Bayley Construction LP 6/18/2025
>
Contracts
>
Capital Contract
>
Capital Construction Contracts and Change Orders
>
Bayley Construction LP 6/18/2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/3/2025 10:03:31 AM
Creation date
7/3/2025 9:59:54 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
Bayley Construction LP
Approval Date
6/18/2025
Council Approval Date
6/11/2025
Department
Administration
Department Project Manager
Scott Pattison
Subject / Project Title
Outdoor Event Center - Design Phase 1A of the project
Tracking Number
0004869
Total Compensation
$2,901,602.00
Contract Type
Capital Contract
Contract Subtype
Capital Construction Contracts and Change Orders
Retention Period
10 Years Then Transfer to State Archivist
Imported from EPIC
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
174
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
Mr. Seth Cirrotti-Caruso <br />Cochran Electric <br />April 1, 2025 <br />Page 3 <br /> <br /> <br />ASSUMPTIONS, EXCLUSIONS AND EXCEPTIONS <br />1. This proposal assumes that all electrical engineering will be completed at the same time <br />and there will be no phasing within the project scope. <br />2. This proposal is based on a Construction Cost of no more than $55 million. If the GMP final <br />approved construction cost exceeds that value Coffman will require additional services. <br />3. The facility will not be designed to NetZero or Living Building standards. <br />4. Specification and placement of all site, stadium, and field luminaires assumed to be by <br />others and excluded. <br />5. Design work for duct bank routing, utility poles, utility vaults, and other infrastructure <br />associated with the electrical utility upstream of the utility transformer is assumed to be by <br />the Civil Engineer. Coffman will show general routing for reference. <br />6. Design of all low-voltage systems (telecommunications, AV, fire alarm, building controls, <br />etc.) are excluded unless specifically indicated as being provided by Coffman under the <br />Scope of Work above. Coffman will coordinate with the low-voltage designer to provide <br />120V and higher voltage power to the low-voltage system equipment. <br />7. This proposal covers the design of the initial facility and does not include work associated <br />with the buildout for future tenant improvements for concessions or other tenants that will <br />be designed into the facility after Design Development phase. <br />8. Effort associated with Value Engineering after the 100% DD phase is excluded. <br />9. Effort associated with commissioning and performance testing are excluded from this <br />proposal. <br />10. The project is anticipated to be LEED certified. Documentation and submission for LEED <br />credits will be by others. Coffman will work to provide an electrical design that <br />accommodates credits noted under the Scope of Services. Other credits, including credits <br />associated with renewable energy, are excluded from this proposal. <br />11. The project will be designed in Revit to a LOD of 200. Coffman’s modeling will be limited to <br />the electrical distribution equipment. Modelling of feeders, branch circuits, cable trays, <br />conduit racks, and other systems are excluded. Coffman’s model will be utilized for spacing <br />planning purposes only and the final installation modeling, construction clash detection, and <br />other modeling to support construction activities will be by Cochran Electric. <br />12. Coffman will provide preliminary fault current calculations as required for permitting <br />purposes. Final fault current calculations, arc flash and coordination studies will be by <br />others. <br />13. Photovoltaic systems, if required, will be design-build by the photovoltaic installer. Coffman <br />will coordinate system size and pathway back to the main service. <br />14. Design associated with generator fueling systems other line voltage power required to fuel <br />pumps and ancillary equipment is excluded. <br />15. Coffman will receive frozen architectural backgrounds (walls, doors, and RCPs locked) and <br />mechanical/plumbing electrical coordination drawings 15 business days prior to the <br />milestone submittals noted above. Changes that occur after receiving the backgrounds may <br />Design-Build Contract for Everett Outdoor Events Center <br />Exhibit C - Phase 1A Work and Fee Proposal
The URL can be used to link to this page
Your browser does not support the video tag.