIEW DR ON TRAC LOGISTICS 2025-09-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/16/2025 8:53:18 AM
Creation date
5/30/2025 2:26:43 PM
Metadata
Fields
Template:
Address Document
Street Name
W MARINE VIEW DR
Street Number
200
Tenant Name
ON TRAC LOGISTICS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
454
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
\(t <br /> SHUTLER CONSULTING ENGINEERS, INC. Job Name : Baywood Industrial <br /> Structural Engineers Job No. : 20-33 <br /> 12503 Bel-Red Road, Suite 100 Engr: : CT <br /> Bellevue, washington 98005 Date: : 10-20-2020 <br /> ( (425) 450-4075 Sheet No.: <br /> ***** TILT UP WALL DESIGN ***** <br /> (Considering P-Delta effects per Section 11.8 of ACI 318-14) <br /> Tilt- wall design program, Version 1.0, latest revision 1-8-2018 <br /> Description: Panel 6 - 32" leg Page 1 <br /> ***** ALLOWABLE STRESSES AND DESIGN CRITERIA ***** <br /> f'c of concrete = 5,000.00 psi. <br /> Fy of steel = 60,000.00 psi. <br /> Basic wind speed ---> 110 MPH <br /> Zone of building (zone 4=typ. wall, zone 5=corner.---> 4 <br /> Wind exposure category ( B, C or D ) ---> C <br /> Lamda based on a mean roof height = 35.00 feet <br /> Net design wind pressure based on a calc. trib area = 337.26 sq ft. <br /> Est, Wind topographic factor = 1.00 <br /> Wind load ( p = Lamda * Iw * P net 30 ) = 29.58 psf. <br /> (p = 1.45 * 1.00 * 20.40) <br /> Seismic importance factor = 1.00 <br /> Site class {A, B, C, D, or E) ---> D <br /> Seismic load, Fp = .4 * Sds * Ip * Wp, 0.1 Wp (min) = 38.67 psf. <br /> Fa = 1.00, Ss = 1.25, Sms = 1.25, Sds = 0.84 <br /> Ev = 0.2 * Sds * Ip * D = 0.17 D <br /> Maximum allowed overstress = 0.00 % <br /> Wall thickness for weight calculations = 9.25 inches <br /> Wall thickness for design calculations = 8.50 inches <br /> Parapet height, height of wall above roof. = 3.50 feet <br /> Design height, distance between floor and roof. = 34.00 feet <br /> Fixity coefficient = 0.85 <br /> Tributary width for design loads = 11.67 feet <br /> Uniform dead load on design section = 315.00 # / ft. <br /> Uniform live load on design section = 525.00 * / ft. <br /> Concentrated dead load on design section = 0.00 lbs. <br /> Concentrated live load on design section = 0.00 lbs. <br /> Additional wt. applied to wall. ( ie. Stucco. ) = 0.00 psf. <br /> Eccentricity, dist from center of wall to load = 8.13 inches <br /> Depth to centroid of steel = 7.00 inches <br /> Weight of wall = 115.63 psf. <br /> Weight of wall on design section = 24,220.72 # / ft. <br /> Total design load on design section = 34,023.52 # / ft. <br /> Steel ratio ( As / ( b * d )) = 0.0096 <br /> Modulus of rupture (7.5 * {f'c^.5)) = 530.33 psi. <br /> Modulus of elasticity { Concrete ) = 4,030.51 ksi. <br /> n = Es / Ec = 7.20 <br /> Cracking Moment = 204.35 in.-k <br /> Delta Cracked = 0.39 in. <br /> *************** DESIGN SUMMARY *************** <br /> Ultimate load capacity has been met for all load cases, ( Mu < Phi * Mn ) . <br /> Service load deflection is less than design ht./150 = 2.31 in. for all cases. <br /> Wall is tension controled for all load cases, minimum steel strain is 0.01264 <br /> Maximum axial stress ( 159.11 psi. ) is less than .06 * f'c = 300.00 psi. <br /> Phi Mn is greater than M cracked for all cases. <br />
The URL can be used to link to this page
Your browser does not support the video tag.