Laserfiche WebLink
The comments below were generated from this project's City of Everett Traffic Engineering Reviewer. All questions shall be routed through this project's <br />Public Works Reviewer Thad Newport with City of Everett Permit Services (TNewport(aDeverettwa.gov). <br /># <br />Document <br />Sht/Pg <br />Reviewer's Comment <br />Designer's Response <br />Initials <br />pole shop drawing at 16' but no cabinet enclosure information. <br />Please submit complete Valmont pole and luminaire arm shop <br />drawing that shows the enclosure information shown on sheets <br />A3 and A4 and corroborate the information in the Valmont shop <br />5. Valmont has provided drawings with added <br />drawings. <br />detail for the luminaire arms. <br />5. The A series sheets show a truss style arm, which is the COE <br />preferred arm for this location, but there is no Valmont shop <br />drawing showing the details of the luminaire arm. Please submit <br />6. Complete Valmont poles drawings provided. <br />complete Valmont shop drawings showing the pole, luminaire <br />This site will specifically use Pole Item #9, 10' <br />arm, and all relevant pole, arm, and pole associated equipment <br />luminaire arm with a 30' fixture mounting <br />details. <br />height. <br />6. Sheet IL 2 calls for a 10' mast arm length, but several mast arm <br />lengths are shown on this Valmont shop drawing. Please submit <br />7. This has been updated on the latest Valmont <br />a complete set of Valmont shop drawings that show data and <br />drawings. <br />details for a 10' truss style luminaire arm. <br />7. Sheet A3 notes that the pole finish should be hot dipped <br />galvanized, however the Valmont shop drawings are still showing <br />a finished paint galvanized system. Please submit complete <br />8. Complete Valmont poles drawings provided. <br />Valmont pole and luminaire arm shop drawings with a finishing <br />system of Galvanized (GV) with a finish coat = none and a color = <br />g Done <br />none <br />8. The Valmont shop drawing submitted says it is sheet 1 of 4. <br />Please submit the full set up Valmont shop drawings for the <br />10. Done <br />pole, luminaire arm and any other related details as missing <br />pages may include the following missing information. <br />11. Done <br />9. Please submit Valmont shop drawings that include an ID tag, <br />and ID tag detail. <br />10. Please submit Valmont shop drawings with notes that <br />include what standards this design is based on. <br />11. Please submit Valmont shop drawings that include the full <br />theoretical weight loading for the antenna and any associated <br />enclosures or equipment. <br />Page 8 of 10 <br />