Laserfiche WebLink
� <br /> I l. Pedestrian access must bc pro��ided as sho��m on the submitted site plan. , <br /> 12. The driveway access onto Broadway must be exit only/right turn only. <br /> 13. Access - O.K. as shown on the site plan reviewed. <br /> 14. When access to or within a structure or an area is unduly difficult because of�ecured <br /> openings or where immediate access is necessary for life saving or fire-fighting <br /> purposes, the Fire Department may recommend or require a key box to be installed in <br /> an accessible location. A rapid entry system may also be desirable in order to avoid <br /> unnecessary damage while making entry to any building during an emergency situation. <br /> Please call (425) 257-8123 for funher information. <br /> 15. Fire lanes shall be provided as required in Everett Municipal C;>de 46.44. Fire lanes <br /> shall be identified by red curbs with white srenciling stating "NO PARKING - FIRE <br /> LANE" and vertical signs stating "NO PARKING - FIRE LANE - TOW AWAY <br /> ZONE." I.ocation shall be approved by the Fire Marshal. <br /> 16. Premise identification - Premises shall be clearly identified by the correct address at the <br /> street entry. Buildings shall be clearly identified so as to be visible and legible from <br /> the access road. Individual apartments and suites, where applicable, shall be clearly <br /> and legibly identified from the access road. <br /> 17. Fire Hydrants - Locations as shown on the site plan are acceptable. <br />' 18. Based upon 15,222 square feet of Type V-N, sprinklered conswction, the fire flow <br /> requirement is 1,625 gpm. <br /> 19. Portable Fire Protection - A portable fire extinguisher with a minimum U.L. rating of <br /> 2-A:10-B:C shall be provided within 75 feet of travel on all Floors of each building <br /> during construction and prior to occupancy. <br /> 'L0. Fire Alarm System - An approved auromatic tire detection system shall be provided as <br /> required by Ciry Ordinance No. 1902-92, Chapter 16.76, of the Everett Municipal <br /> Code. <br /> Plans for such system shall be submitted to the Pire Marshal for review and approval <br /> prior to installation. Submittai shall include cut sheets of all equipment intended for. <br /> use. Appropriate trip tests, wimessed by a Fire Department inspector, shall be <br /> perfornied, along with a certificate of completion, prior to final acceptance of the <br /> system. <br /> Fire alarm systems shall be installed according to NFPA Standard 72. <br />