3207 HOYT AVE 2016-09-30
>
Address Records
>
HOYT AVE
>
3207
>
3207 HOYT AVE 2016-09-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/30/2016 8:41:26 AM
Creation date
9/30/2016 8:41:12 AM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
3207
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
63
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Structural • <br /> 1. The roof framing plan indicates existing framing above the living room. The plans and <br /> inspection consultation indicate a new header and other work done without permits at <br /> the ceiling level. Please verify that the altered ceiling construction is an adequate <br /> substitution for any ceiling framing or cross ties that may have been removed in the <br /> past. <br /> /2. Please verify that the structural calculations and structural plans submitted for the <br /> replacement and extension of the deck and the stairs connecting the deck to grade <br /> meet the 100 psf minimum requirement for an exit in a multifamily building, per IBC <br /> table 1607.1. <br /> L,'3. The supports for the existing egress stairs from the top apartment should be detailed on <br /> the drawings to be designed to support the stair loads to resist forces from wind, gravity <br /> and seismic loading, per IBC 1603.1. <br /> a. The foundation for the posts should be shown on the drawings to frost line, <br /> eighteen inches below grade. <br /> b. Positive attachment should be shown to secure the posts. <br /> )4Please submit framing drawings which show the structural supports of the floors and <br /> roof to clearly identify existing and new work per what has occurred in the field, and <br /> any resulting structural revisions required. <br /> a. Please reference details to the specific location on the framing plans. <br /> Construction <br /> L/ 1. The new roof on the expanded deck will trigger NFPA-13R sprinklers for the entire <br /> building, per IBC 903.2.8, as amended by the State of Washington. Please either <br /> remove the roof from the permit drawings, or identify the sprinkler requirement on the <br /> submittal. The new deck (unroofed) will not trigger this requirement for sprinklers. <br /> 2. A sleeping room should be identified and dimensioned in each apartment, per the <br /> minimum requirements of IPMC Section 404.4 and 404.6. <br /> 3. The living room in the first floor northwest corner apartment does not meet minimum <br /> requirements for an efficiency unit, per IPMC 404.6. Please revise the apartment layout <br /> to meet minimum room dimension requirements in IPMC Section 404, or revise the <br /> layout of the building from a fourplex to a triplex. The lower level plans were not <br /> reviewed in the previous fire restoration of the second level apartment, permit B1202- <br /> 005. <br /> O4Where the drywall has been removed and the assemblies are exposed, tested <br /> assemblies on the drawings should be targeted to the plans and sections to show <br /> minimum one hour horizontal and vertical separation of units, including sound isolation, <br /> per IBC sections 708.1 and 1207. <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8800 • Fax(425) 257-8882(/ <br />
The URL can be used to link to this page
Your browser does not support the video tag.