2000 TOWER ST 2024 BASE FILE 2025-10-24
>
Address Records
>
TOWER ST
>
2000
>
BASE FILE
>
2000 TOWER ST 2024 BASE FILE 2025-10-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2025 10:34:11 AM
Creation date
10/15/2025 3:26:03 PM
Metadata
Fields
Template:
Address Document
Street Name
TOWER ST
Street Number
2000
Tenant Name
BASE FILE
Year
2024
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL LELGENIGHT <br />POWER RECEPTACLES & OUTLETS <br />SERVICE GEAR - AS SHOWN ON PLANS <br />IXTURES&CONTROLS <br />ABBREVIATIONS <br />16 <br />SINGLE RECEPTACLE <br />i <br />CIRCUIT BREAKER PANELBOARD <br />NOTE: LIGHTING FIXTURE SYMBOLS SHOW LENGTH, MOUNTING & <br />A (200A) (AFTER A NUMBER) = AMPS <br />(@ <br />DUPLEX RECEPTACLE <br />r <br />LOAD CENTER <br />EMERGENCY EGRESS INFORMATION ONLY. REFER TO FIXTURE <br />DESIGNATIONS & LIGHTING FIXTURE SCHEDULE FOR WAP TYPE & <br />AF(200AF) (AFTER A NUMBER) = FUSE SIZE IN AMPS <br />f® <br />DOUBLE DUPLEX RECEPTACLE <br />G <br />LIGHTING CONTROL PANEL <br />OTHER FIXTURE SPECIFICS. <br />AFF <br />ABOVE FINISHED FLOOR <br />(9 <br />DUPLEX GFCI RECEPTACLE <br />G <br />EXISTING PANELBOARD TO REMAIN <br />0 SURFACE CEILING MOUNTED DOWNUGHT <br />AHJ <br />AUTHORITY HAVING JURISDICTION <br />I® <br />DOUBLE DUPLEX GFCI RECEPTACLE <br />o <br />TERMINAL CABINET <br />O RECESSED DOWNUGHT (ROUND) <br />AL <br />ALUMINUM <br />4� <br />DUPLEX RECEPTACLE MOUNTED IN CEILING <br />0 <br />SWITCHBOARD OR MOTOR CONTROL CENTER, SIZE AS <br />❑D RECESSED DOWNUGHT (SQUARE) <br />ATS <br />AUTOMATIC TRANSFER SWITCH <br />DOUBLE DUPLEX RECEPTACLE MOUNTED IN CEILING <br />SHOWN ON PLANS <br />BKR <br />BREAKER <br />F—T] <br />DRY TYPE TRANSFORMER (SEE NOTES & RISER DIAGRAM <br />❑ 0 PENDANT MOUNTED FIXTURE OR CHANDELIER <br />C <br />CONDUIT <br />t® <br />DUPLEX RECEPTACLE MOUNTED +4"O.C. ABOVE COUNTER OR <br />FOR SIZE) <br />4 Q SINGLE POINT SOURCE WALL MOUNTED FIXTURE <br />CKT <br />CIRCUIT <br />BACKSPLASH, WHEN PRESENT (U.O.N.) <br />DOUBLE DUPLEX RECEPTACLE MOUNTED +4°O.C. ABOVE <br />® <br />TRANSFER SWITCH <br />La WALL SCONCE <br />CL <br />CENTERUNE <br />COUNTER OR BACKSPLASH, WHEN PRESENT (U.O.N.) <br />F-O WALL MOUNTED LONG ARM FIXTURE <br />CLG <br />CEILING <br />10 <br />DUPLEX GFCI RECEPTACLE MOUNTED +4°O.C. ABOVE COUNTER <br />UTILITY TRANSFORMER <br />® SURFACE MOUNTED LINEAR FIXTURE <br />C.O. <br />CONDUIT ONLY <br />OR BACKSPLASH, WHEN PRESENT (U.O.N.) <br />® RECESSED LINEAR FIXTURE <br />CRP <br />CONTROL RELAY PANEL <br />f® <br />DOUBLE DUPLEX GFCI RECEPTACLE MOUNTED +4"O.C. ABOVE <br />METER <br />PENDANT MOUNTED LINEAR FIXTURE <br />CU <br />COPPER <br />COUNTER OR BACKSPLASH, WHEN PRESENT (U.O.N.) <br />GROUND BAR <br />E7= SURFACE MOUNTED LINEAR FIXTURE (NARROW BODY) <br />(D) <br />DEMOLISH <br />*WP <br />GFCI RECEPTACLE WITH WEATHERPROOF WHILE —IN —USE COVER <br />O <br />WEATHERHEAD (PLAN VIEW) <br />COI LINEAR STRIP FIXTURE <br />DIA <br />DIAMETER <br />0 <br />DUPLEX RECEPTACLE MOUNTED ON WIREMOLD <br />PPO <br />UTILITY POWER POLE (SITE PLAN) <br />LINEAR INDUSTRIAL STRIP FIXTURE <br />DISC <br />DISCONNECT <br />WALL MOUNTED LINEAR FIXTURE <br />DISP <br />DISPOSER <br />j® <br />DOUBLE DUPLEX RECEPTACLE MOUNTED ON WIREMOLD <br />® <br />GROUND ROD LOCATION <br />OF <br />DRINKING FOUNTAIN <br />[0 <br />DUPLEX RECEPTACLE MOUNTED HORIZONTALLY <br />0 <br />HANDHOLE OR PULLBOX (SITE PLAN) <br />WALL MOUNTED STRIP FIXTURE <br />� WALL MOUNTED INDUSTRIAL LINEAR FIXTURE <br />DW <br />DISHWASHER <br />FLUSH FLOOR OUTLET BOX WITH DEVICES SHOWN <br />CONDUITS <br />AND CIRCUITING <br />� RECESSED LINEAR WALLWASHER <br />E.C. <br />ELECTRICAL CONTRACTOR <br />60 i <br />FLOOR POKE-THRU WITH DEVICES SHOWN <br />WIRING CONCEALED IN CEILING OR WALL <br />LINEAR UNDERCOUNTER FIXTURE <br />ECB <br />(E) <br />ENCLOSED CIRCUIT BREAKER <br />EXISTING TO REMAIN <br />LED COVE OR UNDER COUNTER LIGHT (LENGTH AS SHOWN <br />Or <br />POWER POLE WITH DEVICES SHOWN <br />---- <br />WIRING CONCEALED UNDER FLOOR OR UNDERGROUND <br />ID ON PLAN, TRANSFORMER(S) SHOWN AS REQUIRED) <br />EMT <br />ELECTRICAL METALLIC TUBING <br />/—� CONDUIT HOME -RUN <br />vim^ TRACK LIGHT (LENGTH AS SHOWN ON PLAN) <br />EXTG <br />EXISTING (USED AS ABBREVIATION IN TEXT) <br />19 <br />DUPLEX RECEPTACLE WITH 1/2 SWITCHED <br />EV <br />ELECTRIC VEHICLE (CHARGER) <br />CONDUCTORS CONDUIT <br />a RECESSED WALLWASHER <br />f® <br />DOUBLE DUPLEX RECEPTACLE WITH 1/2 SWITCHED <br />C <br />PHASE CONDUCTOR(S) <br />FAAP <br />FIRE ALARM ANNUNCIATOR PANEL <br />NEUTRAL CONDUCTOR <br />y FLOODLIGHT OR MONOPOINT <br />FACP <br />FIRE ALARM CONTROL PANEL <br />I®T <br />TAMPER RESISTANT RECEPTACLE <br />GROUND CONDUCTOR <br />® SURFACE LINEAR EMERGENCY EGRESS FIXTURE <br />FUR <br />FLOOR <br />9 <br />SINGLE SPECIAL PURPOSE RECEPTACLE <br />F GROUND WIRE <br />® RECESSED UNEAR EMERGENCY EGRESS FIXTURE <br />F.O.I.C. <br />FURNISHED BY OTHERS, INSTALLED <br />0 <br />JUNCTION BOX WITH BLANK COVER <br />" CONDUIT BENDS TO CHANGE ELEVATION AT THIS POINT <br />2'x4' FIXTURE SPLIT BETWEEN NORMAL &EMERGENCY <br />BY ELECTRICAL CONTRACTOR <br />ie <br />FURNITURE SYSTEM POWER FEED. CONNECT CONDUCTORS <br />CONDUIT STUB -UP <br />® EGRESS WITH UL924 RELAY. DUAL CIRCUITS SHOWN ON <br />FSD <br />FIRE SMOKE DAMPER <br />TO FURNITURE SYSTEM FLEX CONDUIT PROVIDED BY <br />H-3/X-23 