COMMENT/CORRECTION: <br /> 3. Provide information on existing furnace that indicates how current furnace meets current code <br /> (IRC 505) <br /> RESPONSE: New mini split added for the new conditioned space. Energy credit table is <br /> revised. See sheet A2 &A6. . <br /> COMMENT/CORRECTION: <br /> 4. Please show on the plans where the existing furnace exhaust exits the building, and that it is at <br /> least 10 feet away from any openings into the building(windows). <br /> RESPONSE: The existing furnace exhaust vent is located a few inches from the new window. <br /> It will be moved at a minimum of 10' from the window. See Sheet A6 — Proposed <br /> Main Floor Plan for revision. <br /> COMMENT/CORRECTION: <br /> 5. Furnace room on main floor. Please add a note indicating the interior of the room is completely <br /> sealed with %"gyp bd on walls and ceiling interior of closet. Provide fireblocking at penetrations <br /> (IRC 302.11) <br /> RESPONSE: Note is added on the plan <br /> Architectural <br /> COMMENT/CORRECTION: <br /> 1. Foam plastics should be protected and meet flame spread<75 and smoke development <br /> requirements<450. On detail 2/A4, please show%"gyp board concealing exposed R-5 insulation <br /> on curb. (IRC 316.3, IRC 316.4) <br /> RESPONSE: The detail is revised and the note is added. <br /> COMMENT/CORRECTION: <br /> 2. It appears that some of the existing windows in proposed bedrooms do not meet the sill height <br /> requirement of maximum 44"AFF. Please confirm and add notes to floor plans, or provide <br /> windows that comply. (IRC R310.2.3). <br /> RESPONSE: Window siil heights are shown in the plan. See sheet A6. <br /> COMMENT/CORRECTION: <br /> 3. Vapor retarders are required on interior side of frame wall in Climate Zone Marine 4, Please <br /> show in section accordingly(IRC 702.7). <br /> RESPONSE: Vapor retarder class II - kraft-faced fiberglass batts is show on the section. See <br /> sheet A3. <br /> COMMENT/CORRECTION: <br /> 4. Extents of weather barrier is not clear. Please clarify on the wall section 2/A4. (IRC 703.2) <br /> RESPONSE: Wall insulation for existing garage wall is identified. See detail 2/A4. <br /> COMMENT/CORRECTION: <br /> 5. Please add note indicating%"gypsum board on ceiling of converted garage. (IRC 302.13) <br /> RESPONSE: This note is added on Proposed Main Floor Plan, Proposed Roof plan and Building <br /> Section. // <br />
The URL can be used to link to this page
Your browser does not support the video tag.