O GENERAL NOTES: <br /> O <br /> 1. WHEN STRANDED WIRE IS USED,ALL TERMINATIONS ARE MADE BY <br /> A PRESSURE TERMINAL,BY TAILING OFF WITH SOLID CONDUCTORS <br /> OR OTHER APPROVED MEANS OF TERMINATION. <br /> O / DS DS / 2. ALL CONDUCTORS ARE COPPER;TYPE THHN/THWN <br /> GFCI O --- 011 3. RATING OF STANDARD PANEL IS 22,000 A.I.C.44 4. WIRING METHOD IN METALLIC CONDUIT OR M.C.CABLE. <br /> I <br /> S. BREAKER LOCK OUT DEVICE SHALL BE INSTALLED ON ALL <br /> PERMANENTLY CONNECTED APPLIANCES.2020 NEC 422.31 <br /> -- 6. HVAC DISCONNECTS SHALL BE LABELED WITH AN IDENTIFICATION <br /> WP PLATE SHOWING CIRCUIT SOURCE PANELBOARD,CIRCUIT <br /> GFCI O WH _JD O NUMBER AND EQUIPMENT SERVED.WAC296-468-110022 <br /> o - — X <br /> 7. EXTERIOR WEATHER PROOF GFCI SHALL HAVE A"HEAVY DUTY" <br /> O WEATHER PROOF"IN USE'COVER.2020 NEC 406.9(B)(1) <br /> WALL MOUNTED 8. CONTROLLED RECEPTACLES SHALL BE LABELED PER 2020 NEC <br /> EXHAUST FAN 406.3(E)WITH THE TEXT"CONTROLLED"AND THIS SYMBOL (h <br /> TYP. OF 3 <br /> 9. THIS PLAN IS NOT AN"AS-BUILT'CIRCUITS MAY BE RUN DIFFERENT <br /> THAN SHOWN BASED ON OBSTACLES ENCOUNTERED. <br /> ELECTRICAL PLAN <br /> SCALE: 1/4"=T-0" ars I <br /> CUSTOMER APPROVAL <br /> ❑APPROVED <br /> ❑APPROVED EXCEPT AS NOTED <br /> ❑ REVISE AS NOTED AND RESUBMIT <br /> APPROVED By Date <br /> PRELIMINARY <br /> NOT FOR CONSTRUCTION <br /> ELECTRICAL SYMBOLS <br /> SYMBOL DESCRIPTION AFF <br /> TO TOP REMARKS <br /> ELECTRICAL PANEL <br /> B WEATHER PROOF 36 <br /> DUPLEX RECEPTACLE 20" 180 VA EACH <br /> CONTROLLED <br /> wp WEATHER RESISTANT GFCI 20" 1ED VA EACH <br /> wa RECEPTACLE <br /> EflD nLIGHT DIMMING CONTROL 48" 1 ZONE DIMMING CONTROL <br /> ,,T WALL MOUNT TIMER 48^ EXTERIOR LIGHTING CONTROL <br /> 7 DAY PROGRAMMABLE <br /> nUGHT PLUG LOAD CONTROL ABOVE CONTROLLED BY nUGHT ENABLED <br /> QTY. SIZE DESCRIPTION RELAY CEILING FIXTURE OCCUPANCY SENSORS <br /> ELECTRICAL PANEL 1 200 AMP SINGLE PHASE — NEMA 3R — 120/240 VOLT , PHONE/DATA ROUGH IN 4" 20" 3/4" FLEX STUBBED UP AND DOWN <br /> SO BOX w/SINGLE GANG MR <br /> HVAC 1 4 TON BARD 15 kW WALL HUNG HEAT PUMP 11 EER DS DOOR SWITCH - HVAC AS -Y4" FLEX CONDUIT FROM DOOR FRAME <br /> REQUIRED 15/2 TO HVAC UNIT <br /> HVAC CONTROLS 1 THERMOSTAT - BARD #8403-060 WALL HUNG HVAC UNIT AS REQUIRED SEE MECH SCHEDULE AND CAICS <br /> 1 TEMP SENSOR - BARD #8403-062 O HVAC THERMOSTAT 48" 4" SQUARE BOX w/SINGLE GANG MR18AWG STAT WIRE <br /> LIGHTING 3 2 x 4 LED TROFFER- nLIGHT ENABLED- 6000 LUMEN- 48 WATTS- 4000K nUGHT ENABLED LED TROFFER CEILING 48 VA EACH <br /> LITHONIA - 2BLT4 60L ADPT EZ1 LP840 N100 NES7ADCX PWS1836 w INTEGRAL SENSORS 6000 LUMEN EACH <br /> 14 WATT LED WITH VANDAL RESISTANT COVER AND INTEGRAL PHOTO CELL. FO LED WALL PACK 84" 14 VA EACH <br /> 1 CONTROLLED BY 7 DAY PROGRAMMABLE WALL TIMER FIELD SET FOR EXHAUST FAN - WALL MOUNT SEE <br /> BUSINESS HOURS. LITHONIA - OVWPLED4OK12OPEDDBHP17M4 g VA EACH <br /> 270 CFM - BROAN 508 A-3.1 <br /> EXHAUST FAN 3 270 CFM BROAN 508 - SWITCHED WITH LIGHTS IN RESTROOM ® REMOTE SENSOR 48" 4" SQUARE BOX w/SINGLE GANG MR <br /> 18AWC SHIELDED STAT WIRE <br /> 12-8-21 PRELIM REVIEW-DG dDGCOPYRIGHT 2021,BLAZER INDUSTRIES,INC. MOBILE ADARRfor: Approved for Const: Job No: 20080 <br /> THIS MATERIAL IS THE EXCLUSIVE PROPERTY <br /> OF BLAZER INDUSTRIES,INC.AND SHALL ■■ Flle Copy: <br /> NOT BE REPRODUCED,USED,OR DISCLOSED 10x46 port of Everett - Norton ExpansionM� INDUSTRIES INC.TO OTHERS EXCEPT AS AUTHORIZED BY THE . . wdmm Drawn By: LDG �DATE REVISION WRITTEN PERMISSION OF BLAZER INDUSTRIES. �� sasolneyst. ■ Aumsyfflc,OR97325-0489 WA Pacific Mobile Everett,WA Issue Date: 12-8-21 <br />