3003 W CASINO RD 2025 BLDG 40-53 Plans 2025-08-19
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-53
>
Plans
>
3003 W CASINO RD 2025 BLDG 40-53 Plans 2025-08-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2025 12:00:53 PM
Creation date
8/19/2025 12:00:39 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-53
Permit
FA2501-007
Year
2025
Notes
MONITOR WF AND TAMPER SWITCH WITH EXISTING FIRE ALARM
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(E.) POTTER VSR <br /> The Symbol of Protection Vane Type Waterflow Alarm Switch W/Retard <br /> Fig.2 Fig.3 Switch Terminal Connections <br /> To remove knockouts:Place screwdriver at Break out thin section of cover when wiring Clamping Plate Terminal <br /> inside edge of knockouts,not in the center both switches from one conduit entrance. <br /> / Fig.4 <br /> o � <br /> *�� <br /> �1 N <br /> OOINO <br /> Od1 DwG.#1146-16 <br /> AWARNING <br /> ® An uninsulated section of a single conductor should not be looped around <br /> the terminal and serve as two separate connections. The wire must be <br /> Do not drill into the base as this severed,thereby providing supervision of the connection in the event that <br /> creates metal shavings which can CDDWG.1146-13 the wire become dislodged from under the terminal. Failure to sever the <br /> create electrical hazards and damage wire may render the device inoperable risking severe property damage and <br /> the device.Drilling voids the warranty loss of life. <br /> Do not strip wire beyond 3/8"of length or expose an uninsulated <br /> conductor beyond the edge of the terminal block.When using stranded <br /> wire,capture all strands under the clamping plate. <br /> CONNECTOR <br /> BELL <br /> Typical Electrical Connections NEUrKALFROM D o BREAKER NEUTRAL FROM BELL <br /> Fig.S BREAKER <br /> Notes. LINE FROM BREAKER m EOL(End Of Resistor) <br /> 1. The Model VSR has two switches,one can be used to operate a central <br /> station,proprietary or remote signaling unit,while the other contact <br /> is used to operate a local audible or visual annunciator. <br /> 2. For supervised circuits,see"Switch Terminal Connections" NOTE: <br /> drawing and warning note(Fig.4). NhenconneCfngtoa0LL11ed <br /> control p,I,,f se thepanp <br /> o O e:ismr�ewemr�ir<nit:°Perin:ien. <br /> ul <br /> Testing <br /> The frequency of inspection and testing for the Model VSR and its associated protective monitoring system shall be in accordance with applicable NFPA <br /> Codes and Standards and/or the authority having jurisdiction(manufacturer recommends quarterly or more frequently). <br /> If provided,the inspector's test valve shall always be used for test purposes.If there are no provisions for testing the operation of the flow detection <br /> device on the system,application of the VSR is not recommended or advisable. <br /> A minimum flow of 10 GPM(38 LPM)is required to activate this device. <br /> Fig.6 Mounting Dimensions Fig. 7 GREEN GROUND <br /> 5.56 in SCREWS <br /> 3.50 in (141.2—) <br /> (89.0 mm) 2.00 in <br /> (50.8—) <br /> 2.34 in , <br /> (59.4 m±) <br /> U-BOLT P EDIA. Advise the person <br /> +5.25 in <br /> U-BOLT (+ 33.4—) responsible for testing of <br /> WASHER PIPE ER .�..- the fire protection system <br /> P "F"u.w�i" �p e <br /> SADDLE that this system must be <br /> Q tested in accordance with <br /> PIPE ® ® the testing instructions. <br /> PLASTIC <br /> P U <br /> gDpl,g wn.naata <br /> -30LT NOMINAL PIPE DIA.+1.75 in(+44.5 MM)FOR DN 50—DN 65 2-2.5 in <br /> NOMINAL PIPE DIA.+2.125 in(+54.0 MM)FOR DN 80—DN 200 3-8 in <br /> Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br /> 5401146-REV N • 10/21 PAGE 3 OF 5 <br />