My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2818 HEWITT AVE KATANA SUSHI 2016-09-28
>
Address Records
>
HEWITT AVE
>
2818
>
KATANA SUSHI
>
2818 HEWITT AVE KATANA SUSHI 2016-09-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/28/2016 2:52:37 PM
Creation date
9/28/2016 2:52:31 PM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
2818
Tenant Name
KATANA SUSHI
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Subject: Proposed Katana Sushi, 2818 Hewitt Ave, Everett <br /> October 14, 2013 <br /> Page 2 <br /> 11. Proper and adequate sneeze protection must be provided at the front counter sushi bar area. The <br /> sneeze guard must comply with NSF or equivalent standards. The sneeze protection must intercept <br /> the direct line between the customer's mouth and the food preparation area. On average the <br /> vertical distance from the customer's mouth to the floor is 4 feet six inches to 5 feet. Additional <br /> details are included on the enclosed information sheets. <br /> 12. All food service equipment (including the ventilation hood), both new and used, must be listed by <br /> the National Sanitation Foundation (NSF) or equivalent for its intended use. Used and new <br /> refrigeration must be capable of holding food at temperature of 41'F or below. <br /> 13. Extra wall protection is required on walls behind all sinks, including restroom handwash sinks, and <br /> food preparation counters and tables. A 16-inch high backsplash of plastic laminate, fiberglass- <br /> reinforced plastic or equal is acceptable. A backsplash higher than 16 inches is required on the wall <br /> behind counter top equipment taller than 16 inches. Floor to ceiling protection is required on the <br /> wall behind dishwashers. Wall protection behind mop sinks must cover the entire splash zone. <br /> Plastic coated hardboard is not acceptable. <br /> 14. All floors in the kitchen, food preparation, food service, food storage, and dishwashing areas must <br /> be surfaced with a durable, nonabsorbent, easily cleanable material. Expansion joints, seams, saw <br /> cuts and the like in concrete floors in all areas, including customer seating areas, must be filled and <br /> sealed so as to provide a smooth and cleanable surface. <br /> 15. The ceiling above the food preparation areas must be non-perforated, nonabsorbent, smooth and <br /> easily cleanable. <br /> 16. Cabinet shelving must be nonabsorbent, smooth and easily cleanable. (Self stick vinyl or other type <br /> surfaces are not acceptable) <br /> 17.All light fixtures in food preparation and storage areas must be provided with covers and <br /> shatterproof bulbs. Hot hold unit heat lamps must be provided with shatterproof bulbs. <br /> 18. Only one food preparation sink is indicated on the floor plan. Because of this, only vegetable <br /> preparation will be allowed at this sink. No rinsing or thawing under running water of raw meat, <br /> poultry, and/or seafood will be allowed without the installation of an additional and separate food <br /> preparation sink. If installed, the location of any additional food preparation sink must be approved <br /> prior to installation. The sink must be NSF listed or equivalent and have at least on integral <br /> drainboard. <br /> 19. This facility has a limited amount of reach-in refrigeration equipment. Reach-in refrigeration is not <br /> designed for cooling of hot foods. No advanced preparation of foods that require cooling and <br /> no cooling Cif leftover foods Nihil be allowed unless a walk-iii refrigerator or blast chiller <br /> (rapid temperature pull down refrigerator) is installed or other Health District approved <br /> cooling method is in place. Approval of any cooling method must be obtained prior to <br /> implementation of any cooling process. The request for consideration for cooling of foods must <br /> include submittal of the proposed menu and a HACCP for all proposed foods to be cooled. Approval <br /> of equipment used for cooling and approval of the proposed location of any cooling equipment must <br /> be obtained prior to installation of the equipment. Please note that if any approval for cooling of food <br /> is given the risk classification for the establishment will change to a high risk food establishment <br /> and an additional permit fee for the classification change will be charged. <br /> 20. The proposed amount of food storage refrigeration at this establishment is 94 cubic feet. This <br /> amount excludes the required food preparation refrigeration which is for immediate use food <br /> storage. The amount of food storage refrigeration at this facility does not meet the current minimum <br /> requirement of 144 cubic feet of storage refrigeration. Based upon the revised floor plans and <br />
The URL can be used to link to this page
Your browser does not support the video tag.