3003 W CASINO RD 2024 BLDG 40-26 Plans 2026-01-02 (3)
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-26
>
Plans
>
3003 W CASINO RD 2024 BLDG 40-26 Plans 2026-01-02 (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2026 12:03:14 PM
Creation date
1/2/2026 12:00:02 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-26
Permit
M2407-044
Year
2024
Notes
Waste Water System and Process Water System Tank Cleanout
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
74
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEGEND GENERAL NOTES <br /> X HYDRAULIC PIPE ANCHOR 1. SEE 40-026-MOI FOR PIPING SPECIFICATIONS <br /> HYDRAULIC PIPE GUIDE <br /> B HYDRAULIC LOW POINT DRAIN 2�1" REDUCED-PRESSURE BACKFLOW PREVENTER <br /> �a HYDRAULIC RETURN SINGLE BLOCK AND BLEED WATTS: 909 <br /> VALVE CONFIGURATION <br /> po--pd HYDRAULIC SUPPLY DOUBLE BLOCK AND BLEED Lj->4" BUTTERFLY VALVE: DEMCO 22122-5114351 <br /> T <br /> 3.5 4 45 VALVE CONFIGURATION ] <br /> PIPE SUPPORT 4. IN ALL TUNNELS, UTILIDORS, AND TRENCHES WITH <br /> HYDRAULIC PIPING (EXCEPT PEDESTRIAN TUNNELS), <br /> PROVIDE THE FOLLOWING FLOOR COATING: <br /> NEOGARD 70714/70715 CHEMICAL RESISTANT <br /> PRIMER: 2 COMPONENT 100% SOLIDS EPDXY RESIN <br /> CYCOALIPHATIC <br /> 1"PPCW UP <br /> N OGARD707 A HARDENER,14/ 0715100% SOLIDSEPDXY (LP) <br /> COATING FINISH. <br /> MATCH LINE 2" HYDRAULIC SUPPLY 5�SEE STRUCTURAL DRAWING S665, DETAIL 10 FOR <br /> UGM121 M466 3 5 4" HYDRAULIC RETURN GUIDES. <br /> -- -- -- -- -- -- -- -- -- <br /> SEE DWG UGM116 PIPE RUNNING 18" <br /> 3 3" SAN � ©SEE STRUCTURAL DRAWING 5665, DETAIL 1 FOR <br /> UGM121 M584I AFF, 6" OFF WALL ANCHORS. <br /> VALVE NUMBER: <br /> 5 a 40-26-S-X 11 FOR HYDRAULIC SUPPLY DOUBLE BLOCK AND BLEED <br /> D UGM121 M547 35 3 2 1 1/2" SAN UP I C VALVE ASSEMBLY, SEE DETAIL 3/M5XX. FOR <br /> 2" PSAN HYDRAULIC SUPPLY AN UGM121 UGM501 HYDRAULIC RETURN SINGLE BLOCK AND BLEED VALVE <br /> 89B 5 RETURN UP TO FD #8 ASSEMBLY, SEE DETAIL 4/M5XX. <br /> VERTICAL EXPANSION <br /> SP LOOP 8'x4'x8' ®FOR HYDRAULIC BERM CONTAINMENT DETAIL, SEE <br /> 89A 2" PSAN D STRUCTURAL DRAWING 5/S305. <br /> o <br /> w SEE STRUCTURAL DRAWING 5665, DETAIL 8 FOR <br /> ° vw HYDRAULIC PIPE SUPPORTS. <br /> - -----------5 <br /> 14 VALVE NUMBER: 40-26-R-X<a 10 SEE STRUCTURAL DRAWING S665, DETAIL 9 FOR <br /> VALVE NUMBER: 40-26-R-X <br /> 10 HEAVY DUTY HYDRAULIC PIPE SUPPORTS. <br /> I I 16 12 <br /> 5 ^ 11 BVHS20FH2242JA2UZZD, SAE C62 4-BOLT FLG, 316 <br /> - ---------------- - SPINDLE, PEEK SEALS STAINLESS BODY, 316 BALL <br /> VERTICAL EXPANSION LOOT 8'x4'x8' / <br /> 10 BUSHINGS AND WASHERS, EPR 0-RING, W/SR <br /> I ACTUATOR. BI-TORQ, PN-145-SR SPRING W/CAB <br /> a 15 VALVE NUMBER: 40-26-S-X <a LIMIT SWITCHES AND NAMUR SOLENOID. 