My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8925 AIRPORT RD MUKILTEO SCHOOL DISTRICT 2018-01-02 MF Import
>
Address Records
>
AIRPORT RD
>
8925
>
MUKILTEO SCHOOL DISTRICT
>
8925 AIRPORT RD MUKILTEO SCHOOL DISTRICT 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2020 3:35:52 PM
Creation date
11/22/2016 5:26:42 PM
Metadata
Fields
Template:
Address Document
Street Name
AIRPORT RD
Street Number
8925
Tenant Name
MUKILTEO SCHOOL DISTRICT
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
395
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
26. Section 16.76.030 of the �erett Municipal Code requires the installation <br /> of an automatic fir detection system in all buildings over 3,000 square <br /> feet. Such a system shall consist of any approved combination of heat <br /> and/or smoke detectors and shall be monitored by an approved central <br /> station. <br /> The fire alarm system plans shall be submitted to the fire department for <br /> review and approval prior to installation. It shall be installed under <br /> permit of the building department. , <br /> A complete trip test shall be performed in the presence of a fire <br /> iaspector prior to acceptance and issuance of a Certificate of Occupaacy. <br /> Call 259-8726 for further information. <br /> 27. Provide a sprinkler sqstem complying with UBC Standard 38-1 and/or NPPA <br /> Standard 13. <br /> Plans for any such system must be submitted to the Building Department and <br /> the �erett Fire Department for esamination and approval. Such plans must <br /> include plaas for the uaderground mains that will supply the sprinkler <br /> system. <br /> As of January 1991, sprinkler system permits are issued by the Building <br /> Departmeat. Plan review fees are r.ssessed by the Building Department. No <br /> fee is assessed by the Fire Departaent. <br /> Aboveground sprinkler piping Fust be hydrostatically teated as established <br /> in NFPA Standard 13. Underoround piping must be hydrostatically tested <br /> and flushed as established in NFPA Staadard 24 for private fire malns. <br /> All such tests must be witaessed by a Fire Department inspector. Call <br /> 259-8710 to make an appointment for iaspection. <br /> Contractors materials and test certificates must be submitted to the <br /> E�erett Fire Department prior to issuance of any Certificate of Occupancy. <br /> 28. Fire laaes must be provided as required in �erett Municipal Code 46.44. � <br /> Fire lanes must be identified by red curba with white stencil stating "NO � <br /> pARRING - FIRE LANE•" Vertical signa stating "NO PARRING - FIRE LANE - <br /> TOW AWAY ZONE" to be located as approved by the Fire Marshal. <br /> 29. Premises ID - Premises must be clearly identified by addresa at the street <br /> entrq. <br /> _ learl identified so as to be visible � <br /> 30. Building ID Each building must be c y ; <br /> and legible from the access road. � <br /> -17- <br />
The URL can be used to link to this page
Your browser does not support the video tag.