2025 FEDERAL OVERLAY, W MUKILTEO BLVD – GLENWOOD AVE TO DOGWOOD DR <br /> PAGE SP116 OF SP123 SPECIAL PROVISIONS <br />WORK ORDER #3842 April 15, 2025 FEDERAL AID# NHPP-2776(011) <br />15. Circular loops are standard installations. Where shown in the Plans, the 1 <br />contractor shall install quadrupole loops at stop lines due to stub-out 2 <br />diameter. At locations where quadrupole loops are shown and adequate 3 <br />stub-out diameter exists, round loops may be substituted for quadrupole 4 <br />loops. 5 <br /> 6 <br /> 7 <br />Existing Traffic Loops 8 <br /> 9 <br />The Contractor shall notify the Area Traffic Engineer through the Engineer a 10 <br />minimum of five (5) working days in advance of pavement removal or grinding 11 <br />in areas with existing loops. 12 <br /> 13 <br />If the Engineer suspects that damage to any loop, not identified in the Plans as 14 <br />being replaced, may have resulted from Contractor’s operations or is not 15 <br />operating adequately, the Engineer may order the Contractor to perform the field 16 <br />tests specified in Section 8 20.3(14)D. The test results shall be recorded and 17 <br />submitted to the Engineer. Loops that fail any of these tests shall be replaced. 18 <br /> 19 <br />Loops that fail the tests, as described above, and are replaced shall be installed 20 <br />in accordance with current City of Everett design standards and Standard 21 <br />Drawings, as determined by the Engineer. 22 <br /> 23 <br />If traffic signal loops that fail the tests, as described above, are not replaced and 24 <br />operational within 5 working days, the Contractor shall install and maintain 25 <br />interim video detection until the replacement loops are operational. The type of 26 <br />interim video detection furnished shall be approved by the Engineer prior to 27 <br />installation. 28 <br /> 29 <br />GLF 8-20.4.DOCX 30 <br />8-20.4 Measurement 31 <br /> 32 <br />Section 8-20.4 is supplemented with the following: 33 <br /> 34 <br />(******) 35 <br />“Vehicle Loop Detectors”, for both loop perimeter and home run, shall be measured by 36 <br />the linear foot of the neat sawcut line in place in the roadway. No additional measurement 37 <br />will be made for the installation of lead-in conduit and shall be included in the 38 <br />measurement 39 <br /> 40 <br />“Loop Detector Lead-In Cable” shall be measured by the linear foot of the neat line of 41 <br />conduit between the controller cabinet and loop splice. No additional measurement will 42 <br />be made for coiled loop detector cable in junction boxes or cabinets. 43 <br /> 44 <br />“Conduit Pipe 2 In. Diam.” shall be measured by the linear foot of the neat line of conduit 45 <br />between the junction box and the curb line. No additional measurement will be made for 46 <br />sweeps or elbows in junction boxes or at the curb line. 47 <br /> 48