Program Summary
<br />Everett Multipurpose Stadium
<br />Everett, WA
<br />March 2025
<br />7.0 TEAM / EVENT FACILITIES
<br />Class
<br />No.Space Type Units SF Total SF Description USL MiLB
<br />7.1 HOME CLUBHOUSE 4,950
<br />7.1.1 Team Dressing Area (Men & Women)2 700 1,400 Provide minimum twenty (20) 24"x72" lockers + coaches writing board / screen
<br />7.1.2 Toilet Room 2 300 600 Provide 6 water closets, 4 lavs.
<br />7.1.3 Shower Room 2 180 360 Provide 6-8 showerheads.
<br />7.1.4 Drying Area 2 120 240 Locate adjacent to Shower Room.
<br />7.1.5 Custodial Closet 2 50 100 Locate adjacent to Shower & Toilet Rooms.
<br />7.1.6 Training Room 1 400 400 Provide training equipment, tables, and ice bath --Storage. Shared between M & W
<br />7.1.7 Trainer's Office 1 150 150 Shared between M & W.
<br />7.1.8 Coaches' Locker Room (M & W)2 200 400 Provide Six (6) 24"x72" lockers
<br />7.1.9 Coaches' Toilets and Showers 2 250 500 Provide 1 urinal, 1 water closet, 2 lavs, 3 shower hds
<br />7.1.10 Manager's Office 0 200 0 Provide desk and small conference table - 6-8 in meeting.
<br />7.1.11 Manager's Toilet and Shower 0 130 0 Provide one (1) 30"x72" locker, 1 urinal, 1 water closet, 1 shower
<br />7.1.12 Team Lounge Area 0 300 0
<br />Include meal serving area kitchenette area (elec. range w/oven & hood, 21 cf refrig,
<br />DW, kit sink w/disposal, and trash compactor.
<br />7.1.13 Team Dietician Office 0 150 0 Dietician's Office
<br />7.1.14 Equip Manager Storage/Kitchen 0 300 0 Locate with direct access to Locker Room.
<br />7.1.15 Team Storage 2 200 400 Team Storage
<br />7.1.16 Laundry Room 1 200 200 Locate adj to Equip Mgr/Stor. (1) 50 Lb Washers (1) 70 Lb Dryer.
<br />7.1.17 Weight Room 0 750 0 Visible from Strength Coach's Off. Shared between home / visitors
<br />7.1.18 Weight Room strength coach office 0 150 0 View to weight room -- storage for supplements
<br />7.1.19 Family Waiting Area w/ RR 0 300 0 Locate w/ direct access to Lobby area, near Team Dress Room.
<br />7.1.20 Video Coaching Area/Conf Room 1 200 200
<br />7.2 MULTI-PURPOSE ROOM 0
<br />7.2.1 Warm-up / Cool down 0 250 0 Near changing area, durable materials, flexible space. Use hitting tunnel area.
<br />7.3 MASCOT / STAR DRESSING AREA 0
<br />7.3.1 Dressing Room 0 80 0 Combine in one locker room/well ventilated
<br />7.3.2 Toilet / Shower Room 0 70 0
<br />7.4 VISITOR CLUBHOUSE 0
<br />7.4.1 Team Dressing Area 0 700 0 Shared with MiLB
<br />7.4.2 Toilet Room 0 300 0 Provide 6 water closets, 4 lavs.
<br />7.4.3 Shower Room 0 180 0 Provide 6-8 showerheads.
<br />7.4.4 Drying Area 0 100 0 Locate adjacent to Shower Room.
<br />7.4.5 Custodial Closet 0 50 0 Locate adjacent to Shower & Toilet Rooms.
<br />7.4.6 Training Room 0 200 0 Provide space for training tables
<br />7.4.7 Trainers Office 0 100 0 Provide office for trainer
<br />7.4.8 Coaches' Locker Room 0 200 0 Provide Six (6) 24"x72" lockers
<br />7.4.9 Coaches' Toilets and Showers 0 250 0 Provide 1 urinal, 1 water closet, 2 lavs, 3 shower hds
<br />7.4.10 Manager's Office 0 150 0 Provide one (1) 36"x72" locker and desk. -- 36"x72"
<br />7.4.11 Team Lounge Area 0 300 0
<br />Include small kitchenette area (elec. range w/oven & hood, 21 cf refrig, DW, kit sink
<br />w/disposal, and trash compact.
<br />7.5 ADDITIONAL ROOMS 350
<br />7.5.1 Auxiliary Locker Room 0 200 0 Provide twenty (20) 18"x72" lockers Opportunity for expanded flexibility.
<br />7.5.2 Toilet / Shower Room 0 150 0 Provide 3 urls, 3 wcs, 4 lavs, 6 shwr heads
<br />7.5.3 Custodial Closet 0 50 0 Locate adjacent to Shower & Toilet Rooms.
<br />7.5.4 Medical Room 1 250 250 Locate adjacent to locker rooms, field access, gurney, exam table, millwork
<br />7.5.5 Toilet Room 1 100 100 Locate adjacent Medical Room
<br />7.6 OFFICIALS' FACILITIES 0
<br />7.6.1 Officials' Locker Room 0 200 0 Included in MiLB Program. Provide five (5) 24"x72" lockers. Shared w/ MiLB
<br />7.6.2 Officials' Toilet/Shower 0 150 0 Provide 2 water closet, 2 lavs, 2 shower heads.
<br />7.6.3 Custodial Closet 0 50 0 Locate adjacent to Shower & Toilet Rooms.
<br />7.7 FIELD ACCESS WAYS 0
<br />7.7.1 Player FIeld Access 0 1,000 0 Provide enclosed access from Clubhouses to Field.
<br />7.7.2 Officials Field Access 0 1,000 Provide enclosed access from Officials' Facilities to Playing Field.
<br />7.7.3 Public Field Access 0 1,000 0 Prov. enclosed access with disabled stg access/umpire access
<br />Total - Enclosed Areas 5,300
<br /> Net to gross 25%1,330
<br />TOTAL 6,630 GSF
<br />8.0 PLAYING FIELD FACILITIES
<br />Class
<br />No.Space Type Units SF Total SF Description USL MiLB
<br />8.1 PLAYING FIELD 100,000
<br />8.1.1 Playing Field 1 100,000 Natural Grass or FIFA 2-star level approved synthetic turf
<br />8.1.2 Playing Field Dimensions Comply with FIFA preferred: 75 yards wide X 120 yards long
<br />8.2 FIELD AMENITITES 0
<br />8.2.1 Field Toilet 0 80 0 Toilet located close proximity to field and players benches
<br />8.4 FIELD EQUIPMENT 0
<br />8.4.1 Field Equipment Storage 0 1,000 0 Outdoor area
<br />8.5 SPORTS LIGHTING
<br />8.5.1 Sports Lighting System USL standards as minimum - 125 fc Horiz, Main, Rev cams, 75 fc End cams
<br />Total - Enclosed Areas 0 NSF
<br /> Net to gross 10%0 SF
<br />Total - Outdoor Areas 100,000 SF
<br />TOTAL 100,000 GSF
<br />3/6/2025 Page 5 of 7
<br />Design-Build Contract for Everett Outdoor Events Center
<br />Exhibit B - Owner's Initial Project Program
|