Laserfiche WebLink
STORMWATER TREATMENT <br />AREA (TYP) <br />6" PERFORATED UNDERDRAIN (TYP) <br />DISTRIBUTION CHANNEL. <br />SEE STRUCTURAL <br />DRAWINGS S-40-1002 FOR <br />MORE DETAILS. <br />ENERGY DISSIPATION <br />STONE (TYP) <br />1 <br />D-40-3003 <br />2 <br />D-40-3003 <br />18" SW <br />40-FLT-0101 <br />40-FLT-0102 <br />40-G-0040 <br />40-G-0030 <br />40-G-0020 <br />40-G-0010 <br />1 <br />1 <br />2 <br />3 <br />4 4 4 4 4 4 <br />2 <br />5 5 2 <br />666 <br />2 <br />3 <br />444444 <br />2 <br />552 <br />6 6 6 <br />6" SW <br />8" D <br />7 <br />7 <br />7 <br />7 <br />7 <br />7 <br />FROM DIVERSION <br />STRUCTURE. SEE <br />DRAWING D-40-1001 <br />8 <br />8 <br />EALNIO N GTR <br />SRFOE <br />SPSTA EREERSGEITE G ID NTNOE <br />HOFWAS <br />N <br />I <br />57595M YOLL Y E. <br />B <br />R <br />APLANS ISSUED FOR <br />BID <br />ACTION DATE APRVD ACTION DATE APRVD ACTION DATE APRVD <br />CONST RECORD <br />Drawing <br />Sheet No. <br />Of Total <br />Designed <br />Drawn <br />Checked <br />Design Review Level <br />500 <br />Plot dateFilepath\FilenameWO# UP-3525 <br />PORT GARDNER <br />everettwa.gov <br />3200 Cedar Street <br />Everett, WA 98201 <br />425.257.8800 <br />NO. DATE APRVD REVISION <br />12/2/2024 ZB <br />STORAGE FACILITY - <br />FACILITY CONSTRUCTION PACKAGE <br />09/03/2025 ZBAutodesk Docs://157889 - PGSF/D-3525-40V23.rvt8/26/2025 10:53:02 AMD-40-1004 <br />349 <br />PROCESS <br />STORMWATER TREATMENT STRUCTURE <br />UPPER PLAN <br />J. FU <br />T. LEMON <br />M. BRAY <br />SCALE: 3/16" = 1'-0" <br />STORMWATER TREATMENT STRUCTURE UPPER PLAN <br />GENERAL NOTES: <br />1. SUBMIT VACTOR PIPING PRODUCT DATA, LAYOUT, AND <br />INSTALLATION DRAWINGS PER SECTION 40 05 01. <br />SUPPORT VACTOR PIPING PER SECTION 40 05 07. <br />KEYNOTES: <br />1 8" EMERGENCY OVERFLOW. <br />2 8" X 90 DEGREE ASTM B221 SCHEDULE 40 ALUMINUM <br />SHORT SUCTION ELBOW WITH FLAT FLANGES ON EACH <br />END. <br />3 8" ASTM B221 SCHEDULE 40 FLANGED ELBOW WITH FLAT <br />FLANGE ON ONE END AND 8" FEMALE BANDLOCK WITH <br />GASKET. <br />4 VACTOR PIPING: 8" X 12' ASTM B221 SCHEDULE 40 <br />ALUMINUM PIPE WITH ALUMINUM FLANGES ON EACH END. <br />5 8" ASTM B221 SCHEDULE 40 ALUMINUM FLANGED TEE <br />WITH FLAT FLANGES ON EACH END AND 8" FEMALE <br />BANDLOCK WITH GASKET. <br />6 8" X 5' ASTM B221 SCHEDULE 40 ALUMINUM PIPE WITH <br />FLANGE ON ONE END AND 8" FEMALE BANDLOCK WITH <br />GASKET. <br />7 TREATMENT MEDIA AND UNDER DRAIN PIPING TO BE <br />INSTALLED UNDER A SEPARATE CONTRACT. <br />8 MEDIA AND UNDERDRAIN FOR 40-FLT-0101 AND <br />40-FLT-0202 FURNISHED AS PART OF VENDOR PACKAGE <br />SPECIFIED WITH SECTION 33 46 59.