Bayley Construction LP 6/18/2025
>
Contracts
>
Capital Contract
>
Capital Construction Contracts and Change Orders
>
Bayley Construction LP 6/18/2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/3/2025 10:03:31 AM
Creation date
7/3/2025 9:59:54 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
Bayley Construction LP
Approval Date
6/18/2025
Council Approval Date
6/11/2025
Department
Administration
Department Project Manager
Scott Pattison
Subject / Project Title
Outdoor Event Center - Design Phase 1A of the project
Tracking Number
0004869
Total Compensation
$2,901,602.00
Contract Type
Capital Contract
Contract Subtype
Capital Construction Contracts and Change Orders
Retention Period
10 Years Then Transfer to State Archivist
Imported from EPIC
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
174
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
Page 4 <br /> <br /> <br />Design Phase: <br />1. Issue Cx specifications for inclusion in bid/permit Documents to include monitoring-based Cx <br />requirements. <br />Occupancy Phase: <br />1. Development of Monitoring Based Commissioning Plan. <br />a. The monitoring-based commissioning plan will document roles and responsibilities; <br />measurement requirements (meters, points, metering systems, data access); the <br />points to be tracked, with frequency and duration for trend monitoring; the limits of <br />acceptable values for tracked points and metered values (where appropriate, <br />predictive algorithms may be used to compare ideal values with actual values); the <br />elements used to evaluate performance, including conflict between systems, out-of- <br />sequence operation of systems components, and energy and water usage profiles; an <br />action plan for identifying and correcting operational errors and deficiencies; training <br />to prevent errors; planning for repairs needed to maintain performance; and the <br />frequency of analyses in the first year of occupancy (at least quarterly). <br />2. Review Systems Manual to include Monitoring Based Commissioning needs. <br />3. Collect the first twelve (12) months of electrical and natural gas utility data and benchmark <br />facility performance in an associated report. <br />LEED BD+C: New Construction – Energy & Atmosphere – Envelope Commissioning (2 Points): <br />Where Building Enclosure Commissioning (BECx) is included, DLR Group to provide commissioning services <br />for the building’s thermal envelope in accordance with ASHRAE Guideline 0 –2005 and the National <br />Institute of Building Sciences (NIBS) Guideline 3–2012, Exterior Enclosure Technical Requirements for the <br />Commissioning Process, as they relate to energy, water, indoor environmental quality, and durability. <br />Design Phase <br />1. Review and document the OPR and BECx plan. <br />2. Provide a design review of the enclosure related drawings and specifications at the CD phase. <br />3. Provide a building enclosure commissioning specification for inclusion in the design documents. <br />Construction Phase: <br />1. Review contractor submittals pertaining to the building enclosure. <br />2. Verify systems manual updates and delivery to include BOD, warranties, and O&M manuals. <br />3. Verify operator and occupant training delivery and effectiveness. <br />4. Issue building envelope construction checklists. <br />5. Provide twelve (12) observational site visits to observe installation of the building enclosure. Site <br />visits are to be coordinated with the construction manager and Owner. Site visits are <br />recommended for the beginning and near completion stages of air/vapor barrier installations, <br />curtain wall installations, window installations, roof system installations, and any other project <br />specific systems pertaining to the building enclosure and related performance. <br />6. Provide a written field report disclosing the findings of the quality observations. <br />7. The BECxA shall provide an Issues Log. The Issues Log will be maintained on the field reports. <br />Occupancy Phase: <br />1. Perform seasonal testing pertaining to any infrared scanning that may be performed. <br />2. Perform a 10-month post-occupancy review of the building enclosure and provide a report. <br />3. Report on any infrared scanning performed by a third party. <br />4. Report on any water hose testing performed by a third party <br />Design-Build Contract for Everett Outdoor Events Center <br />Exhibit C - Phase 1A Work and Fee Proposal
The URL can be used to link to this page
Your browser does not support the video tag.