Laserfiche WebLink
PLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPL102 <br />111 <br />406 <br />29051900201500 <br />UNKNOWN <br />29051900200900 <br />UNKNOWN 29051900201100 UNKNOWNEASEMENT AFN 201907310975XX <br />XXXXXXXXXXXXXXXXXXXXXXXXXXXSAWCT SAWCT SAWCT <br />TCETCETCETCETCETCETCETCETCETCETCETCETCETCE <br />SAWCT SAWCT SAWCT SAWCT <br />SAWCT <br />SAWCT <br />SAWCT <br />EX 32" HDPE DWO <br />EX FENCE <br />SNOPUD 15 KV POWER DUCT <br />BANK (PROTECT IN PLACE)13 <br />11.5'± <br />A <br />- <br />5 <br />67 <br />4 <br />1 <br />12 <br />3 <br />9 <br />10 <br />2 <br />1 <br />BNSF ROWPORT OF EVERETT <br />NORTON TERMINAL <br />LIMIT OF EXISTING CITY <br />UTILITY EASEMENT <br />C <br />- <br />B <br />- <br />BNSF ROW <br />TEMPORARY CONSTRUCTION <br />EASEMENT. SEE G-2014. <br />EX FENCE14 <br />11 <br />SNOPUD TRANSMISSION POLES AND <br />ANCHORS SEE GENERAL NOTE 2. <br />TCE AREA 2 <br />TCE AREA 3 <br />PE AREA 4 <br />PE AREA 5 <br />EXISTING CURB <br />AND MEDIAN <br />4 <br />?Surveyed By # Date # Control Monument # City of Everett Field Book/Starting Page # / ###Filepath\FilenameC:\USERS\TFRANKLIN\DC\ACCDOCS\BC ACC PROJECT HUB\103977 - EVERETT CONVEYANCE PACKAGES A_C_E\PROJECT FILES\300 DESIGN\UP3815-02\CAD\XXX DEMO\SHEETS\CX-2002.DWGPlot date 12/8/2025 9:06 AM Plotted by Travis Franklin Last saved by TFranklin Plot style Everett-2016.stb Sheetset Name ####################### <br />DEMOLITION <br />NORTON TERMINAL <br />EXISTING IMPROVEMENTS DEMOLITION - 2 <br />CX-2002 <br />12 <br />R. DAVIES, P. VENC <br />T. FRANKLIN <br />R. DAVIES <br />Designed <br />ACTION APRVDDATE <br />Drawn <br />Checked <br />REVISIONDATENO.APRVD <br />PLANS ISSUED FOR 3200 Cedar Street <br />Everett, WA 98201 <br />425.257.8800 everettwa.gov <br />PORT GARDNER STORAGE FACILITY <br />WEST MARINE VIEW DRIVE <br />STORM AND COMBINED SEWER DESIGN <br />WORK ORDER UP3815-02 <br />ACTION APRVDDATE ACTION APRVDDATE <br />BID CONST <br />Design Review Level <br />142RECORD <br />Of Total <br />Sheet No. <br />Drawing <br />PRELIMINARY44572 <br /> <br />Know what's below. <br />before you dig.Call <br />R <br />GENERAL NOTES <br />KEY NOTES <br />1.THE EXISTING UNDERGROUND UTILITIES SHOWN <br />HEREIN ARE APPROXIMATE LOCATIONS ONLY BASED <br />ON THE FIELD LOCATION OF UTILITY LOCATE PAINT <br />MARKS AND PHYSICAL FEATURES VISIBLE ON OR <br />ABOVE THE GROUND SURFACE. THE CONTRACTOR <br />SHALL DETERMINE THE LOCATION OF ANY AND ALL <br />UNDERGROUND UTILITIES BEFORE BEGINNING WORK. <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY <br />AND ALL DAMAGES ARISING OUT OF THEIR FAILURE TO <br />EXACTLY LOCATE AND PROTECT ALL EXISTING UTILITY <br />FACILITIES. <br />2.WORK AROUND POWER AND GAS UTILITIES MUST BE <br />PERFORMED IN ACCORDANCE WITH PSE AND SNOPUD <br />REQUIREMENTS. COORDINATE CONSTRUCTION <br />ACTIVITIES AND SCHEDULE WITH UTILITY OWNER'S. SEE <br />SECTION 02 01 10 AND SECTION 02 01 20. <br />3.NORTON TERMINAL IMPROVEMENTS SHOWN BASED <br />ON BEST AVAILABLE RECORD INFORMATION. REMOVE <br />AND REPLACE IMPROVEMENTS AS REQUIRED TO <br />COMPLETE THE WORK. CONTRACTOR SHALL <br />DETERMINE THE ACTUAL LIMITS REMOVED BASED ON <br />THEIR APPROVED TRENCHING AND RESTORATION <br />PLANS. <br />4.SEE ADDITIONAL DEMOLITION REQUIREMENTS IN <br />SECTION 02 41 00. <br />5.SEE EX-2001 FOR ELECTRICAL, COMMUNICATION AND <br />POWER DEMO AND RELOCATION. <br />PLAN <br />SCALE: 1"=20"MATCHLINE SEE DRAWING CX-2001SCALE: <br />EXISTING PERIMETER FENCE <br />NTS <br />A <br />- <br />1 <br />2 <br />1 DEMOLISH EXISTING SECURITY FENCE WHERE REQUIRED <br />TO COMPLETE THE WORK. PORT SITE SECURITY MUST <br />BE MAINTAINED AT ALL TIMES. SEE ADDITIONAL <br />REQUIREMENTS PER SECTION 01 12 16 WORK <br />SEQUENCE. <br />2 REMOVE AND REPLACE EXISTING GATE IN KIND. <br />3 REMOVE AND REPLACE EXISTING NORTH GATE 2-15' <br />SWING GATES, 4' PERSONNEL GATE, AND 2-12' SWING <br />GATES IN KIND. <br />4 REMOVE AND REPLACE EXISTING 30' LOW-MAST LIGHT <br />POLES. COORDINATE WORK WITH CITY AND PORT. <br />5 PROTECT EXISTING PORT COMMUNICATION FACILITIES <br />IN PLACE WITHIN THE THE WORK AREA. COORDINATE <br />WORK AND REMOVAL AND REPLACEMENT OF <br />CONFLICTING CONDUIT OR OTHER ANCILLARY ITEMS <br />WITH CITY AND PORT. <br />6 PROTECT EXISTING PORT POWER FACILITIES IN PLACE <br />WITHIN THE THE WORK AREA. COORDINATE WORK <br />AND REMOVAL AND REPLACEMENT OF CONFLICTING <br />CONDUIT OR OTHER ANCILLARY ITEMS WITH CITY AND <br />PORT. <br />7 RESTORE EXISTING GRADE TO MATCH ORIGINAL <br />CONDITIONS. <br />8 REMOVE AND RESTORE EXISTING PAVEMENT PER <br />DETAIL 1 AND 2/CX-2011. <br />9 REMOVE AND REPLACE EXISTING 4' PERSONNEL GATE IN <br />KIND. <br />10 PROTECT IN PLACE OR REMOVE AND REPLACE EXISTING <br />2-12' SWING GATES IN KIND. <br />11 PROTECT IN PLACE 30' LOW-MAST LIGHT POLES IN KIND. <br />12 PROTECT IN PLACE OR REMOVE AND REPLACE FLAG <br />POLE IN KIND. <br />13 PROTECT IN PLACE EX SNOPUD DUCT BANK. LOCATE <br />PRIOR TO TRENCHING. ADJUST SHORING TO <br />ACCOMMODATE DUCT BANK AND MAINTAIN SUPPORT. <br />14 PORT TO RELOCATE EXISTING SECURITY CAMERA PRIOR <br />TO BEGINNING WORK. <br />15 REMOVE AND REPLACE EXISTING CURB AND <br />LANDSCAPING AS REQUIRED TO PROVIDE ACCESS <br />THROUGH SITE. PROVIDE TEMPORARY HAUL ROAD OR <br />ASPHALT. RESTORE TO PRE-CONSTRUCTION CONDITION <br />UPON COMPLETION OF THE WORK. <br />SCALE: <br />EXISTING NORTH GATE <br />NTS <br />B <br />-SCALE: <br />EXISTING SWING GATE <br />NTS <br />C <br />- <br />1 <br />4 <br />3 9 <br />12 <br />12 <br />9 10 <br />1 <br />11 <br />11 <br />14 <br />10 402020FEET0 <br />12/09/2025