_ • ..u-. <br /> b <br /> <��,� <br /> Mr. Richard Heindel <br /> The Dykeman Architects <br /> May 21, 1993 <br /> Page 2 of 3 <br /> The calculated exit width of 196.5 inches must be divided approximately equally <br /> among the three (3) exits per Section 3303(b). <br /> 4. The corridor within the adminis[rative office area (Hall A115) serves an occupant <br /> load over 30 and must be of construction conforming to Section 3305(g) and Qi). <br /> 5. As a substantial remodel, this project must conform to Part II of Chapter 31 per � <br /> Secdon 3112(b). <br /> 50% of all public entries must be accessible per Section 3103(b)3. <br /> 6. The main entry is not accessible due to the use of locked doors and key card <br /> elevator access. <br /> 1'he elevator must be fully accessible to all of the public users of this public <br /> facility, not just to those students or faculty that may be �ssued keys. <br /> 7. The main entry stairs, interior and exterior, must be equipped with handrails and <br /> intermediate handrails as indicated in Section 3306(i). <br /> NOTE: O 1�E HANDRAIL ON EACH STAIR MUST COMPLY WITN THB HANDRAIL <br /> EX'i'ENSION REQUfREMENTS "IN TI�E DtRECTION OF STAIR tLU�I°. <br /> 8. An intermediate rail is required on the open sides of the main entry ramps per <br /> Section 3106(d)6. <br /> 9. The sides of the exterior main entry stair adjacent to the ramps must have landings <br /> at lhe top of the stair per Section 3306(g). <br /> NOTE: THIS IS AN AMENDMENT BY THE STATE BUILD[NC CODE. <br /> 10. Draftstops are requireci in the braced parapet areas, attic areas and floor/ceiling <br /> areas per Section 2516(�. <br /> 11. Exit stairs must be fully endosed per Section 3309(a). <br />