Laserfiche WebLink
PGSF WMVD Storm and Combined Sewer - Construction Package 2 Grouting <br />Project No. 180162 03 60 00 - 6 <br /> <br />3.04 ADHESIVE FOR GROUTING REINFORCING BAR DOWELS <br />A. Follow manufacturer’s instructions. <br />3.05 CONCRETE REPAIR MORTAR <br />A. Concrete repair materials and procedures shall be submitted for review to the Owner’s <br />Representative and shall be accepted prior to commencement of the repair work. <br />B. Follow all manufacturer's instructions, including those for minimum and maximum <br />application thickness, surface preparation and curing. Add aggregate as required per <br />manufacturer's recommendations. Any deviations from the manufacturer's instructions <br />shall be submitted for review to the Owner’s Representative and shall be accepted prior <br />to commencement of the work. <br />3.06 CEMENT GROUT <br />A. Cement grout shall be used for grout toppings less than four inches thick and for <br />patching of fresh concrete. <br />B. Grouting shall comply with temperature and weather limitations in Section 03 30 00, <br />Cast-In-Place Concrete. <br />C. Cure grout in accordance with grout manufacturer’s instructions for prepackaged grout <br />and Section 03 30 00, Cast-In-Place Concrete, for non-prepackaged cement grout. <br />END OF SECTION