My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5902 EVERGREEN WAY HOUSING HOPE 2018-01-01 MF Import
>
Address Records
>
EVERGREEN WAY
>
5902
>
HOUSING HOPE
>
5902 EVERGREEN WAY HOUSING HOPE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/12/2018 8:45:31 AM
Creation date
2/9/2017 9:35:37 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
5902
Tenant Name
HOUSING HOPE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
121
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> Subsurface Erploration, Grologic Kazard, and <br /> � Nousing Hvpe Pharr 1f Prefiminary Gtorechnical Er.qinerring Report <br /> Evenrr, N'arhingron D�sign Recommendationr <br /> � least 95 percent of ASTbf:D 1557. In addition, a 1.SH:1V line extending down from any <br /> footing must not daylight because sloughing or raveling may eventually undermine the footing. <br /> 'I'�us, footings should not be placed near the edge of steps or cuts in the bearing soils. <br /> � Anticipated settlement of footings founded as described above should be on the order of �4 <br /> � inch or less. However, disturbeci soil not removed from foot�ng excavatioas prior to footing <br /> placemrn[ could result in increaseci setdements. All footing areas should be inspected by AESI <br /> prior to pla�ing concrete to veri(y that the design beazing capacity of the soils has been attained <br /> � and tha[ construction conforms to the recommendations contained in this report. Such <br /> inspections may be required by the goveming municipaliry. Perimeter footin� drains should be <br /> provided as discussed under the section on Drainage Considerations. <br /> 1 . <br /> 12.0 RETAINING �VALL CONSIDERr1TIONS <br /> I �Ve recommend retaining, buttressing, or otherwise reinforcing the steep slope along the west <br /> marein of the proposed building area. Depending on planned finished floor elevations for the <br /> � south structure, it may be necessary to retain cut slopes along the south property as well. <br /> Several options are available for mitigation of shallow surficial landsliding on the west slope. <br /> � These include cast-in-place concrete retaining walls, suldier pile walls, soil nailing, and <br /> GeoeridT" reinforced modular block walls or rockeries. Of these op[ions, soldier piles and soil <br /> nailing w•ould likely be cost prohibitive. Reinforced fill with modular block (e.g., KeystoneT") <br /> I wall or rockery facings ��•ould likely be the least expensive option. Therefore, we have <br /> included eeneral'ued recommendations for conswction of cast-in-place walls and GeogridT" <br /> reinforced modular block walls or rockeries in the following sections. Once a wall rype is <br /> 1 chosen, we can assist the design team with more specific wall evaluation and design support. <br /> 12.1 I.ateral �Vall Pressures - <br /> � Al! backfill behind walls or around foundation units s6ould be placed as per our <br /> recommendations for structural fill and as described in this section of the report. Horizontally <br /> � backfilled walls that are free to yieid laterally at least 0.1 percent of their height may be <br /> designed using an equivalent fluid euual t�� 35 pounds per cubic foot (pe�. Fully restrained, <br /> � horizontally backfilled rigid walls that ca�mot yield should be designed for an equivalent Fluid <br /> of 50 pcf. If parkiag areas are adjacent to walls, a surcharge equivalent to 2 feet of soil should <br /> be added to the wall height in determining lateral design forces. Surcharges from the adjacent <br /> I building footings, heary cons[ruction equipment, or sloping ground must be added ro the above <br /> values if they encroach within the active soil wedge be6ind the wall. For permanent 2H:1V <br /> soil backslopes, we recommend design equivalent fluid pressures of 50 and 75 pcf for active <br /> i and at-rest conditions, respectively. <br /> � <br /> IFebruary 11, :fA2 ASSOCIATED E.1R7N SClENCE$ /NC. <br /> r SGH/fd�KEDI:+DA1�Pro��rn�:fl7/7�9�XE�WP.fVSK Pagc 12 I� <br /> ; /.�a <br />
The URL can be used to link to this page
Your browser does not support the video tag.