My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1520 112TH ST SW RAGE CAGE 2017-01-13
>
Address Records
>
112TH ST SW
>
1520
>
RAGE CAGE
>
1520 112TH ST SW RAGE CAGE 2017-01-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2017 8:00:34 PM
Creation date
12/14/2016 2:59:19 PM
Metadata
Fields
Template:
Address Document
Street Name
112TH ST SW
Street Number
1520
Tenant Name
RAGE CAGE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3) The soffit under the enclosed interior stairs should be shown as minimum one-hour fire-resistive <br />construction per Section 1009.6.3 (note that one layer of 5/8" Type X as called out on the plans is <br />not sufficient - a two layer assembly such as GA File No. RC 2601 could be used however). <br />4) The handrails on each side of the new stairs should be shown to continue horizontally at least 12 <br />inches beyond the top riser and continue along the slope for one tread depth beyond the bottom <br />riser. Section 1012.6 <br />5) The earth in Detail 1/3.0 should not be excavated below the top of the footings (exterior walls). <br />Section I �'09. ? <br />6) The plans indicate an access way cut in the crawlspace between the addition and existing <br />structures — it is not clear how access is gained into the crawlspace from outside of the <br />crawlspace however. Section 1209.1 <br />7) The location of attic access openings should be shown on the plans for attic spaces greater than <br />30 inches clear space. Section 1209.2 <br />8) The centerline of the toilets in both toilet rooms should be shown to be 16 to 18 inches from the <br />wall. ANSI A117.1-203 Section 604.2 <br />9) Grab bars in accordance with ANSI A117.1-2003 should be shown around the toilet in the toilet <br />room not marked as "ADA" as the room is being modified. The modified parts are therefore <br />required to comply with current accessible standards. Sections 3411.6 & 1109.2 <br />10)The walls within 2 feet of the water closets should be shown with smooth, hard nonabsorbent <br />surfaces adjacent to a height of 4 feet. Section 1210.2 <br />Please provide a response letter, which shows where each item in this correction letter is addressed <br />on the plan set. <br />Upon resubmission of the drawings, your application will be given priority and plan review will begin. <br />All required submittals must be of sufficient detail and contain sufficient information to ensure that the <br />proposed structure will be constructed in compliance with all adopted codes. <br />Sincerely, <br />` �� C��, <br />Tony�F� I��e <br />Building Official <br />:�, <br />