My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8407 BROADWAY SECURE SPACE STORAGE 2025-08-19
>
Address Records
>
BROADWAY
>
8407
>
SECURE SPACE STORAGE
>
8407 BROADWAY SECURE SPACE STORAGE 2025-08-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2025 11:40:29 AM
Creation date
7/17/2025 1:45:01 PM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
8407
Tenant Name
SECURE SPACE STORAGE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
277
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Broadway Everett Expansion Storm Drainage Report <br /> November 16, 2022 <br /> 2.0 - MINIMUM REQUIREMENTS <br /> The design of the facilities on site conforms to Chapter 4 of the "Design and Construction Standards and <br /> Specifications" and the "2019 Stormwater Management Manual for Western Washington". <br /> Minimum Requirements Analysis <br /> The site proposes 25,136 sf of new plus replaced hard surface which includes 23,319 sf of proposed <br /> building roof and 1,817 sf of impervious concrete walkway. Minimum Requirement#1 through #9 apply to <br /> this project. <br /> See Appendix A— Hard Surface Summary for Proposed Design. <br /> See Flow Chart below for more details on minimum requirements selection process. <br /> Does the Project result in 2,000 square feet,or more,of new plus replaced hard surface area? <br /> OR <br /> Does the land disturbing activity total 7,000 square feet or greater? <br /> Yes I lNo <br /> Minimum Requirements#1 through#5 <br /> apply to the new and replaced hard Minimum Requirement#2 applies. <br /> surfaces and the land disturbed. <br /> Does the Project add 5,000 square feet or more of new hard surfaces? <br /> OR <br /> Convert%acres or more of vegetation to lawn or landscaped areas? <br /> OR <br /> Convert 2.5 acres or more of native vegetation to pasture? <br /> Yes No <br /> All Minimum Requirements apply Next Question <br /> to the new hard surfaces and the Is this a road <br /> converted vegetation areas. <br /> elated project? NO <br /> Yes <br /> Does the Project add 5,000 square feet or more of new hard surfaces? <br /> Yes NO Is the total of new plus replaced hard sudaoes 5.000 <br /> square feet or more, <br /> Do the new hard AND <br /> surfaces add 50°/or Np No additional NO does the value of the proposed Improvements- <br /> urfa l0 the existing <br /> including interior improvements-exceed 50%of the <br /> morhard to <br /> within requl rements. assessed value(or replacement value)of the. <br /> the Slle? • ezlsting ProJect She Improvements(for <br /> commercial or Industrial projects)OR <br /> . exlstng She Improvements(for all other projects) <br /> Yes �[Allum Requirements apply to the new and replaced <br /> d surfaces and converted vegetation areas. Yes <br /> Flow Chart for Determining Requirements for <br /> loom Redevelopment <br /> Revised March2019 <br /> DEPARTMENT OF <br /> ECOLOGYPlease see http.IAvww.ecy wa.gowcopynghthrml for copy fight notice including permissions <br /> State of Washingtoni limitation of liability,and disclaimer. <br /> Figure 2— Minimum Requirement Flow Chart <br /> Page 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.