Subject / Project Title
Port Gardner Storage Facility – Facility Construction Package Addenda
Tracking Number
0005035
Total Compensation
$0.00
Contract Type
Capital Contract
Contract Subtype
Capital Construction Contracts and Change Orders
Retention Period
10 Years Then Transfer to State Archivist
Imported from EPIC
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
Port Gardner Storage Facility Volume 7 Attachment O <br /> Page 34 <br />CITY OF EVERETT ⋅ 3200 Cedar Street ⋅ Everett, WA 98201 ⋅ (425) 257-8800 ⋅ Fax (425) 257-8882 <br /> <br />Q185 - Please specify if the screen manufacture will need supply a PE stamp for the <br />certified hydraulic head loss calculations and frame and screen structural calculations <br />under 46 21 13, 1.05, A., 8., or any other portions of the project. <br />The calculations must be signed by the furnishing Manufacturer, but do not <br />require a PE stamp. Refer to the specifications for calculations requiring a PE <br />stamp. <br />Q186 - Please specify if the screen manufacture will need to provide any bid bond, <br />payment bonds, performance bonds, etc. <br />Contractor requirements for bonding is described the Contract Documents. <br />Q187 - Regardless of whether or not the Owner or the Contractor is responsible for <br />third-party testing required in spec section 030100, we assume these costs will fall <br />under Bid Item #30, Allowance for Concrete Repairs (Force Account). Please confirm. <br />Third party testing will be completed by the Owner's Representative who will bear <br />the costs under a separate contract. <br />Q188 - PVC Conduit Bends Concrete Encased Is the purpose of the spec to include <br />PVC coated conduit elbows in the duct back less than 90 degrees? Section 26 05 03 <br />3.02 asks for 90 degree elbows emerging from the earth or concrete duct bank to be <br />PVC coated so I’m assuming that PVC schedule 40 45 degree elbows would be <br />acceptable If encased in concrete. <br />Section 26 05 33-3.02.B.2.q is specific to requirements for conduit stub-ups <br />emerging from concrete/masonry/earth. The 90-degree elbow that emerges needs <br />to be PVC-coated rigid steel conduit. For conduits that remain fully encased in <br />concrete ductbank (not emerging), PVC Schedule 40 raceway and fittings are <br />permitted. <br />Q189- Please provide specifications for the davit bases per sheet 248. <br />Davit bases shall be provided for fall protection per 05 50 00. <br />Q190 - Where does detail C/CD-10-7005 apply? <br />This detail applies at the locations indicated in Exhibit A of Specification 40 05 <br />07.14. See Keynote 24. <br />Q191 - Drawing 332 makes it look like the 30” CS between CSVT 30-01 and the <br />flushing sump is new. Drawing 119 shows it as existing. Please clarify if new or existing. <br />The 30" CS between CSVT 30-01 and the flushing sump is new. The pipe is not <br />shown on Sheet No. 119, but is shown as new on Drawing C-10-1303.
The URL can be used to link to this page
Your browser does not support the video tag.