Laserfiche WebLink
EVERETT 2044 <br />DEVELOPMENT REGULATIONS <br /> <br /> <br />6/17/2025 <br />DEVELOPMENT REGULATIONS <br />Page 142 <br />Figure 12-6 9-13: Transparency Requirements 1 <br /> 2 <br /> 3 <br />19.09.260 12.140 SPECIAL DESIGN STANDARDS 4 <br />The following site and design requirements apply to development that includes one or more of the 5 <br />design features in subsectfon (A), (B) or (C) of this sectfon, or where development abuts a residentfal 6 <br />zone along a rear property line, as required under subsectfon (D) of this sectfon. 7 <br />A. Building Entrances. Applies to Metro Everett and NB zones only. The main entrance to each structure 8 <br />must face the street, courtyard, or plaza. The entfre width of main entrances shall incorporate weather 9 <br />protectfon as outlined in Table 12-4 9-5 and EMC 19.12.120 19.09.240. 10 <br />B. Recessed Entries. Applies to Metro Everett and NB zones only. 11 <br />1. Any entrance that is set back more than three feet from the front building facade shall 12 <br />comply with the standards set forth in Table 12-5 9-6 below. 13 <br />Table 12-5 9-6: Recessed Entries 14 <br />Standard Illustratfon Measurement <br />Width of <br />Recessed Entry <br />A 3 feet minimum. <br />Where depth exceeds <br />4 feet, width shall be <br />2x depth. <br />Depth of <br />Recessed Entry <br />B 3 feet minimum