PLANS. <br />FUT <br />FUTURE <br />OTHERS. VERIFY REQUIREMENTS. <br />- 4 3-- CONDUIT BREAK <br />❑r. * RECESSED EMERGENCY EGRESS DOWNUGHT <br />GEN <br />GENERATOR <br />IGi <br />CLOCK OUTLET (RECESSED 120V RECEPTACLE) <br />CONDUIT CONTINUES ELSEWHERE (NOTED ON PLAN) <br />GFCI <br />GROUND FAULT CIRCUIT INTERRUPTER <br />KD <br />DOORBELL <br />S- *-* <br />CONDUIT TO BE REMOVED <br />SURFACE EMERGENCY EGRESS DOWNUGHT <br />T FLOODLIGHT, MONOPOINT OR TRACK HEAD EGRESS <br />GND <br />GROUND <br />CABLE TRAY <br />HH <br />HANDHOLE <br />TELE/COMMUNICATIONS SYSTEM DEVICES <br />f 04W," EGRESS COVE LIGHT OR STRIP <br />HTR <br />HEATER <br />�•—•— MULTI -OUTLET ASSEMBLY (SEE NOTES ON PLAN) <br />TELEPHONE <br />MIUNNERSAL/CEILING MOUNTED EXIT SIGN <br />HWT <br />HOT WATER TANK <br />/W <br />WALL MOUNTED TELEPHONE (VERIFY MOUNTING HEIGHT) <br />CONDUIT WITH BELL END <br />WALL MOUNTED EXIT SIGN <br />HOA <br />HAND -OFF -AUTO <br />Q <br />SINGLE GANG TELEPHONE/DATA OPENING <br />EQUIPMENT CONNECTIONS & CONTROLS <br />® ® DIRECTIONAL EXIT SIGN (ARROWS INDICATE ONE OR <br />kCMIL <br />THOUSANDS OF CIRCULAR MILS <br />d WAP <br />WIRELESS ACCESS POINT <br />TWO SIDES AND DIRECTION INDICATED) <br />KVA <br />1000 VOLT AMPERES <br />® <br />EQUIPMENT CONNECTION <br />� EMERGENCY EXIT SIGN WITH DUAL PATHWAY HEADS <br />KW <br />1000 WATTS <br />� <br />JUNCTION BOX &CONDUIT FOR FURNITURE SYSTEM <br />TELE/DATA CONNECTIONS <br />10 <br />WALL MOUNTED EQUIPMENT CONNECTION <br />t1' DUAL HEAD EMERGENCY EGRESS FIXTURE <br />LCP <br />UGHTING CONTROL PANEL <br />a2 <br />DATA/COMM OUTLET (NUMBER INDICATES NUMBER OF JACKS. 'B' <br />4 <br />MOTOR CONNECTION <br />o-� ARM MOUNTED POLE LIGHT (ON SITE PLAN) <br />LT <br />LIGHT <br />INDICATES BLANK PLATE) <br />95 <br />FAN CONNECTION <br />0+❑ DUAL HEADED ARM MOUNTED POLE LIGHT (ON SITE PLAN) <br />LTS(LTG) <br />LIGHTS (LIGHTING) <br />ITS <br />TELEPHONE TERMINAL BOARD - 3/4" FIRE RESISTANT <br />jp <br />ELECTRIC WALL HEATER CONTROLLED BY WALL. <br />POST TOP AREA LIGHT <br />LV <br />LOW VOLTAGE <br />PLYWOOD, 8' HIGH x LENGTH SHOWN ON PLAN <br />1J-"' <br />MOUNTED THERMOSTAT <br />MCB <br />MAIN CIRCUIT BREAKER <br />®319"x19" <br />TWO -POST FLOOR MOUNTED DATA <br />FO <br />ELECTRIC WALL HEATER WITH INTEGRAL THERMOSTAT <br />RECESSED STEP UGHT <br />MECH <br />MECHANICAL <br />EQUIPMENT RACK <br />8 RECESSED DIRECT BURIAL FLOODLIGHT <br />MH <br />MANHOLE <br />® <br />±18-x20- WALL MOUNTED DATA EQUIPMENT RACK <br />N--N <br />ELECTRIC UNIT HEATER <br />ARM WALL MOUNTED DOCK LIGHT <br />MLO <br />MAIN LUGS ONLY <br />❑I <br />DISCONNECT SWITCH <br />MSC <br />MULTI -SCENE CONTROLLER <br />AUDIOVISUAL