_._. , . <br /> 26. Fire Alarm Svstem: An appro��ed automatic fire detection system shall be provided as <br /> required by City Ordinance No. 1902-92, Chapter 16.76 of the Everett Municipal Code. <br /> klans for such system shall be submitted to the Fire Marshal for review and approval prior <br /> to installation. Submittal shall include cut sheets of all equipment intended for use. <br /> Appropriate trip test, witnessed by a Fire Department inspector, shall be perfortned, along <br /> with a certificate of completion, prior to final acceptance of the system. <br /> Fire alattr! system shall be installed according to ��IFPA Standard 72. <br /> Fire alarm system shall be installed under permit of the City of Everett Building <br /> Department. Electrical inspections and approval are required prior to calling for <br /> acceptance test. Call 254-8810 for permit information <br /> 27. The City of Everett prohibits outdoor burning. Therefore, outdoor buming for the <br /> purpose of dispcsing of construction deb�s or rubbish will not be permitted. <br /> 28. A fire hydrant is requirec� within 300 driving feet, but not closer than 50 feet, of every <br /> structure. Location of the hydrant(s) shall be approved by the Fire Marshall. <br /> Fire Avdrants: Locations as sho�vn on the site plan are acceptable. <br /> 29. Fire safety practices during construction must be in compliance with the Uniform Fire <br /> Code, 1985 Edition, Article 37, "Fire Safety During Construction." <br /> 30. Fire Sunnression (snrinklerl Svstem: An approved automatic suppression system shall be <br /> provided as required by Ciry Ordinance No. 1902-92, Chapter 16.76, of the Everett Municipal <br /> Code. <br /> Plans for any such system must be submitted to the Building and Fire Departments for review and <br /> approval prior to installation. Such plans shall include plans for the underground mains that will <br /> supply the sprinkler system. <br /> Aboveground sprinkler piping shail be hydrostatically tested as established in NFPA Standard 13. <br /> Underground piping shall be hydrostaticaliy tested and Flushed as established in NFPA Standard <br /> 24 for private fire mains. All such tests shall be witnessed by a Fire Department inspector. Call <br /> 259-8710 to make an �ppointment for inspection. <br /> Contractor's materials and test certificates shall be submitted to the Fire Department prior to <br /> issuance ofany Certificate ofOccupancy. Call 259-8720 for more information <br /> 31. Demolition of buildings shall be in compliance with the provisions of Uniform Fire Code, <br /> Section 87.105 "Fire safety during demolition," <br /> G <br />