Program Summary <br />Everett Multipurpose Stadium <br />Everett, WA <br />March 2025 <br />9.0 SERVICE & OPERATIONS FACILITIES <br />Class <br />No.Space Type Units SF Total SF Description USL MiLB <br />9.1 STADIUM PERSONNEL FACILITIES 0 <br />9.1.1 Entrance/Security 0 200 0 Provide direct access to toilets./150sf security office <br />9.1.2 Toilet Room - Women 0 150 0 Provide 2 water closets, 2 lavs. <br />9.1.3 Toilet Room - Men 0 150 0 Provide 1 urinal, 1 water closet, 2 lavs. <br />9.1.4 Break Room 0 200 0 Provide indoor or covered outdoor space screened from ticket holders <br />9.2 STORAGE 1,200 <br />9.2.1 Promotions Storage <br />9.2.1.a Promo Storage 0 80 0 Locate at each entry for storage of game-day promotions/program storage. <br />9.2.1.b Field Promo Storage 0 200 0 Locate with direct access to field. <br />9.2.2 General Storage <br />9.2.2.a Concourse General Storage 0 200 0 Locate one (1) each on 1st and 3rd base sides. <br />9.2.2.b Suite Level General Storage 0 120 0 Locate one (1) each on 1st and 3rd base sides. <br />9.2.2.c Concourse Group Sales Stor.0 200 0 Locate one (1) adjacent to Group Sales Area. <br />9.2.2.d Picnic Area Storage 0 200 0 Locate adjacent to Picnic Area. <br />9.2.2.e Kid's Play Area Storage 0 200 0 Locate adjacent to Kid's Play Area. <br />9.2.2.f Attic Stock 0 200 0 Locate adj to Field Maint Area. Store surplus seating parts, etc. <br />9.2.2.g Promotor Storage 1 200 200 Locate with concourse access <br />9.2.2.g Enclosed Field Equipment 1 1,000 1,000 Locate with direct access to field. <br />9.3 LOADING DOCK 0 <br />9.3.1 Loading Dock 0 800 0 Area for truck loading/unloading. <br />9.3.2 Trash Compactor Room 0 700 0 Enclosed and air-conditioned room. Adjacent to Loading Dock. <br />9.3.3 Recycling Bins 0 500 0 Enclosed area. Locate adjacent to Trash Compactor Room. <br />9.4 TV VAN PARKING 0 <br />9.4.1 TV Van Parking 0 3,000 0 Locate adjacent to stadium, as close to Press Facilities as possible. <br />9.5 STADIUM / FIELD MAINTENANCE/STORAGE 0 <br />9.5.1 Maintenance Shop/Custodial Storage 0 1,500 0 <br />9.5.2 General Storage 0 200 0 See by level <br />9.5.3 Field Maintenance Storage 0 400 0 Tool Storage <br />9.5.4 Custodial Maintenance Office 0 120 0 <br />9.5.5 Break Room 0 100 0 <br />9.5.6 Groundskeeping Office 0 120 0 <br />9.5.7 Maint./Grounds. Lockers 0 250 0 6-8 lockers with integral combination lock <br />9.5.8 Maint./Grounds. Break Room 0 200 0 Casework with sink <br />9.5.9 Toilet / Shower Room 0 120 0 2 water closets, 2 lavs, 2 individual showers/drying area <br />9.5.10 Bin Storage 0 200 0 Located at Field Maint. Shop <br />9.6 M/E/P FACILITIES 675 <br />9.6.1 Mechanical <br />9.6.1.a Mechanical Space 1 250 250 Initial area assumed to be 4% of net building area - distributed appropriately. <br />9.6.2 Electrical <br />9.6.2.a Main Electrical Room 0 350 0 Location to be determined. <br />9.6.2.b Emergency Electrical Room 0 100 0 Location to be determined. <br />9.6.2.c Secondary Electrical Room 1 90 90 Location to be determined. <br />9.6.2.d Elevator Machine Room 0 100 0 Locate one (1) adjacent to each elevator - public and service. <br />9.6.2.e Show Power Provide Show Power capabilities. Assume stage at outfield <br />9.6.2.f Fire and Security System Provide Fire and Security Systems. <br />9.6.3 Plumbing <br />9.6.3.a Fire Pump Room 0 150 0 Location to be determined. <br />9.6.3.b Water Heater Room 1 200 200 Location to be determined. <br />9.6.4 Telecommunications <br />9.6.4.a Main Telecom Room 0 150 0 Location to be determined. <br />9.6.4.b Secondary Telecom Room 1 85 85 Location to be determined. <br />9.6.4.c Fiber Optic Connectivity Provide connectivity for offices, concessions, ticketing, gift shop, press box, etc. <br />9.6.5 Audio/Visual <br />9.6.5.a Sound Rack / A/V 1 50 50 Location to be determined. <br />Total - Enclosed Areas 1,875 NSF <br /> Net to gross 20%380 SF <br />Total - Outdoor Areas 0 SF <br />TOTAL 2,255 GSF <br />10.0 SOUND SYSTEM & SCOREBOARD <br />Class <br />No.Space Type Units SF Total SF Description USL MiLB <br />10.1 SCOREBOARD 0 <br />10.1.1 Main Scoreboard 1 0 0 Relocated from Funko Field. No part of scoreboard within 50' of centerline of field. <br />10.2 SOUND SYSTEM 0 <br />10.2.1 Sound System 1 0 0 Provide distributed sound system throughout entire stadium. Areas to serve include: <br />- Entrances - Kids' Play Area <br />- Seating Bowl - Administrative Offices <br />- Seating Berm - Novelty Store <br />- Suites - Public Toilets <br />- Party Decks - Press Box <br />- Outdoor Bar <br />3/6/2025 Page 6 of 7 <br />Design-Build Contract for Everett Outdoor Events Center <br />Exhibit B - Owner's Initial Project Program