My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2326 MCDOUGALL AVE 2025-09-12
>
Address Records
>
MCDOUGALL AVE
>
2326
>
2326 MCDOUGALL AVE 2025-09-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/12/2025 8:57:19 AM
Creation date
8/27/2025 11:00:37 AM
Metadata
Fields
Template:
Address Document
Street Name
MCDOUGALL AVE
Street Number
2326
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
106
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Option 3. Detention Design Worksheet <br /> Table 3: Small Project Detention Sizing <br /> Total Contributing Area to <br /> Detention System, (sf) Riser Height,overflow Riser Detention Detention Pipe <br /> Sizing Acres Orifice Size elevation above invert Diameter Pipe Diameter Length Required <br /> Selected At least but less than* (max) (in) of outlet pipe,(ft) (in) (in) (ft) <br /> 200 400 0.0092 0.375 1.5 6 18 20 <br /> 400 600 0.0138 0.375 1.5 8 18 24 <br /> 600 800 0.0184 0.375 1.5 8 18 28 <br /> 800 1000 0.0230 0.5 1.5 8 18 33 <br /> 1000 1200 0.0275 0.5 1.5 8 18 40 <br /> 1200 1400 0.0321 0.5 1.5 8 18 55 <br /> 1400 1600 0.0367 0.5 1.5 8 18 70 <br /> 1600 1800 0.0413 0.5 2.0 8 24 60 <br /> 1800 2000 0.0459 0.5 2.0 8 24 65 <br /> *For projects directing more than this total area draining to the detention facility, size using a continuous runoff model (WWHM, <br /> MGS Flood etc.). Do not use this table to size facility. <br /> Outlet pipe shall be set 3" above bottom of detention pipe to allow for sediment storage. <br /> • Net new impervious area requiring mitigation (ft): <br /> • Contributing impervious area to BMP: <br /> • Total contributing area including landscaped area (ft'): <br /> All underground stormwater facilities shall be setback from any structure or property line a distance equal to the depth of the <br /> ground disturbed in setting the structure. <br /> Applicable access requirements of DCSS 4-4.2 (3) have been met. <br />
The URL can be used to link to this page
Your browser does not support the video tag.