DEVICES <br />aF 1 <br />FUSED DISCONNECT SWITCH <br />S SINGLE POLE LIGHT SWITCH <br />MW <br />MICROWAVE <br />S' THREE POLE LIGHT SWITCH <br />N3R <br />NEMA 3R <br />I] <br />AUDIOVISUAL OURET (SEE DRAWING NOTES FOR TYPE) <br />® <br />MAGNETIC MOTOR STARTER <br />NIC <br />NOT IN CONTRACT <br />❑A <br />AUDIO AUXILLIARY INPUT <br />COMBINATION STARTER AND DISCONNECT <br />S' FOUR POLE LIGHT SWITCH <br />So DIMMER SWITCH <br />NREC <br />NON-RESIDENTIAL ENERGY CODE <br />® <br />ASSISTED LISTENING DEVICE <br />B <br />ENCLOSED CIRCUIT BREAKER <br />Sos OCCUPANCY SENSOR LIGHT SWITCH <br />OC <br />ON CENTER <br />IR <br />INFRARED RECEIVER FOR WIRELESS MICROPHONE SYSTEM <br />® <br />VARIABLE FREQUENCY DRIVE <br />SyS VACANCY SENSOR LIGHT SWITCH <br />OH <br />OVERHEAD <br />❑M <br />MICROPHONE JACK <br />O <br />HAND/OFF/AUTO SWITCH <br />Su, LOW VOLTAGE SWITCH CONTROLLED BY ROOM SENSOR <br />OS <br />OCCUPANCY SENSOR <br />® <br />0 <br />START -STOP PUSHBUTTON SWITCH <br />LIGHT SWITCH SUBSCRIPTS ARE AS FOLLOWS: <br />PC <br />PHOTOCELL <br />MICROPHONE/AUXIUARY JACK COMBINATION PLATE <br />0 <br />PUSHBUTTON SWITCH <br />SLyO <br />bxr LV VOLTAGE, D <br />® <br />REMOTE VOLUME CONTROLLER <br />S" <br />MOTOR RATED SWITCH <br />=LOW =DIMMING <br />L LOWER LEITER PONDS TO LETTER AT <br />PNL <br />PN <br />PANELBOARD <br />POST INDICATOR VALVE <br />FIXTURES TOE CONTRCORROLLED <br />S❑ <br />CEILING MOUNTED SPEAKER <br />18 <br />WALL MOUNTED THERMOSTAT <br />Ri = RELAY III IN LIGHTING CONTROL PANEL <br />P.O.S. <br />POINT OF SALE <br />Ffl <br />WALL MOUNTED SPEAKER <br />t� <br />ELECTRIC BASEBOARD HEATER <br />= <br />So SENSOR ZONE <br />PP <br />POWER POLE/POWER PACK (SEE PLAN LOCATION) <br />❑TV <br />TELEVISION OUTLET <br />(LENGTH & WATTAGE ON PLAN) <br />® VACANCY SENSOR <br />PSE <br />PUGET SOUND ENERGY <br />® <br />FUTURE SMARTBOARD JUNCTION BOX - MOUNT ON WALL <br />® <br />HEAT LAMP <br />® OCCUPANCY SENSOR <br />PUD <br />PUBLIC UTILITY DISTRICT <br />BEHIND FUTURE EQUIPMENT AS DIRECTED ON PLANS. <br />® <br />EXHAUST FAN/HEAT LAMP COMBINATION <br />® PHOTOCELL LIGHT SENSOR <br />PV <br />PHOTOVOLTAIC <br />PROVIDE 3/4"C.O. TO ACCESSIBLE CEILING SPACE. <br />® <br />EXHAUST FAN/LIGHT COMBINATION <br />® COMBINATION VACANCY/PHOTOCELL SENSOR <br />REF <br />RECEPTACLE(S) <br />® <br />4-GANG SOUND SYSTEM INTERFACE PLATE <br />® SENSOR POWER PACK <br />REF <br />REFRIGERATOR <br />PADDLE FAN <br />0 PHOTOCELL AIMED NORTH, MOUNTED ON BUILDING EXTERIOR <br />(R) <br />RELOCATED EXISTING <br />NOTES <br />AND MISCELLANEOUS SYMBOLS <br />Sf UGHT SWITCH WITH PILOT UGHT <br />RQMTS <br />REQUIREMENTS <br />FLAGNOTE - IDENTIFIES A SPECIFIC