Laserfiche WebLink
. �_ � <br /> cunscructiu� <br /> 1. Wood used in the pazapets at the exterior walls should be shown as fire-retardant- <br /> treated. Section 503.4.3 <br /> 2. A detail should be provided for fireblocking of the interior walls where the ceil;ng <br /> and continuous walls inlersect. Section 08.1 I <br /> 3. The location of the roof drains should be shown on the plans,noted to the detail on <br /> Sheet A7.2. Section 1506 <br /> 4. A guardrail should be shown at the stairs adjacent to the glazing on the southem <br /> exterior wall. Section 509.1 <br /> 5. The plans should sliow that safety glazing is required in the panels adjacent to the <br /> doors where the neazest exposed edge of the glazing is within a 24 inch azc of either <br /> edge of the door and less than 60 inches above the walking surface. Section 2406.4, <br /> Item 6 <br /> 6. A detail should be provided for L�ie lateral uracing with compression struts for the <br /> suspended ceilin�. UBC Standazd 25-2,Table 25-A, Footnote 1 <br /> Exiting <br />, 1. The doors from the A-3 Occupancy to the exterior should not have a,lock or latch <br /> unless panic hardwaze devices are installed—to include doors#101 A, 101 B, 117A, <br /> 117B, 210, 211A&211C. Section 1007.2.4 <br /> 2. An occupant load sign should be shown for the A-3 Occupancy. Section 1007.2.6 <br /> 3. The doors from the A-3 occupancy should be specified to be on 180-degree hinges so <br /> as not to block the corridor by more than '/�of the required width. Section 1004.3.4.2 <br /> 4. Door l O1C should be shown as a 20-minute fire-resistive assembly for corridor <br /> protection. Doors 102, 111 C, 116 & 118A are shown as one-hour doors, but are only <br /> required to be 20-minute doors(based on comdor protection)we wili leave this to <br /> yourdiscretion. Section ]004.3.43.2.1 <br /> 5. The sidelite adjacent to Door l O1C should be shown as a 45-minute fire-resistive <br /> assembly. Section 1004.3.4.3.2.2 <br /> 6. Tlic listing for the one-hour floodceiling, roof/ceiling assembly for the corridor <br /> should b°shown on the plans. The fire protection for the ceiling above the stairs <br /> should also be clarified. Section 1004.3.43 <br />