My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7100 HARDESON RD 2021 Plans 2025-09-11
>
Address Records
>
HARDESON RD
>
7100
>
Plans
>
7100 HARDESON RD 2021 Plans 2025-09-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2025 1:44:11 PM
Creation date
8/7/2025 10:38:23 AM
Metadata
Fields
Template:
Address Document
Street Name
HARDESON RD
Street Number
7100
Permit
M2101-014
Year
2021
Notes
MECHANICAL FOR RENOVATION AND ADDITION - VEHICLE MAINT FAC
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
158
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC DUCT SPECIFICATION(WSEC) <br /> SEISMIC <br /> DUCT SYSTEM PRESSURE CLASS DUCT MATERIALS FITTINGS FLEX CONNECTION SEAL CLASS CLEANLINESS DURING IMPORTANCE NOTES <br /> FLEX DUCT CONSTRUCTION MATERIALS FACTOR <br /> HVAC LOW PRESSURE SUPPLY; SMACNA+12'OR+1"PRESSURE GALVANIZED DUCT;GAUGE AND ELBOWS:PURCHASED ADJUSTABLE ELBOWS F MAXIMUM LENGTH WITH NO OFFSETS SMACNA SEAL CLASS FOLLOW BASIC"LEVEL A"SMACNA PROVIDE 1"INTERIOR LINING WHERE IP=10 <br /> REINFORCEMENT SHALL BE SMACNA IN ACCORDANCE WITH SMACNA+1" USE THERMA FLEX,GKM OR EQUAL LEVEL C SMACNA INDICATED ON PLANS <br /> OR BETTER STANDARDS ill"NO SEAL <br /> SMACNA+12POR+1"PRESSURE SMACNA+I2POR+1"PRESSURE SMACNA+12POR+1"PRESSURE <br /> ROUND MAY BE SNAPLOCK LARGER THAN 24INCHES <br /> CONICAL SPIN-IN FITTINGS ON ROUND <br /> BRANCHED DUCTS <br /> OUTSIDE AIR INTAKE SMACNA+2" GALVANIZED DUCT;GAUGE AND ELBOWS:PURCHASED ADJUSTABLE ELBOWS FLEX AT EQUIPMENT CONNECTIONS TO SMACNA SEAL CLASS FOLLOW BASIC"LEVEL A" PROVIDE 1"INTERIOR LINING WHERE IP=10 <br /> LOUVER/PLENUMS REINFORCEMENT SHALL BE SMACNA IN ACCORDANCE WITH SMACNA+1" COMPLY WITH SPEC APPLICABLE PRESSURE LEVEL C SMACNA INDICATED ON PLANS <br /> DUCT UPSTREAM OF MOTORIZED OR BETTER STANDARDS CLASS <br /> DAMPERS RECTANGULAR MAY BE S DRIVE CL RADIUS OF 1.0 DIAMETER ON DUCTS <br /> ROUND MAY BE SNAPLOCK LARGER THAN 24INCHES <br /> CONICAL SPIN-IN FITTINGS ON ROUND <br /> BRANCHED DUCTS <br /> EXHAUST SMACNA-tl2"OR-1"PRESSURE GALVANIZED DUCT;GAUGE AND ELBOWS:PURCHASED ADJUSTABLE ELBOWS F MAXIMUM LENGTH WITH NO OFFSETS SMACNA SEAL CLASS FOLLOW BASIC"LEVEL A" PROVIDE 1"INTERIOR LINING WHERE IP=10 <br /> LOW PRESSURE REINFORCEMENT SHALL BE SMACNA IN ACCORDANCE WITH SMACNA+1" USE THERMA FLEX,GKM OR EQUAL LEVEL C SMACNA INDICATED ON PLANS <br /> OR BETTER STANDARDS FLEX AT EQUIPMENT CONNECTIONS TO <br /> RECTANGULAR MAY BE S DRIVE CL RADIUS OF 1.0 DIAMETER ON DUCTS COMPLY WITH SPEC APPLICABLE PRESSURE <br /> ROUND MAY BE SNAPLOCK LARGER THAN 24INCHES CLASS <br /> CONICAL SPIN-IN FITTINGS ON ROUND <br /> BRANCHED DUCTS <br /> VOLUME DAMPERS NIA SMACNA REQUIREMENTS NIA NIA PERAPPLICABLE PERAPPLICABLE NIA NIA <br /> DUCT SYSTEM DUCT SYSTEM <br /> DUCT INSULATION SCHEDULE GRILLE,REGISTER,DIFFUSER SCHEDULE <br /> DUCT TYPE DUCT LOCATION INSULATION OTHER REQUIREMENTS MARK TYPE MANUFACTURER MODEL MATERIAL FACE SIZE CONNECTION MNT'G FINISH REMARKS <br /> R-VALUE SIZE <br /> NOT WITHIN CONDITIONED SPACE: D1 SUPPLY AIR DUCT DIFFUSER TITUS 132RS STEEL 38"x14" 36"x12" DUCT WHITE <br /> SUPPLY,RETURN ON EXTERIOR OF BUILDING,ON ROOF,IN ATTIC IN ENCLOSED CEILING R-7 APPROVED WEATHER PROOF BARRIER <br /> SPACE,IN WALLS,IN GARAGE,IN CRAWL SPACES. D2 SUPPLY AIR CEILING DIFFUSER TITUS MCD STEEL 18"x18" 10"0 LAY-IN WHITE <br /> OUTSIDE AIR INTAKE WITHIN CONDITIONED SPACE R-7 PER THE 2015 WSEC C403.2.8.1 D3 SUPPLY AIR CEILING DIFFUSER TITUS MCD STEEL 24"44" 170 LAY-IN WHITE <br /> D4 SUPPLY AIR SIDEWALL GRILLE TITUS 30ORS STEEL 12"x12" 12"x12" SURFACE WHITE <br /> SUPPLY,RETURN, NOT WITHIN CONDITIONED SPACE: R5 3 D5 SUPPLY AIR DUCT GRILLE TITUS 30ORS STEEL 18"xl2" 18"xl2" DUCT WHITE <br /> OUTSIDE AIR INTAKE IN CONCRETE,IN GROUND D6 SUPPLY AIR CEILING DIFFUSER TITUS MCD STEEL 12"x12" 6"0 LAY-IN WHITE <br /> SUPPLY WITH SUPPLY AIR TEMPERATURE WITHIN CONDITIONED SPACE R-3.3 D7 SUPPLY AIR SIDEWALL GRILLE TITUS 30ORS STEEL 12"x8" 12"x8" SURFACE WHITE <br /> <55°F OR>105°F <br /> D8 SUPPLY AIR CEILING DIFFUSER TITUS MCD STEEL B"x6" 6"0 SURFACE WHITE <br /> NOTE: REQUIREMENTS APPLY TO THE DUCT TYPE LISTED,WHETHER HEATED OR MECHANICALLY COOLED.MECHANICALLY COOLED DUCTS D9 SUPPLY AIR SIDEWALL GRILLE TITUS 30ORS STEEL 32"x16" 32"xl6" SURFACE WHITE <br /> REQUIRING INSULATION SHALL HAVE A VAPOR RETARDER,WITH A PERM RATING NOT GREATER THAN 0.5 AND ALL JOINTS SEALED. <br /> R1 RETURN AIR DUCT GRILLE TITUS 35ORS STEEL 86"x38" 84"46" DUCT WHITE <br /> R2 RETURN AIR CEILING GRILLE TITUS 50F STEEL 18"x18" 10"0 LAY-IN WHITE <br /> LOUVER SCHEDULE R3 RETURN AIR CEILING GRILLE TITUS 50F STEEL 24"44" 12"0 LAY-IN WHITE <br /> EQUIP TAG APPLICATION AIRFLOW(CFM) FREE AREA FREE AREA STATIC PRESSURE GROSS LOUVER MANUFACTURER&MODEL REMARKS R4 RETURN AIR DUCT GRILLE TITUS 35ORS STEEL 12"xl2" 12"x12" DUCT WHITE <br /> (SQ.FT.) VELOCITY(FPM) (IN W.G.) SIZE(IN) <br /> R5 RETURN AIR DUCT GRILLE TITUS 35ORS STEEL 18"x12" 18'k12" DUCT WHITE <br /> L-1 EXHAUST 1,000 5.32 188 <0.1 36x36 RUSKINELF375DX 1 <br /> IRS RETURN AIR CEILING GRILLE TITUS 50F STEEL 12"x12" 8"0 LAY-IN WHITE <br /> REMARKS: R7 RETURN AIR SIDEWALL GRILLE TITUS 35ORS STEEL I 12"xl2" 12"x12" SURFACE WHITE <br /> 1.SEE PLANS FOR QUANTITY. R8 RETURN AIR SIDEWALL GRILLE TITUS 350RS STEEL 37x16" 32"xl6" SURFACE WHITE <br /> El EXHAUST AIR CEILING GRILLE TITUS 50F STEEL 12"x12" 6"x6" SURFACE WHITE <br /> EX EXISTING GIRD NIA EXISTING TO REMAIN <br /> ELECTRIC WATER HEATER SCHEDULE <br /> EQUIP. MANUFACTURER ELECTRICAL WEIGHT, TEMP FLOW <br /> N0. TYPE SERVICE &MODEL VOLTS PHASE AMPS LBS DEGRISE E REMARKS F GPM <br /> EWH-1 INSTANTANEOUS TANKLESS WATER HEATER RESTROOMS EEMAXAM005240T 240 1 20 6 66 0.5 <br /> EWH-2 INSTANTANEOUS TANKLESS WATER HEATER MOP SINK EEMAXPR008240T 240 1 33 6 55 1.0 <br /> EWH-3 INSTANTANEOUS TANKLESS WATER HEATER BREAK ROOM EEMAXAM005240T 240 1 20 6 66 0.5 <br /> - NO. DATE REVISION MCOB MAINTENANCE IMPROVEMENTS DRAWN:BSS PROJECT NO.:20-002 <br /> 1 BE "NQ FACILITIES MASTERPLAN PHASE 3A DESIGNED:BSB DATE:APRIL 13,2021 <br /> 6" 4 <br /> 7100 HARDESON ROAD,EVERETT WA 98203 CHECKED:I WB ITS#2021-011 <br /> 1601 5th Avenue,Suite 1600 m i736 DRAWING NO.: R Seattle,WA.5822 1 �,c'4FcIVA " MECHANICAL SCHEDULES M 1 2-M V <br /> 206.622.6822 �SS7oNAL END\ Page 211 of 363 ■ <br /> www.kpH.com BOGARD ENGINEERS,PS <br />
The URL can be used to link to this page
Your browser does not support the video tag.