ITEM ON A DRAWING. <br />Sx KEYED SWITCH <br />SCL <br />SEATTLE CITY UGHT <br />COORESPONDS TO A SCHEDULE IN THE ELECTRICAL SET <br />RE <br />THAT EXPLAINS DETAILS OR FEATURES OF THAT ITEM. <br />FIRE ALARM <br />SYSTEM EQUIPMENT <br />SNOPUD <br />SNOHOMISH PUBLIC UTILITY DISTRICT <br />INTERCOM/CLOCK SYSTEM DEVICES <br />IX_3 <br />MECHANICAL FLAG - DEFINES MECHANICAL EQUIPMENT AND <br />❑F <br />MANUAL PULL STATION <br />SO SPEAKER, CEILING MOUNTED <br />SPD <br />SURGE PROTECTIVE DEVICE <br />COORESPONDS TO DESIGNATIONS IN MECHANICAL PLANS AND <br />,IIRr, <br />IJ <br />WALL MOUNTED HORN STROBE ALARM <br />/ <br />5 SPEAKER, WALL MOUNTED <br />SQ <br />SQUARE <br />SCHEDULES. COORESPONDS TO MECHANICAL CONNECTION <br />SCHEDULE IN THE ELECTRICAL SEr. <br />K DIGITAL CLOCK COMBINATION OUTLET <br />SW <br />SWITCH <br />CEILING MOUNTED HORN/STROBE ALARM <br />TBD <br />TO BE DETERMINED <br />2W <br />EQUIPMENT FLAG - DEFINES SPECIAL (IE: COOKING) <br />LFI <br />WALL MOUNTED STROBE (ONLY) ALARM <br />ANALOG CLOCK OUTLET <br />� BELL, WALL MOUNTED <br />TTB <br />TELEPHONE TERMINAL BOARD <br />EQUIPMENT ON A PLAN AND COORESPONDS TO DESIGNATIONS <br />TYP <br />TYPICAL <br />IN AN EQUIPMENT SCHEDULE IN THE ELECTRICAL SEr. <br />F( <br />CEILING MOUNTED STROBE (ONLY) ALARM <br />K�)l SPEAKER, WALL MOUNTED, EXTERIOR <br />REVISION CLOUD AND FLAG -CLOUD SURROUNDS <br />® <br />SMOKE DETECTOR <br />pi VOLUME SWITCH <br />UC <br />UG <br />UNDER COUNTER <br />UNDERGROUND <br />INFORMATION THAT HAS BEEN REVISED. EIDENTIFIES <br />H <br />� <br />HEAT DETECTOR <br />CALL (PANIC) SWITCH <br />THE REVISION IN WHICH THE CHANGES WERERE MADE. <br />ILL <br />UNDERWRITER'S LABORATORY <br />1 <br />Q <br />DUCT SMOKE DETECTOR <br />SECURITY SYSTEM EQUIPMENT <br />U.O.N. <br />UNLESS OTHERWISE NOTED <br />O <br />DETAIL NUMBER -APPEARS IN FRONT OF A TITLE ON <br />UTIL <br />UTILITY <br />DRAWINGS WITH MORE THAN ONE ILLUSTRATION. <br />1 <br />SSP SECURITY SYSTEM PANEL <br />3 <br />IDENTIFICATION SYMBOL - CROSS REFERENCES INFORMATION <br />OM <br />7 <br />MAGNETIC DOOR HOLDER <br />TAMPER SWITCH <br />o <br />® CARD READER ACCESS OUTLET <br />VA <br />VFD <br />VOLT AMPERES <br />VARIABLE FREQUENCY DRIVE <br />El.l <br />IN ONE AREA WITH A DETAIL (TOP AND SHEET (BOTTOM III)O <br />xc KEYPAD <br />IN ANOTHER IN THE ELECTRICAL SEr. <br />NOTE: THESE STANDARDS APPLY ON ALL ELECTRICAL DRAWINGS <br />O <br />T� <br />FLOW SWITCH <br />BEAM SMOKE DETECTOR TRANSMITTER <br />Ed VIDEO ENTRY LIGHT <br />VS <br />W <br />VACANCY SENSOR <br />WATTS <br />UNLESS NOTED OTHERWISE. <br />BEAM SMOKE DETECTOR RECEIVER <br />CpO SECURITY CAMERA <br />WAP <br />WIRELESS ACCESS