<br />www.RedHawkFireProtection.com Page 3 of 3 <br />Conditions <br />1. All work is to be performed during normal working hours (6:00 a.m. - 6:00 p.m.) unless other <br />arrangements are made. <br />2. Work area to be always accessible. <br />3. Water to be installed to riser room prior to any testing of the fire sprinkler system. <br />4. The pendent sprinklers shall be centered in ceiling tile modules in the 2-0 direction. <br />5. Sprinklers are to be installed to provide adequate coverage per code. Single sprinklers will not <br />necessarily be centered, or symmetrical with respect to lights, diffusers, smoke detectors, etc. <br />Sprinklers will be symmetrically aligned in corridors. <br />6. Drain piping to be run to an open-air discharge point within ten feet of the drain valve or device served. <br />7. This proposal is based upon installation being made from finished unobstructed concrete floors by using <br />A-ladder, forklift, or scissor lift at Red Hawk Fire Protection, LLC’s option. <br />8. This proposal is based on Red Hawk Fire Protection, LLC receiving AUTOCAD backgrounds from all <br />trades in a timely manner, without cost. <br />9. It is the owner’s responsibility to maintain adequate heat in all areas protected by the wet pipe sprinkler <br />system. <br />10. The construction standpipes are permanent standpipes. The stairs must be constructed and <br />keep pace with the building erection for the installation of the standpipe system will be aligned <br />with the construction standpipe requirements. <br />11. Material pricing is based on the current market with 5% escalation. Should material pricing, <br />specifically steel pipe, exceed this factor, RHFP will be compensated for the increases. <br /> <br />Exclusions <br />1. Fire sprinklers above finished ceiling area. If a heat detection system is required additional sprinklers <br />above these areas may be used for this requirement and they would be installed as an extra to our <br />original contract price. <br />2. Fire sprinkler head layout does not include ceiling fans or potential future ceiling fans. <br />3. FPE - Fire Protection Engineer stamp or review. <br />4. Seismic structural and civil review by professional engineer and modifications to the building structure. <br />5. All painting desired or required, including cleaning of piping, and protection of the installed sprinkler <br />heads from paint. <br />6. All electrical wiring of any kind. Including work necessary to place specified electronic alarms in service <br />including supervisory alarm system, central station monitoring and fire life safety systems and 120 VAC <br />power to the control panels or air compressor. <br />7. Pre-action systems. <br />8. Clean Agent systems. <br />9. Hood suppression systems. <br />10. Pipe identifications except that required by NFPA code. Pipe markings for exposed standpipes in <br />egress pathways. <br />11. Underground piping beyond 5 feet on the building. <br />12. Underground excavation and backfill. <br />13. Sleeves or caulking of sleeves. <br />14. Cost of bond <br />15. Water Storage tank <br />16. Fire Pump transfer switch in not required or included. <br />17. Beam penetrations. <br />18. Permanent or temporary fire extinguishers and cabinets. <br />19. Heat tape and insulation of fire mains. <br /> <br /> <br />Design-Build Contract for Everett Outdoor Events Center <br />Exhibit C - Phase 1A Work and Fee Proposal