1080 IN-LB. <br /> SP SUMP WITH PUMP - ---------------- - 14 VALVE NUMBER: 40-26-R-X 2 <br /> 74 30"4 X 4' DE ;,o 12 SEE DRAWING 40-26-MXXX, DETAIL X FOR SPRAY <br /> SEE DETAIL A 13 VALVE NUMBER: 40-26-S-X 2 SHIELD. <br /> UGM121UGM506 I <br /> 5 1 13 SEE 1/M605-11 FOR HYDRAULIC SUPPLY LOW POINT <br /> 1 DRAIN DETAIL. <br /> I� 14 SEE 2/M605-11 FOR HYDRAULIC RETURN LOW POINT <br /> B 7 VALVE ASSEMBLY: 40-26-S-X 0 DRAIN DETAIL. <br /> ROUTE ABOVE <br /> ZIP 4" SAN UP AND ELECTRIC TRAY UGM121UGM502 - --------------- 1 <br /> _ 1 15 SEE 2/M59X FOR HYDRAULIC SUPPLY HIGH POINT <br /> I� SYSTEM POC TO TRAILER 7 VALVE ASSEMBLY: 40-26-R-X (2' BELOW CEILING) VENT DETAIL. <br /> o BACKWATER VALVE - 5 <br /> w J.R. SMITH FIGURE 7012 M 2�GN7501 <br /> 1" CW UP OR OTHER APPROVED. 1 1/2" AIR LINE WITH BALL SUPPLY PIPE DN 4" UP 88" 15'-4 1/2" 6 SEE 3/M59X FOR HYDRAULIC RETURN HIGH POINT <br /> VALVE UP TO 1ST FLOOR. — 5 PIPE RUNNING 2' BELOW <br /> 2T OFF WALL DN 1' — ---_--- --- 8 6 VENT DETAIL. <br /> FII 2 HPIPFS 6" <br /> 40�-026�-�N�.9-0p L..0 40-026-N.9-0 .2 5 BELOW CEILING — CEILING, 6" OFF WALL <br /> CO SLOPE 1% g 6 4" HYDRAULIC RETURN <br /> — D <br /> 4" HYDRAULIC RETURN 4" A 4" SAN 6" DEEP 'RUNNING' TRAP 1" CW 6 4" SAN 5 7/8" 1 UGM121 UGM501 <br /> 1 IE 98'-0' 4"A 18'-0" 6'-0' IE 96'-10" 6" PSAN 2" HYDRAULIC SUPPLY CONSTRUCTION NOTES <br /> PIPE RUNNING 2'-8" BELOW PIPE RUNNING 2'-8" I I D <br /> CEILING, 6" OFF WALL BELOW CEILING, 6" RETURN PIPE - -------------- - � VALVE ASSEMBLY: 40-26-R-2`� � ROUTE PSAN TO LIFT STATION SE-6. <br /> OFF WALL 6" OFF WALL <br /> Iq <br /> VALVE ASSEMBLY: 40-26-S-2 a 2� PROVIDE 1 1/2" SAN UP THROUGH SLAB. <br /> 1 --------------- PROVIDE PPCW PIPE UP THROUGH SLAB. <br /> I � � 1 <br /> - ---------------- - 1' CW 1 <br /> 3/4" A <br /> 3 5 7 9 11 <br /> I 2" 4" 2" PSAN os Qn' <br /> ---------- ----- 6" PSAN 1 ----- ,----B - —i 25 J t <br /> IE 96'-5' 1 1 I�GM11OUGM1110GM1121UGM11-*GM114' <br /> MATCH LINE <br /> -- -- -- -- -- -- -- - -- -- -- -- - -- -- -- --- ---- - -I- - N.3 I <br /> SEE DWG UGM126 UGM1171UGM118UGM11d� o <br /> �JGM1 I�UGM <br /> I P I�1GM12aUMM21PGMI 221 GM I23PGMI24 N7 J----- <br /> IJGM125UGM1261JGM127!GM128�JGM12 m <br /> _ R <br /> I I I I I I <br /> BLDG 40-27 <br /> PARTIAL UNDERGROUND PLAN N KEY PLAN N <br /> SCALE:1/8"=1'-0" FIN. FLR. ELEV. 92'-0° SCALE: NONE <br /> F#MEERS ISSUED FOR CONSTRUCTION8' 4' 0 4' 8' 16' <br /> PROFESSIONAL STAMP & SIGNATURE <br /> APPLIES TO WORK WITHIN THE CLOUDED Seattle//Spokane//Baltimore DESIGN BY FSi DATE 03.14.24 SCALE: 1/8" <br /> REVISION AREAS ONLY AS INDICATED <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY DRAWN D?TE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> RECORD DRAWING ISSUED TO OWNER MGM DJH 06.30.94 E 737 NORTH LINE - HYDRAULICS W8861360 FSi KMC 01.25.24 �. <br /> "qo THIS DESIGN AND,oR C1E11ED PARTIAL PLUMBING PLAN-TUNNELS W8861360 D 03.14.24 <br /> �ti*` "�' � SPECIFICATION IS APPROVED SrleEr N <br /> A COLD WATER PIPING DEACTIVATED MJP CFH 09.11.98BOE//VG® W ENGINEER TITLE 737 NORTH LINE - 40-26 WING TANK CLEANOUT U G M 121 <br /> S APPROVED BY DEPT. DATE <br /> B 787 FA RECORD SET 555886 WH T MENIKET7I 06.22.07 e CHECRED <br /> N FSi �`� APPROVED BUILDING 40-026 JOB N0, COMP N0. <br /> C 5X5 RATE READINESS - RECORD SET 13884121 WH SAG 05.16.14 SS/ONAL EpG <br /> D 737 NORTH LINE-40-26 WING TANK CLEANOUT W8861360 FSi I KMC 1 03.14.24 APPROVED MECHANICAL MASTER COLN.7-P/3-5 EVERETT, WA DWG NG. 40-026-UGM121 <br />
The URL can be used to link to this page