POINT <br />Q SYMBOLS SHOWN ON PLANS IN STANDARD (HEAVY) <br />OJ <br />FIRE/SMOKE DAMPER <br />IXIJ MULTI -DIRECTIONAL SECURITY CAMERA AS SHOWN <br />WC <br />WATER COOLER <br />(® <br />LINE WEIGHT ARE NEW OR RELOCATED WORK. <br />�o2S <br />W/D <br />WASHER/DRYER <br />10 SYMBOLS SHOWN IN LIGHT UNE WEIGHT OR <br />FRCP <br />o <br />FIRE ALARM CONTROL PANEL <br />W/0 <br />WITHOUT <br />f® <br />(E) DESIGNATED WITH (E) INDICATE EXISTING TO REMAIN. <br />WP <br />WEATHERPROOF <br />a F---T� <br />hpx SYMBOLS SHOWN AS DASHED INDICATE ITEMS TO <br />XFMR <br />TRANSFORMER <br />L---- <br />BE REMOVED OR DEMOLISHED. <br />fj10A1 <br />PSDRAWING <br />INDEXEO.1 <br />ELECTRICAL LEGEND AND SCHEDULES <br />ue & <br />E2.1 BASEMENT POWER FLOOR PLAN <br />1011 $W KLICKITAT WAY, STE. 208 <br />E9.1 ONE -LINE DIAGRAM AND PANEL SCHEDULES <br />SEATTLE, WA 98134 1 (206) 631-8442 <br />https://w .oalps.00m <br />PROJECT NOTES <br />&EVERETT <br />bk <br />1. COMPLY WITH 2O18 STATE COMMERCIAL ENERGY CODE. <br />COMPLY WITH <br />2. INSTALLATION SHALL COMPLY WITH 2O20 NATIONAL ELECTRIC CODE. <br />J <br />(PF <br />3. INSTALLATION SHALL COMPLY WITH 2O18 INTERNATIONAL BUILDING CODE. <br />4. INSTALLATION SHALL COMPLY WITH 2O18 INTERNATIONAL FIRE CODE. <br />ENGINEERING <br />5. PER WASHINGTON ADMINISTATIVE CODE 296-468-900.3.—A&D, <br />NO SERVICE OR FEEDER LOADS INCREASED BY MORE THAN 5% AND <br />LIGHTING DOES NOT EXCEED 277V TO GROUND. THEREFORE ELECTRICAL <br />Consulting Electrical Engineers <br />J J <br />PERMIT TO BE OVER THE COUNTER. <br />19515 North Creek Parkway, Suite 302 <br />Bothell, Washington 98011 <br />Phone: 425-402-9400 Fax: 425402-9402 <br />EL S c <br />SCOPE OF WORK <br />1. REPLACEMENT OF EXISTING 208V, 3-PHASE, 600 AMP DISTRIBUTION BOARD 'OLYMPUS'. EXISTING BOARD <br />IS OLD WESTINGHOUSE CONSTRUCTION AND 10K AID RATED AND AT THE END OF USABLE UFE. q 029I�024� <br />2. NO CHANGE IN LOAD. b• f <br />ORAL <br />LLr�J <br />li <br />0 <br />Q <br />W <br />0 <br />_ J <br />J <br />O <br />''w^^ <br />v <br />= <br />o <br />c� <br />U <br />� <br />LLJ <br />HW <br />C14 <br />W ~ 00 <br />N`Ua <br />G� <br />O <br />UW <br />a0 LU <br />w <br />O <br />a~LU <br />> <br />W <br />a <br />WO W <br />�O <br />a <br />~ <br />U <br />LU <br />W <br />\ <br />/ <br />\� <br />/ <br />W <br />LLJ <br />Rev. #: Revision: Dale: <br />DRAWN BY: REVIEWED BY: <br />TN MSC <br />PROJECTSTATUS: <br />PERMIT DRAWINGS <br />ISSUE DATE: <br />02/09/2024 <br />SHEET SIZE: <br />ARCH D (24" x 36") <br />DRAWING SCALE: <br />As indicated (U.N.O.) <br />SHEET NO. / TITLE: <br />E0.1 <br />ELECTRICAL LEGEND <br />AND SCHEDULES <br />PROJECT NUMBER: <br />