Permit #: B2407-048, First Building Review <br /> August 19, 2024 <br /> 17. (IRC M1505.4.2) Please include additional information on whole house fan regarding the system type <br /> (balanced or unbalanced) per Table M1505.4.3(2) and intermittent or continuous per Table <br /> M 1505.4.3.2. <br /> 18. (IRC M1505.4.4.3) Please provide range hood fan for new range. 160 CFM minimum for an electric range <br /> and 260 CFM for a gas range. <br /> 19. (IRC R303.5.2, M1504.3 and M1502.2) Please show location of kitchen, bathroom,washer/dryer and <br /> whole house fan exhaust openings. Please also provide opening protection per IRC R303.6. Please <br /> provide new clothes dryer exhaust per IRC 1502.2. <br /> R303.5.2 Exhaust Openings <br /> Exhaust air shall not be directed onto walkways.All exhaust ducts shall terminate outside the <br /> building.Terminal elements shall have at least the equivalent net free area of the duct work. <br /> M1504.3 Exhaust Openings <br /> Air exhaust openings shall terminate as follows: <br /> 1. Not less than 3 feet (914 mm)from property lines. <br /> 2. Not less than 3 feet (914 mm)from gravity air intake openings, operable windows and <br /> doors. <br /> 3. Not less than 10 feet (3048 mm) from mechanical air intake openings except where either <br /> of the following apply: <br /> 3.1 The exhaust opening is located not less than 3 feet(914 mm) above the air <br /> intake opening. <br /> 3.2 The exhaust opening is part of a factory-built intake/exhaust combination <br /> termination fitting installed in accordance with the manufacturer's instructions, and <br /> the exhaust air is drawn from a living space. <br /> 4. Openings shall comply with Sections R303.5.2 and R303.6. <br /> 20. (WSEC-R R402.1.2, R402.1.3, R402.1.5) Please provide in details of how the building will meet the <br /> thermal requirements for the R21 insulation in the stud cavity and the R-5 continuous insulation on <br /> walls per Table R402.1.3 OR provide U-value calculations per Table R402.1.2 and R402.1.6. Please <br /> update all notes and references throughout the set. <br /> 21. (WSEC-R R402.1.3) Detail 4 on Sheet 4a, R-38 insulation for the roof is only allowed per Table R402.1.3 <br /> Note e "if the full insulation depth extends over the top plate of the exterior wall." R-38 insulation is <br /> about 11.6 inches for blown-in and about 12 inches for batt insulation. Space for attic ventilation would <br /> also need to be provided. Please provide enough space above the top plate per Table R402.1.3 Note (e) <br /> OR provide R-60 in all attic spaces per R402.1.3 OR provide U-value calculations per Table R402.1.2 and <br /> R402.1.6. <br /> 22. (WSEC-R R402.1.3) Detail 5 on Sheet 4a, please provide R-60 in all attic spaces per R402.1.3. <br /> 23. (WSEC-R Table R406.3)The energy code calculations for the additional credit for Efficient Building <br /> Envelope Option 1.2 requires R-38 insulation in the floors.This is shown in the energy worksheet but not <br /> in the details. Please update Detail 1 and 2 on Sheet 4a, and update throughout the set. <br /> Structural (Reviewer: Cal Bearman)) <br /> 24. The calculation package should specify the applicable building codes, including the 2021 <br /> IBC/IRC. Section R106.1.1 and EMC Section 16.005.030. <br /> 3200 Cedar Street © 425.257.8810 O permitservices@everettwa.gov <br /> Everett, WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.