Laserfiche WebLink
CITY OF EVERETT SPECIAL PROVISIONS <br /> Provide continuous 6-inch diameter ductile iron pipe from the auxiliary gate valve <br /> at the main to the hydrant in accordance with COE Standard Drawing 507. <br /> ' Provide mechanical joint restraining glands conforming to 9-30.2(6) of these <br /> Special Provisions. <br /> 7-14.3(2)A Hydrant Restraints <br /> Revise the first paragraph in 7-14.3(2)A to read as follows: <br /> Restrain thrust created in short hydrant laterals of one pipe length or less <br /> ' using mechanical retainer glands at the auxiliary valve and hydrant fittings as <br /> shown in the COE Standard Drawing No. 507. For longer hydrant leads <br /> requiring two or more pipe lengths, Contractor may use field lock gaskets in <br /> lieu of mechanical joint restraint system to restrain the number of pipe joints <br /> between the auxiliary valve and the hydrant. <br /> 7-14.3(2)B Auxiliary Gate Valves and Valve Boxes <br /> Revise the first paragraph in 7-14.3(2)B to read as follows: <br /> Provide auxiliary gate valves and valve boxes in accordance with Section 7- <br /> 12 and COE Standard Drawing No. 507. <br /> 7-14.3(3) Reconnecting Existing Hydrants <br /> Revise the second paragraph in 7-14.3(5) to read as follows: <br /> Use mechanical retainer glands to restrain new hydrant lateral connection to <br /> ' hydrant fitting. <br /> 7-14.4 Measurement <br /> ' Delete all paragraphs of 7-14.4 and substitute the following: <br /> Bid items of Work completed pursuant to the Contract Documents will be measured as <br /> described in Division B — Bid Item Descriptions of these Special Provisions and <br /> ' Section 1-09 MEASUREMENT AND PAYMENT of the Standard Specifications. <br /> 7-14.5 Payment <br /> Delete all paragraphs of 7-14.5 and substitute the following: <br /> ' Payment for bid items of Work completed pursuant to the Contract Documents will be <br /> as described in Division B — Bid Item Descriptions of these Special Provisions and <br /> Section 1-09 MEASUREMENT AND PAYMENT of the Standard Specifications. <br /> 7-15 SERVICE CONNECTIONS <br /> 7-15.1 Description <br /> ' Delete the first paragraph of 7-15.1 and substitute the following: <br /> This Work consists of installing residential and commercial service connections from <br /> the main to the private line for the premises served. Include the meter box and meter <br /> ' setter for existing non-metered services. Include replacing existing meter boxes and <br /> meter setters as noted on the Plans and as directed by the Engineer. <br /> Work also includes abandoning existing service connection and service connection <br /> ' pipe in-place. <br /> Supplement 7-15.1 as follows: <br /> 7-15.1(1) Submittals <br /> (******) <br /> Provide Type 2 Working Drawings for all materials and Standard Plans. <br /> 7-15.2 Materials <br /> Delete first paragraph and material list of 7-15.2 and substitute the following: <br /> Water Main Replacement"Q" Division 7—WATER MAIN July 8, 2016 <br /> ' -Broadway <br /> WO No.—UP3612 SP -159 <br />